Waters™ ACQUITY Premier BEH Shield RP18 VanGuard FIT Cartridge, 1.7 µm, 2.1 x 5 mm, 3/pk
Product Number: 186009503
Specifications:
Chemistry | C18 |
Separation Mode | Reversed Phase |
Particle Substrate | Hybrid |
pH Range Min | 2 pH |
pH Range Max | 11 pH |
Maximum Pressure | 18000 psi (1240 Bar) |
Endcapped | Yes |
Bonding Technology | Shield RP18 |
Silanol Activity | Low |
Particle Shape | Spherical |
Particle Size | 1.7 µm |
Endfitting Type | Parker-style |
Pore Size | 130 Å |
Format | VanGuard FIT Cartridge |
Surface Area | 185 |
System | UPLC |
Particle Technology | BEH |
Technique | LC |
USP Classification | L1 |
Inner Diameter | 2.1 mm |
Length | 5 mm |
Carbon Load | 17% |
eCord | Yes |
UNSPSC | 41115709 |
Brand | VanGuard |
Product Type | Guards |
Units per Package | 3 pk |
ACQUITY Premier cartridges work with the ACQUITY Premier VanGuard FIT columns. These fully integrated guard cartridges protect the analytical column from matrix and sample contaminants, extending column lifetime.
UPLC Column Protection – VanGuard Pre-Columns
Contamination resulting from the analysis of samples present within complex matrices, or that are particulate-laden, may result in reduced column lifetime if not properly addressed. VanGuard™ Pre-Columns are ideally suited for the physical and chemical protection of ACQUITY UPLC Columns. Directly compatible with UPLC pressures up to 18,000 psi [1241 bar], this ultra-low dispersion direct connect guard column is specifically engineered to preserve the lifetime of an ACQUITY UPLC Column without negatively impacting its separation performance.
ACQUITY Premier Columns
Stop looking and start seeing – no compromise required
ACQUITY Premier cartridges work with the ACQUITY Premier VanGuard FIT columns. These fully integrated guard cartridges protect the analytical column from matrix and sample contaminants, extending column lifetime.
Reduce the risks associated with unpredictable chromatography with ACQUITY Premier Columns with MaxPeak High Performance Surfaces (HPS) Technology, which allow you to see and do more by reducing analyte/surface interactions.
With Waters ACQUITY Premier Columns, chromatographers can harness the separation efficiency improvements and increased flow rates of ultra-performance liquid chromatography (UPLC) technology, improving analyte resolution, sensitivity, business productivity, and profitability. As the next evolution in the ACQUITY UPLC Column family, ACQUITY Premier Columns are built on the industry-leading sub-2-µm particle technologies from Waters you trust.
- Reduces column conditioning and passivation for higher productivity
- Increases reproducibility from analysis to analysis, for more confidence in analytical results
- Reduces non-specific absorption for increased sensitivity, improved peak shape, and easier analyte integration
- Provides superior separation speed, sensitivity, and resolution with best-in-class column efficiency
- 3 UPLC particles of various substrate technologies, including Ethylene Bridged Hybrid (BEH), High Strength Silica (HSS), and Charged Surface Hybrid (CSH)
- Reversed-phase and HILIC stationary phases, including C18, Embedded-Polar, and Amide
- Application-specific column chemistries for peptides, proteins, oligonucleotides, and glycan analysis
- Prolonged column lifetimes with VanGuard FIT Columns, and easy-to-use, all-in-one guard/column design
Recommended Use: For increased sensitivity, improved peak shape, and less column equilibration time in methods development.
ACQUITY Premier BEH Shield RP18 Columns
- Contains an embedded-polar group combined with the hydrophobicity of C18
- Complementary selectivity to a C18 column
- Enhanced peak shape for basic compounds
- Compatible with 100% aqueous mobile phases
- High efficiency
ACQUITY BEH Shield RP18 columns complement the ACQUITY BEH C18 and C8 phases and provide a necessary and powerful tool for HPLC method development. The embedded carbamate group in the bonded phase ligand provides alternate selectivity, especially for phenolic compounds compared to straight chain alkyl columns.
