IC SI-series columns for carbonate eluent (Na2CO3/NaHCO3)

IC SI-52 4E HPLC Standard Column for oxyhalides analysis - Ion Chromatography - 5μm - 4.0mm I.D. x 250mm Length

Shodex Part Number: F6995260

The Ion Chromatography IC columns for anion analysis (suppressor method)

Related Products:

IC SI-92G Guard Cartridge Column - F6709626

Specifications:

Description IC SI-52 4E (PEEK) 250x4.0mm
Quantity 1 pc
Chemistry Producers Term Si
Base Material Polyvinyl alcohol
Mode of Separation Ion Exchange/Exclusion Chromatography
Plate Number (TP/column) ≥ 14,000
Functional Group Quaternary ammonium
Shipping Solvent 3.6 mM Na2CO3 aq.
Housing Material PEEK
Internal Diameter 4.0 mm
Length 250 mm
Brand IC
Particle Size 5 µm

SI-90 4E | SI-50 4E | SI-52 4E Features

  • Suitable for anion suppressor methods with sodium carbonate eluent
  • Suitable for the quantitative analysis of fluoride ion
  • SI-50 4E separates target inorganic anions from organic acids
  • SI-52 4E provides simultaneous analysis of oxyhalides and general inorganic ions
  • SI-52 4E Suitable for Anions - Ion exchange - Inorganic anions and oxyhalides analysis (Suppressor method: Sodium carbonate eluent)
  • Carbonate peak does not interfere with analysis

SI-35 Features

  • Columns for rapid analysis with suppressor method with sodium carbonate eluent
  • SI-35 4D provides rapid analysis of oxyhalides and general inorganic ions
  • SI-35 2B provides rapid analysis of general inorganic ions

IC SI-52 Possible Applications

  • Analysis of Chloride According to Japanese Testing Methods for Fertilizers (SI-52 4E)
  • Analysis of Organic Acids and Oxyhalides (SI-52 4E)
  • Analysis of Oxyhalides (SI-52 4E)
  • Analysis of Oxyhalides and Anions (SI-52 4E)
  • Analysis of Oxyhalides and Anions in Rain Water (SI-52 4E)
  • Analysis of Oxyhalides and Anions in River Water (SI-52 4E)
  • Analysis of Oxyhalides and Anions in Tap Water (SI-52 4E)
  • Calibration Curves for Oxyhalides (SI-52 4E)
  • Effects of Temperature on Retention Time (SI-52 4E)
  • Iodic Acid (SI-52 4E)
  • Rapid Analysis of Oxyhalides and Anions (SI-35 4D) (1)
  • Separation of Phosphate, Phosphtite and Hypophosphite (SI-52 4E)

Range of Ion Chromatography Columns (Anion Analysis)

Product Code Product Name Plate Number
(TP/column)
Functional Group Particle Size
(μm)
Column Size (mm)
I.D. x Length
Shipping Solvent
For non-suppressor method | Standard columns | Base Material: Polyhydroxymethacrylate | Housing Material: SUS
F6995243 IC NI-424 ≥ 5,000 Quaternary ammonium 5 4.6 x 100 8 mM 4-Hydroxybenzoic acid + 2.8 mM Bis-Tris
+ 2 mM Phenylboronic acid + 0.005 mM CyDTA aq.
F6709616 IC NI-G (guard column) Quaternary ammonium 5 4.6 x 10 8 mM 4-Hydroxybenzoic acid + 2.8 mM Bis-Tris
+ 2 mM Phenylboronic acid + 0.005 mM CyDTA aq.
F6995240 IC I-524A ≥ 2,000 Quaternary ammonium 12 4.6 x 100 2.5 mM Phthalic acid aq.
F6700400 IC IA-G (guard column) Quaternary ammonium 12 4.6 x 10 2.5 mM Phthalic acid aq.
For suppressor method (Sodium carbonate eluent) | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK
F6995244 IC SI-90 4E ≥ 5,000 Quaternary ammonium 9 4.0 x 250 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq.
F6709620 IC SI-90G (guard column) Quaternary ammonium 9 4.6 x 10 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq.
F6995245 IC SI-50 4E ≥ 10,000 Quaternary ammonium 5 4.0 x 250 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq.
F6709625 IC SI-50G (guard column) Quaternary ammonium 5 4.6 x 10 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq.
For oxyhalides analysis | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK
F6995260 IC SI-52 4E ≥ 14,000 Quaternary ammonium 5 4.0 x 250 3.6 mM Na2CO3 aq.
F6709626 IC SI-92G (guard column) Quaternary ammonium 9 4.6 x 10 3.6 mM Na2CO3 aq.
For oxyhalides rapid analysis | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK
F6995290 IC SI-35 4D ≥ 13,000 Quaternary ammonium 3.5 4.0 x 150 3.6 mM Na2CO3 aq.
F6709627 IC SI-95G (guard column) Quaternary ammonium 9 4.6 x 10 3.6 mM Na2CO3 aq.
For rapid analysis | Semi-micro columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK
F6995291 IC SI-35 2B ≥ 4,000 Quaternary ammonium 3.5 2.0 x 50 1.0 mM Na2CO3 + 2.0 mM NaHCO3 aq.
For anion suppressor method (Potassium hydroxide eluent) | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK 
F6999361 IC SI-36 4D ≥ 8,500 Quaternary ammonium 3.5 4.0 x 150 10 mM Na2SO4 aq.
F6709620 IC SI-90G (guard column) Quaternary ammonium 9 4.6 x 10 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq.

 

Guard filter for IC SI-35 2B | Removes sample-origin insoluble components.
F6709720 IC SI-2GF One holder and one filter
F6709730 IC SI-2GF filter 3 filters

 


  • Model: F6995260