| PAL System Thermal Mixer for Shaking and Heating of Well Plates - PAL3-ThermalMixer | |
![]() | PAL Thermal Mixer, for shaking and heating of well plates. Requires FW 4.1 or higher Adapter needs to be ordered separately: |
| Wash Cup Setup, incl. 2-Channel Volumetric Pump, Wash Cup PEEK, Tubing, Solvent Bottles PAL3-ActWashCup-2ChV | |
![]() | Wash Cup Setup, consisting of: Attention: For x-rails longer than 850 mm PAL3-TubeLC/MS-VP-X is required (to be ordered separately) Requires PAL Series II with FW 4.12 or higher |
| PAL System Agitator - PAL3-Agitator | |
![]() | • For the incubation and agitation of samples Requires firmware version 1.3.0 or higher |
| PAL System Barcode Reader - PAL3-BarcodeReader | |
![]() | • Reads horizontal 1D barcodes Requires firmware version 1.3.0 or higher |
| PAL System Combi Centrifuge for 2/10/20 ml Vials - PAL3-Centrifuge-Combi | |
![]() | • For the efficient centrifugation in automated workflows (e.g. protein precipiation, phase separation) Requires firmware versions: PAL Sample Control users need PAL Sample Control SW Version 2.5 or higher |
| PAL System Heatex Stirrer - PAL3-HeatexStirrer | |
![]() | • For powerul mixing and heating in sample prep and SPME Arrow • Temperature range 40 ° - 150 °C • Stirring speed up to 1600 rpm (i.e. 200 cycloidal loops) • Optimized for 20 ml vials (for 10 ml vials special adapters are required) • Requires firmware version 2.3 or higher • Use in combination with existing PAL3-Agitator |
| PAL System Vortex Mixer - PAL3-VortexMixer | |
![]() | • For efficient mixing (dilution / extraction) Requires firmware version 1.3.0 or higher |
| PAL System Decapper - PAL3-Decapper | |
![]() | • Opens/closes 2, 10, 20 ml screw cap vials without any change of hardware (no adapters required) requires FW Version 2.4 or higher |
| PAL System Dilutor Single Option - PAL3-DilutorSingle | |
![]() | For the efficient and accurate addition of larger amounts of liquids Requires firmware version 2.1.0 or higher |
| PAL System SPME Arrow Conditioning Module - PAL3-SPME-ArrowCond | |
![]() | For the conditioning of SPME Arrows and SPME Fibers prior to sample enrichment, max. 350 °C • Position for automated conditioning Requires firmware version 2.3 or higher |
| Flow Cell for PAL System - PAL3-FlowCell | |
![]() | PAL System Flow Cell to accommodate up to 6 flow cells consisting of: 1 pc Holder 88 mm 1 pc Flow-Cell stainless steel 316 with connectors Swagelok 1/4" 5 pcs Inlet septa |
| PAL System Standard Wash Module - PAL3-WashStd | |
![]() | • Wash Module for low volume injections • 4 x 10 ml Wash solvent vials • 1 x 10 ml Waste vial • Optional waste port adapter to connect a tube to a waste bottle |
| PAL Fast Wash Module | |
![]() | For minimized carryover cleans syringes of gauges 19 to 26 and supports two different wash solvents (aqueous and organic) |
| PAL HF Fast Wash Module | |
![]() | For flow rates up to 40 ml/min. cleans syringes of gauges 19 to 26 and supports two different wash solvents (aqueous and organic) |
| PAL System Wash Module for LC/MS Tool - PAL3-WashLCMS | |
![]() | PAL System Wash Module for LC/MS Tool Passive Wash Module for use with LC/MS Tools or Dilutor Tools Requires FW 2.0.x or higher |
| PAL System Large Wash Module - PAL3-WashLarge | |
![]() | Wash Module for large volume injections consisting of: 2 pcs 100 ml Solvent container (glass) with septum cap |
| PAL System Solvent Module - PAL3-SolventModule | |
![]() | PAL Solvent Module with 3 pcs 100 ml Solvent Bottles (glass) with septum cap. For large solvent demands, e.g. for the addition of larger volumes of solvents or serial dilutions |
| PAL System Tray Holder for Racks or Plates - PAL3-Trayholder | |
![]() | PAL System Tray Holder for the storage of: 3 pcs Standard microtiter plates |
| PAL System Tray Cooler - PAL3-TrayCooler | |
![]() | PAL System Tray Cooler for the storage of 3 pcs Standard microtiter plates • Under defined temperature conditions between 4 °C and 40 °C Requires firmware version 3.1.21 or higher |
| PAL System Tray Holder and Sample Tray - PAL3-LiqCooler | |
![]() | Tray Holder and Sample Tray • Temperature range between 4°C- 70°C |
| PAL Stack for 6DW and 12MT | |
![]() | For the storage of racks or plates at room temperature allows to store samples with light sensitive compounds |
| PAL Peltier Stack for 2DW, 6DW and 12MT | |
![]() | For the storage of racks or plates under defined temperature conditions temperature range between 4 °C and 40 °C |
| PAL System Valve Drive for Valco valves - PAL3-ValveDrive-V | |
![]() | PAL System Valve Drive (without valve) for Valco Valves for applications like sample injection, column switching for online LC-LC/MS or online SPE-LC/MS, Multiplexing, column selection and many more. Consisting of: 1 pc Valve Drive • Injection port bottom sensing minimizes carryover Requires firmware version 1.4.0 or higher |