Embedded polar group reversed-phase LC columns contain stationary phases that combine the hydrophobicity of an alkyl ligand with the hydrophilicity of an embedded polar group. Features of embedded polar group columns include alternate selectivities as compared to alkyl chain LC columns, excellent peak shape for bases and aqueous mobile- phase compatibility. ACQUITY UPLC BEH Shield RP18 columns are designed to provide selectivities that complement the ACQUITY UPLC C18 and C8 phases.
ACQUITY UPLC Shield RP18 columns combine Waters patented Shield Technology with BEH Technology by incorporating an embedded carbamate group into the bonded phase ligand. The alternate selectivity and excellent peak shape from the embedded polar group ligand, when combined with the wide pH range and ultra-efficiency of the 1.7 μm BEH particle, provide a powerful tool for UPLC method development.
BEH (Ethylene Bridged Hybrid) Technology
In 1999, Waters launched the XTerra family of HPLC columns featuring first generation hybrid particle technology (HPT). HPT enabled XTerra columns to become one of the most successful column products in the history of Waters. In HPT, the best properties of inorganic (silica) and organic (polymeric) packings are combined to produce a material that has superior mechanical strength, efficiency, high pH stability and peak shape for bases. The first generation methyl hybrid particles of XTerra columns did not possess the mechanical strength or efficiency necessary to fully realize the potential speed, sensitivity and resolution capabilities of UPLC technology. Therefore, a new pressure-tolerant particle needed to be created. A new, second generation hybrid material was developed which utilizes an ethylene bridged hybrid (BEH) structure. Compared to the first generation methyl hybrid particle of XTerra columns, the BEH particle of ACQUITY UPLC BEH columns exhibits improved efficiency, strength and pH range. BEH Technology™ is a key enabler behind the speed, sensitivity and resolution of UPLC separations.
ACQUITY UPLC columns
ACQUITY UPLC columns are the most technologically advanced LC columns ever created and are the only columns designed, tested and certified to withstand the pressures of UPLC Technology. Based upon the highly efficient 1.7 µm Bridged Ethyl Hybrid (BEH) particles and 1.8 µm High Strength Silica (HSS) particles, these columns are the first and only columns that allow separation scientists to achieve maximum speed, sensitivity and resolution without compromise. The particles and chemistries of the ACQUITY UPLC column family were carefully chosen to produce the ideal combination of ultra-performance efficiencies, wide pH range and complementary selectivities. ACQUITY UPLC BEH columns and ACQUITY UPLC HSS columns are the only columns recommended for use with ACQUITY UPLC Systems.
There is more to creating a UPLC particle than synthesizing a small particle. Many HPLC particles do not possess the mechanical stability and structural integrity to withstand UPLC operating pressures (e.g., 15000 psi/1000 bar). Why is pressure tolerance important? In order to realize the efficiency gains of sub-2 μm particles, the ability to routinely operate at higher linear velocities (e.g., higher flow rates) is required. These higher linear velocities combined with small, sub-2 μm particles result in higher operating backpressures. Waters has created two highly efficient, pressure-tolerant UPLC particles: the 1.7 μm Ethylene Bridged Hybrid (BEH) particle and the 1.8 μm High Strength Silica (HSS) particle.
The first ACQUITY UPLC particle created was the 1.7 μm Ethylene Bridged Hybrid (BEH) particle. This second generation hybrid particle is one of the key enablers behind UPLC technology and is available in five column chemistries: C18, C8, Shield RP18, Phenyl and HILIC. Because this is a hybrid particle, a wider usable pH range (up to pH 1-12) makes method development faster and easier. BEH particles are also available in HPLC particle sizes (2.5, 3.5, 5 and 10 μm) in the XBridge family of HPLC columns, thus allowing seamless transfer between HPLC and UPLC separations.
Related Products:
- 600000668CV - LCMS Certified Clear Glass 12 x 32 mm Screw Neck Vial, with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk
- 186009500 - ACQUITY Premier BEH Shield RP18 Column with VanGuard FIT, 1.7 µm, 2.1 x 50 mm, 1/pk
- 186009501 - ACQUITY Premier BEH Shield RP18 Column with VanGuard FIT, 1.7 µm, 2.1 x 100 mm, 1/pk
- 186009502 - ACQUITY Premier BEH Shield RP18 Column with VanGuard FIT, 1.7 µm, 2.1 x 150 mm, 1/pk
- Model: 186009503
- Manufactured by: Waters