Welcome, Sign In First time visitor? Create a New Account
Your cart is empty

PAL System Modules

 

Comprehensive Sample Preparation Capabilities

For precise sample preparation you need the right tools and modules. Discover the best modules available for sample preparation and injection workflows.

Please contact our specialist team to discuss your requirements and laboratory needs!

PAL System Thermal Mixer for Shaking and Heating of Well Plates - PAL3-ThermalMixer

PAL Thermal Mixer, for shaking and heating of well plates.
Only compatible with PAL table mounted.
Temperature range 30-100°C
Mixing 0-2000 rpm

Requires FW 4.1 or higher

Adapter needs to be ordered separately:
PAL3-TM-Adap-ABGene: Adapter for Abgene™ 96 Well 0.8 ml Polypropylene DeepWell™ (Thermo part number AB0765)
PAL3-TM-Adap-EPP: Adapter for Eppendorf® Deepwell plates, standard, 96 wells, conical bottom colorless wells, capacity 1000 µl (Eppendorf part number 0030501209)

Wash Cup Setup, incl. 2-Channel Volumetric Pump, Wash Cup PEEK, Tubing, Solvent Bottles
PAL3-ActWashCup-2ChV

Wash Cup Setup, consisting of:

1 pc 2-Channel Volumetric Pump incl. holder and PAL Bus Connection cable
1 pc Wash Cup PEEK
1 pc PFA Transfer tube 1/16" for up to 850 mm
2 pcs Solvent Bottle 1000 ml
2 pcs Solvent Inlet Tubing Kit PFA

Attention: For x-rails longer than 850 mm PAL3-TubeLC/MS-VP-X is required (to be ordered separately)

Requires PAL Series II with FW 4.12 or higher

PAL System Agitator - PAL3-Agitator

• For the incubation and agitation of samples
• 6 positions for 20 ml vials
• Temperature range 40 - 200 °C
• Agitation speed 250 - 750 rpm
• Optional adapters for 2 ml or 10 ml vials

Requires firmware version 1.3.0 or higher

PAL System Barcode Reader - PAL3-BarcodeReader

• Reads horizontal 1D barcodes
• Two scanners allow identification of vials irrespective of position of the barcode
• Works with 2 ml / 10 ml / 20 ml vials

Requires firmware version 1.3.0 or higher

PAL System Combi Centrifuge for 2/10/20 ml Vials - PAL3-Centrifuge-Combi

• For the efficient centrifugation in automated workflows (e.g. protein precipiation, phase separation)
• Control through many Chromatographic Data Systems
• Relative centrifugal force: 2000 x g with centrifuge Combi
• Vial format: 2 ml (4 vials,) 10 ml / 20 ml (2 vials)

Requires firmware versions:

3.1.19.1 or higher for PAL3 Series II
2.5.57.2 or higher for PAL3 series with iMX6 board

PAL Sample Control users need PAL Sample Control SW Version 2.5 or higher

PAL System Heatex Stirrer - PAL3-HeatexStirrer
• For powerul mixing and heating in sample prep and SPME Arrow
• Temperature range 40 ° - 150 °C
• Stirring speed up to 1600 rpm (i.e. 200 cycloidal loops)
• Optimized for 20 ml vials (for 10 ml vials special adapters are required)
• Requires firmware version 2.3 or higher
• Use in combination with existing PAL3-Agitator
PAL System Vortex Mixer - PAL3-VortexMixer

• For efficient mixing (dilution / extraction)
• Standard vial sizes: 2 ml / 10 ml / 20 ml
• 1 additional slot for custom specific vials
• Provides efficient mixing with up to 2000 rpm

Requires firmware version 1.3.0 or higher

PAL System Decapper - PAL3-Decapper

• Opens/closes 2, 10, 20 ml screw cap vials without any change of hardware (no adapters required)
• Defined torque guarantees the reproducible and leak-tight closing of headspace vials

requires FW Version 2.4 or higher

PAL System Dilutor Single Option - PAL3-DilutorSingle

For the efficient and accurate addition of larger amounts of liquids

consisting of:

