Waters™ ACQUITY Premier Peptide BEH C18, 300Å, 1.7 µm 2.1 x 150 mm MVK, 3/pk
Product Number: 186009647
Specifications:
Chemistry | C18 |
Separation Mode | Reversed Phase |
Particle Substrate | Hybrid |
pH Range Min | 1 pH |
pH Range Max | 12 pH |
Maximum Pressure | 18000 psi (1240 Bar) |
Endcapped | Yes |
Silanol Activity | Low |
Particle Shape | Spherical |
Particle Size | 1.7 µm |
Endfitting Type | Parker-style |
Pore Size | 130 Å |
QC Tested | Peptide |
Format | Method Validation Kit |
Surface Area | 185 |
System | UPLC |
Particle Technology | BEH |
Technique | LC |
USP Classification | L1 |
Inner Diameter | 2.1 mm |
Length | 150 mm |
Carbon Load | 18 % |
eCord | Yes |
UNSPSC | 41115709 |
Brand | ACQUITY |
Product Type | Column Kits |
Units per Package | 3 pk |
The ACQUITY Premier BEH130 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis. This column is part of the Premier class of columns, which deliver the chromatographic performance expected from our particle technologies while increasing reproducibility, peak shape, and recovery for metal-sensitive analytes. The method validation kit (MVK) contains three columns each packed with a different lot of material.
BEH Method Validation Kits
The method validation kit (MVK) contains three columns each packed with a different lot of material. As the premier column for method development, ACQUITY Premier BEH C18 columns provides you with the most universal column choice for high performance separations. MaxPeak High Performance Surface hardware technology significantly reduces unwanted analyte/surface interactions that can lead to poor peak shape and losses in signal intensity. The trifunctionally bonded BEH particle gives you the widest usable pH range (pH 1-12), which is ideal for methods development. The VanGuard Fit column design protects the column from contaminants and increases column lifetime.
ACQUITY Premier Columns
Stop looking and start seeing – no compromise required
Reduce the risks associated with unpredictable chromatography with ACQUITY Premier Columns with MaxPeak High Performance Surfaces (HPS) Technology, which allow you to see and do more by reducing analyte/surface interactions.
With Waters ACQUITY Premier Columns, chromatographers can harness the separation efficiency improvements and increased flow rates of ultra-performance liquid chromatography (UPLC) technology, improving analyte resolution, sensitivity, business productivity, and profitability. As the next evolution in the ACQUITY UPLC Column family, ACQUITY Premier Columns are built on the industry-leading sub-2-µm particle technologies from Waters you trust.
- Reduces column conditioning and passivation for higher productivity
- Increases reproducibility from analysis to analysis, for more confidence in analytical results
- Reduces non-specific absorption for increased sensitivity, improved peak shape, and easier analyte integration
- Provides superior separation speed, sensitivity, and resolution with best-in-class column efficiency
- 3 UPLC particles of various substrate technologies, including Ethylene Bridged Hybrid (BEH), High Strength Silica (HSS), and Charged Surface Hybrid (CSH)
- Reversed-phase and HILIC stationary phases, including C18, Embedded-Polar, and Amide
- Application-specific column chemistries for peptides, proteins, oligonucleotides, and glycan analysis
- Prolonged column lifetimes with VanGuard FIT Columns, and easy-to-use, all-in-one guard/column design
Recommended Use: For increased sensitivity, improved peak shape, and less column equilibration time in methods development.
ACQUITY Premier Peptide BEH C18 Columns
- Suited for the reversed-phase analysis of hydrophobic and hydrophilic peptides at low and high pH
- Outstanding peak capacity and peak shape in TFA or FA when compared to 100% silica based C18 columns
- Two pore sizes (130Å and 300Å) for a wide range of peptides
- Superior peak shape and reduced tailing for acidic peptides
- Enhanced recovery and sensitivity for acidic peptides
BEH (Ethylene Bridged Hybrid) Technology
In 1999, Waters launched the XTerra family of HPLC columns featuring first generation hybrid particle technology (HPT). HPT enabled XTerra columns to become one of the most successful column products in the history of Waters. In HPT, the best properties of inorganic (silica) and organic (polymeric) packings are combined to produce a material that has superior mechanical strength, efficiency, high pH stability and peak shape for bases. The first generation methyl hybrid particles of XTerra columns did not possess the mechanical strength or efficiency necessary to fully realize the potential speed, sensitivity and resolution capabilities of UPLC technology. Therefore, a new pressure-tolerant particle needed to be created. A new, second generation hybrid material was developed which utilizes an ethylene bridged hybrid (BEH) structure. Compared to the first generation methyl hybrid particle of XTerra columns, the BEH particle of ACQUITY UPLC BEH columns exhibits improved efficiency, strength and pH range. BEH Technology™ is a key enabler behind the speed, sensitivity and resolution of UPLC separations.
ACQUITY UPLC columns
ACQUITY UPLC columns are the most technologically advanced LC columns ever created and are the only columns designed, tested and certified to withstand the pressures of UPLC Technology. Based upon the highly efficient 1.7 µm Bridged Ethyl Hybrid (BEH) particles and 1.8 µm High Strength Silica (HSS) particles, these columns are the first and only columns that allow separation scientists to achieve maximum speed, sensitivity and resolution without compromise. The particles and chemistries of the ACQUITY UPLC column family were carefully chosen to produce the ideal combination of ultra-performance efficiencies, wide pH range and complementary selectivities. ACQUITY UPLC BEH columns and ACQUITY UPLC HSS columns are the only columns recommended for use with ACQUITY UPLC Systems.
There is more to creating a UPLC particle than synthesizing a small particle. Many HPLC particles do not possess the mechanical stability and structural integrity to withstand UPLC operating pressures (e.g., 15000 psi/1000 bar). Why is pressure tolerance important? In order to realize the efficiency gains of sub-2 μm particles, the ability to routinely operate at higher linear velocities (e.g., higher flow rates) is required. These higher linear velocities combined with small, sub-2 μm particles result in higher operating backpressures. Waters has created two highly efficient, pressure-tolerant UPLC particles: the 1.7 μm Ethylene Bridged Hybrid (BEH) particle and the 1.8 μm High Strength Silica (HSS) particle.
The first ACQUITY UPLC particle created was the 1.7 μm Ethylene Bridged Hybrid (BEH) particle. This second generation hybrid particle is one of the key enablers behind UPLC technology and is available in five column chemistries: C18, C8, Shield RP18, Phenyl and HILIC. Because this is a hybrid particle, a wider usable pH range (up to pH 1-12) makes method development faster and easier. BEH particles are also available in HPLC particle sizes (2.5, 3.5, 5 and 10 μm) in the XBridge family of HPLC columns, thus allowing seamless transfer between HPLC and UPLC separations.
Related Products:
- 186006371 - Cytochrome C Digestion Standard
- 186009126 - mAb Tryptic Digestion Standard
- Model: 186009647
- Manufactured by: Waters