ALL-IN-ONE GC AUTOSAMPLER
2850T: All-in-one GC Autosampler with Fibre (Fiber) Cleaning Device
For headspace analysis, liquid sample injection and SPME
The 2850T combines the functions of an autosampler for liquid, static headspace and SPME in a single device. Because of its flexibility, the 2850T can easily be installed on all the GC and GC/MS systems available on the market.
Key Features
Any GC - Any GC/MS
It can easily be installed on all the GC and GC/MS systems available on the market with no requirement to modify the GC inlet or GC oven. As a multifunctional autosampler, it offers near-to-zero bench requirements, maximised productivity and a lower total cost of ownership compared to multiple autosamplers feeding the same GC.
Intuitive to operate
2850T is an all-in-one autosampler made simple: neither too expensive nor too complex to operate. Having no need for macro programming means immediate, simple and intuitive usage. The high-quality touchscreen provides easier system accessibility and usability for both novices and experienced users. For routine analyses, the 2850 features one-touch operation: after loading the sample, you just need to push the START button. Besides the touch screen, the 2850T can be also controlled by a PC with optional HTA Autosampler Manager software.
Only 5 minutes to switch...injection technique or GC
5 minutes to switch between modalities, 5 minutes to move between GCs. 2850T allows for quick and easy switching from one application to another on the same GC workstation. Regardless if your samples are processed in headspace, liquid, or SPME mode, or if the method requires split, splitless or on-column injection, your new instrument set-up is ready in a few minutes.
Smart Technologies make the difference
2850T benefits from a unique portfolio of technologies that have been put together by our R&D team to make your user experience amazing. For your headspace analysis we provide vial leakage check functionality. For your liquid sample analysis, we offer SyringeID, to prevent syringe volume mismatch error and to keep track of the syringe consumption. When coupled to Mass Detectors we have optimized methods to reduce operation costs and to improve results.
Empowered by Artificial Intelligence (AI)
AI brings intuitiveness and superior performances to laboratories. By AI functionalities within 2850T we offer: self-diagnostic tests that enable predictive maintenance strategies, continuous optimization of the workflow, extended flexible working style, automated consumables tracking. Furthermore we dramatically simplify connection with service by usage of dynamic on-screen QR code.
TECHNICAL SPECIFICATIONS
GENERAL FEATURES | LIǪUID | ||
Maintenance: | preventive counters; system performance test for headspace 4 and liquid syringes; predictive maintenance functionalities by AI LAN and TTL | Syringe volume: | 0.5, 1, 5, 10, 25, 50 and 100μL |
Electrical control: | LAN and TTL | SyringeID 1: | optional |
Target illumination: | yes | Filling | |
Barcode Reader: | optional | Sample volume: | as low as a step of 0.1μL |
Tray capacity | Air volume: | as low as a step of 0.1μL | |
Headspace/SPME: | 42 vials (20ml); optional: 6 and 10ml | Filling speed: | 1-100μL/sec |
Liquid: | 121 vials (2ml) | Viscosity delay: | 0-15s |
Oven | Bubble elimination: | up to 15 pull up strokes | |
Oven positions: | 6 | Injection | |
Oven positions: | ambient; 40-170°C | Injection speed: | 1-100μL/sec |
Shaking method: | orbital | Pre and post injection delay: | 0-99s |
Shaker speed: | from very low to very high | Washing | |
Shaking cycles: | on/off 0-9.9min | Type: | pre-injection, sample, post-injection |
Incubation time: | 0-999min | Solvent capacity: | 6x10ml vials |
Physical features | Mode: | single or double wash | |
Dimensions (W x H x D) 3: | 330 x 640 x 320 mm | Internal standard technique | |
Weight: | 10kg | IS volume: | as low as a step of 0.1μL |
Power supply: | 100-240±10%Vac; 50-60Hz; 120W | Air gap volume: | as low as a step of 0.1μL |
Mode: | 1 or 2 air gaps | ||
HEADSPACE | |||
Syringe volume: | 2.5ml (standard); optional: 1ml | ||
Cleaning system: | inert gas flush (inlet: 1/8”; max pressure: 2bar) | ||
Vial Leakage Check 1: | yes | ||
SPME 5 | |||
Extraction mode: | liquid phase/headspace vapours | ||
Fibre type: | 10mm, 20mm, sealed tip | ||
Fibre cleaning station | |||
Temperature: | 210-300°C | ||
Cleaning system: | inert gas flush (inlet: 1/8”) | ||
Sampling and injection | |||
Syringe temperature: | ambient; 40–150°C | ||
Sample volume: | steps of 0.01ml | ||
Sample homogenizatin: | up to 15 0.1– | ||
Sample speed: | 100ml/min | ||
PC REǪUIREMENTS FOR HTA MONITOR | |||
Software: |
| ||
Hardware: |
|
1 Patented technology
3 Tray and oven cover in closed position
4 An optional accessory required
5 Optional, supplied as a separate kit
- Model: 2850T
- Manufactured by: HTA