1 pc Dilutor Single
1 pc PAL Bus Connection cable
1 pc Dilutor Tool
1 pc Dilutor Syringe 1 ml
1 pc PFA Transfer Tube 1/16"
1 pc Solvent Bottle 1000 ml
1 pc Solvent Inlet Tubing Kit PFA

Requires firmware version 2.1.0 or higher

PAL System SPME Arrow Conditioning Module - PAL3-SPME-ArrowCond

For the conditioning of SPME Arrows and SPME Fibers prior to sample enrichment, max. 350 °C

• Position for automated conditioning
• Position for manual pre-conditioning
• Automated purge gas valve
• Manual gas valve for pre-conditioning

Requires firmware version 2.3 or higher

Flow Cell for PAL System - PAL3-FlowCell
PAL System Flow Cell to accommodate up to 6 flow cells
consisting of:

1 pc Holder 88 mm
1 pc Flow-Cell stainless steel 316 with connectors Swagelok 1/4"
5 pcs Inlet septa
PAL System Standard Wash Module - PAL3-WashStd
• Wash Module for low volume injections
• 4 x 10 ml Wash solvent vials
• 1 x 10 ml Waste vial
• Optional waste port adapter to connect a tube to a waste bottle
PAL Fast Wash Module

For minimized carryover

cleans syringes of gauges 19 to 26 and supports two different wash solvents (aqueous and organic)

PAL HF Fast Wash Module

For flow rates up to 40 ml/min.

cleans syringes of gauges 19 to 26 and supports two different wash solvents (aqueous and organic)

PAL System Wash Module for LC/MS Tool - PAL3-WashLCMS

PAL System Wash Module for LC/MS Tool
consisting of:

1 pc Wash Module with two wash positions and one waste position

Passive Wash Module for use with LC/MS Tools or Dilutor Tools

Requires FW 2.0.x or higher

PAL System Large Wash Module - PAL3-WashLarge

Wash Module for large volume injections

consisting of:

2 pcs 100 ml Solvent container (glass) with septum cap
1 pc Waste Port with tubing olive to connect waste bottle

PAL System Solvent Module - PAL3-SolventModule
PAL Solvent Module with 3 pcs 100 ml Solvent Bottles (glass) with septum cap.

For large solvent demands, e.g. for the addition of larger volumes of solvents or serial dilutions
PAL System Tray Holder for Racks or Plates - PAL3-Trayholder

PAL System Tray Holder for the storage of:

3 pcs Standard microtiter plates
3 pcs Deepwell plates
3 pcs VT15, VT54 or VT70 racks
1 pc R60 rack
or combinations

PAL System Tray Cooler - PAL3-TrayCooler

PAL System Tray Cooler for the storage of

3 pcs Standard microtiter plates
3 pcs Deepwell plates
3 pcs VT15, VT54 or VT70 racks
or combinations

• Under defined temperature conditions between 4 °C and 40 °C
• Depending on tray type inserts are required
• Including power supply and cables

Requires firmware version 3.1.21 or higher

PAL System Tray Holder and Sample Tray - PAL3-LiqCooler

Tray Holder and Sample Tray

• Temperature range between 4°C- 70°C
• For up to 32 vials of 10/20 ml
• External circulator bath for heating/cooling not included

PAL Stack for 6DW and 12MT

For the storage of racks or plates at room temperature

allows to store samples with light sensitive compounds

PAL Peltier Stack for 2DW, 6DW and 12MT

For the storage of racks or plates under defined temperature conditions

temperature range between 4 °C and 40 °C

PAL System Valve Drive for Valco valves - PAL3-ValveDrive-V

PAL System Valve Drive (without valve) for Valco Valves for applications like sample injection, column switching for online LC-LC/MS or online SPE-LC/MS, Multiplexing, column selection and many more.

Consisting of:

1 pc Valve Drive
1 pc PAL BusConnection cable

• Injection port bottom sensing minimizes carryover
• Constant force technology to reduce dead volume during Injection process
• UHPLC/HPLC: up to 50% faster switching times for optimum
• System performance and prolonged column life time
• Stackable design to reduce the space required
• Huge flexibility to arrange Multiple valve solutions
• The Fast Wash Module is also stackable below a Valve Drive

Requires firmware version 1.4.0 or higher

  

There are no products to list in this category.