Waters™ ACQUITY Premier Protein SEC Column, 250Å, 1.7 µm, 4.6 x 300 mm Method Validation Kit, 3/pk
Product Number: 176004806
Specifications
Chemistry | SEC |
Separation Mode | SEC |
Particle Substrate | Hybrid |
pH Range Min | 2.5 pH |
pH Range Max | 8 pH |
Temperature Limits | 60 C |
Maximum Pressure | 11000 PSI (759 bar) |
Endcapped | No |
Bonding Technology | BEH-PEO |
Silanol Activity | Low |
Molecular Weight Range Min | 10000 |
Molecular Weight Range Max | 650,000 |
Particle Size | 1.7 µm |
Endfitting Type | Parker-style |
Pore Size | 250 Å |
QC Tested | Protein |
Format | Online Column |
Surface Area | 174 |
System | UPLC |
Particle Technology | BEH |
Technique | LC |
USP Classification | L33, L59 |
Inner Diameter | 4.6 mm |
Length | 300 mm |
Carbon Load | 12% |
eCord | Yes |
UNSPSC | 41115709 |
Application | Protein |
Brand | ACQUITY UPLC |
Product Type | Columns |
Units per Package | 1 pk |
ACQUITY Premier Protein SEC 250Å, 1.7 µm Columns help scientists obtain reliable protein size variant separations (10,000 to approx 650,000 Daltons) via the synergistic coupling of Waters MaxPeak Premier High Performance Surfaces and novel BEH-PEO Particle technologies. These advancements in SEC column hardware and SEC particle technology work to minimize non-desired secondary ionic or hydrophobic interactions between proteins and the column to minimize costly method development work by allowing chromatographers to use a “generic” or “platform-type” method for many samples. Note: This Method Validation Kit (MVK) contains (3) columns from (3) different batches and aslso includes, at no addtional cost, (3) vials of Waters mAb Size Variant Standard (p/n: 186009429) Also note that for optimal SEC separation performance, this column is designed for use in UPLC SEC applications with an appropriate low LC system volume.
ACQUITY UPLC Method Validation kits
ACQUITY UPLC Method Validation kits provide three batches of chromatographic media (derived from different base particles) to assess the quality, reliability and consistency of your analytical method.
ACQUITY Premier Columns
Stop looking and start seeing – no compromise required
Reduce the risks associated with unpredictable chromatography with ACQUITY Premier Columns with MaxPeak High Performance Surfaces (HPS) Technology, which allow you to see and do more by reducing analyte/surface interactions.
With Waters ACQUITY Premier Columns, chromatographers can harness the separation efficiency improvements and increased flow rates of ultra-performance liquid chromatography (UPLC) technology, improving analyte resolution, sensitivity, business productivity, and profitability. As the next evolution in the ACQUITY UPLC Column family, ACQUITY Premier Columns are built on the industry-leading sub-2-µm particle technologies from Waters you trust.
- Reduces column conditioning and passivation for higher productivity
- Increases reproducibility from analysis to analysis, for more confidence in analytical results
- Reduces non-specific absorption for increased sensitivity, improved peak shape, and easier analyte integration
- Provides superior separation speed, sensitivity, and resolution with best-in-class column efficiency
- 3 UPLC particles of various substrate technologies, including Ethylene Bridged Hybrid (BEH), High Strength Silica (HSS), and Charged Surface Hybrid (CSH)
- Reversed-phase and HILIC stationary phases, including C18, Embedded-Polar, and Amide
- Application-specific column chemistries for peptides, proteins, oligonucleotides, and glycan analysis
- Prolonged column lifetimes with VanGuard FIT Columns, and easy-to-use, all-in-one guard/column design
Recommended Use: For increased sensitivity, improved peak shape, and less column equilibration time in methods development.
ACQUITY Premier Protein SEC 250 Å Guards and Columns
- Sub-2-μm particle columns for UPLC separations
- 250 Å pore size
- High throughput & resolution SEC separations of biomolecules ranging from 10,000 to 650,000 Daltons on low dispersion UPLC Systems
- Available SEC Guard Columns to extend analytical SEC Column life
- Significantly reduce non-desired ionic and hydrophobic secondary interaction for desired SEC platform methods with MaxPeak Premier Technology and BEH-PEO SEC particle technology
SEC Columns
Size-based separations of peptides, proteins, and viral vectors
Get unmatched batch-to-batch reproducibility with the wide range of Waters Size-Exclusion Chromatography (SEC) Columns and standards for protein and peptide characterization.
SEC is a powerful technique for aggregate and fragment analysis in the research, development, and manufacturing of biotherapeutic proteins, such as insulin and monoclonal antibodies (mAb).?With SEC, also known as gel filtration, you can separate proteins based on their size (hydrodynamic radii versus absolute molecular weight) in solution, with larger sized species eluting before smaller proteins.
The?pore size?and?volume of the SEC particles?used in the packed column drives this isocratic based technique, so the column you choose matters.?As the molecular weight of the proteins of interest increases, SEC columns with comparatively larger pore size particles are selected.
ACQUITY UPLC columns
ACQUITY UPLC columns are the most technologically advanced LC columns ever created and are the only columns designed, tested and certified to withstand the pressures of UPLC Technology. Based upon the highly efficient 1.7 µm Bridged Ethyl Hybrid (BEH) particles and 1.8 µm High Strength Silica (HSS) particles, these columns are the first and only columns that allow separation scientists to achieve maximum speed, sensitivity and resolution without compromise. The particles and chemistries of the ACQUITY UPLC column family were carefully chosen to produce the ideal combination of ultra-performance efficiencies, wide pH range and complementary selectivities. ACQUITY UPLC BEH columns and ACQUITY UPLC HSS columns are the only columns recommended for use with ACQUITY UPLC Systems.
There is more to creating a UPLC particle than synthesizing a small particle. Many HPLC particles do not possess the mechanical stability and structural integrity to withstand UPLC operating pressures (e.g., 15000 psi/1000 bar). Why is pressure tolerance important? In order to realize the efficiency gains of sub-2 μm particles, the ability to routinely operate at higher linear velocities (e.g., higher flow rates) is required. These higher linear velocities combined with small, sub-2 μm particles result in higher operating backpressures. Waters has created two highly efficient, pressure-tolerant UPLC particles: the 1.7 μm Ethylene Bridged Hybrid (BEH) particle and the 1.8 μm High Strength Silica (HSS) particle.
The first ACQUITY UPLC particle created was the 1.7 μm Ethylene Bridged Hybrid (BEH) particle. This second generation hybrid particle is one of the key enablers behind UPLC technology and is available in five column chemistries: C18, C8, Shield RP18, Phenyl and HILIC. Because this is a hybrid particle, a wider usable pH range (up to pH 1-12) makes method development faster and easier. BEH particles are also available in HPLC particle sizes (2.5, 3.5, 5 and 10 μm) in the XBridge family of HPLC columns, thus allowing seamless transfer between HPLC and UPLC separations.
Related Products
- ACQUITY Premier BEH Phenyl VanGuard FIT Cartridge, 1.7 µm, 2.1 x 5 mm, 3/pk - 186010341
- ACQUITY Premier BEH Phenyl Column, 1.7 µm, 2.1 mm X 50 mm, 1/pk - 186010336
- TruView pH Control LCMS Certified Clear Glass, 12 x 32 mm, Screw Neck Vial, with Cap and preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk - 186005666CV
- Neutrals QC Reference Material - 186006360
- 96-well Sample Collection Plate, 700 µL Round well, 25/pk - 186005837
- Model: 176004806
- Manufactured by: Waters