Welcome, Sign In First time visitor? Create a New Account
Your cart is empty

Waters ACQUITY UPLC Protein BEH C4 Column, 300A, 1.7 um, 1 mm x 100 mm, 1/pk - 186005590

Price: £868.00


Qty. 
+-
Download Data Sheet

Waters™ ACQUITY UPLC Protein BEH C4 Column, 300 Å, 1.7 µm, 1 mm x 100 mm, 1/pk

Product Number: 186005590

Specifications:

Chemistry C4
Separation Mode Reversed Phase
Particle Substrate Hybrid
pH Range Min 2 pH
pH Range Max 10 pH
Endcapped No
Silanol Activity Low
Molecular Weight Range Max 150000
Particle Shape Spherical
Particle Size 1.7 µm
Endfitting Type Parker-style
Pore Size 300 Å
QC Tested Protein
Format Column
System UHPLC, UPLC
Particle Technology BEH
USP Classification L26
Inner Diameter 1 mm
Length 100 mm
Carbon Load 8%
UNSPSC 41115709
Application Protein
Brand ACQUITY UPLC
Product Type Columns
Units per Package 1 pk

The ACQUITY UPLC Protein BEH C4, 300 Å, 1.7 µm, 1 mm x 100 mm column is QC tested and optimized to separate proteins based on size, hydrophobicity and isoelectric point. If you compare to traditional C18 phases, the C4 ligand is less retentive and will minimize protein carryover, increase protein recovery, and improve peak capacity.

Peptide Separation Technology

The ACQUITY BEH130 C18 Peptide Separation Technology (PST) columns have been specially optimized and QC tested for peptide separations. The small-pore (130Å) trifunctionally bonded BEH particle offers the widest usable pH range, superior low pH stability, and ultra-low column bleed to assay samples for proteomics, protein characterization, and peptide synthesis.

  • Improved chromatography of peptides with narrow, symmetrical peaks for best resolution n Suitable for a wide range of peptides,
  • including large, small, acidic, basic, hydrophobic and hydrophilic
  • Good peak shape and retention in formic acid and TFA for optimal chromatography and detection
  • Available in 130Å and 300Å pore sizes www.waters.com/PST

ACQUITY UPLC Peptide Columns

ACQUITY UPLC Peptide BEH C18, 130 Å or 300 Å Columns offer a wide usable pH range and outstanding temperature stability for applications ranging from proteomics to peptide mapping. ACQUITY UPLC CSH C18, 130 Å Peptide Columns with a low-positive charged surface can be used with standard TFA-containing eluents or with a weaker acid modifier such as formic acid, eliminating the need to compromise between a reversed-phase eluent that delivers sharp peaks or one that minimizes reduction of the MS signal.

BEH (Ethylene Bridged Hybrid) Technology

In 1999, Waters launched the XTerra family of HPLC columns featuring first generation hybrid particle technology (HPT). HPT enabled XTerra columns to become one of the most successful column products in the history of Waters. In HPT, the best properties of inorganic (silica) and organic (polymeric) packings are combined to produce a material that has superior mechanical strength, efficiency, high pH stability and peak shape for bases. The first generation methyl hybrid particles of XTerra columns did not possess the mechanical strength or efficiency necessary to fully realize the potential speed, sensitivity and resolution capabilities of UPLC technology. Therefore, a new pressure-tolerant particle needed to be created. A new, second generation hybrid material was developed which utilizes an ethylene bridged hybrid (BEH) structure. Compared to the first generation methyl hybrid particle of XTerra columns, the BEH particle of ACQUITY UPLC BEH columns exhibits improved efficiency, strength and pH range. BEH Technology™ is a key enabler behind the speed, sensitivity and resolution of UPLC separations.

ACQUITY UPLC columns

ACQUITY UPLC columns are the most technologically advanced LC columns ever created and are the only columns designed, tested and certified to withstand the pressures of UPLC Technology. Based upon the highly efficient 1.7 µm Bridged Ethyl Hybrid (BEH) particles and 1.8 µm High Strength Silica (HSS) particles, these columns are the first and only columns that allow separation scientists to achieve maximum speed, sensitivity and resolution without compromise. The particles and chemistries of the ACQUITY UPLC column family were carefully chosen to produce the ideal combination of ultra-performance efficiencies, wide pH range and complementary selectivities. ACQUITY UPLC BEH columns and ACQUITY UPLC HSS columns are the only columns recommended for use with ACQUITY UPLC Systems.

There is more to creating a UPLC particle than synthesizing a small particle. Many HPLC particles do not possess the mechanical stability and structural integrity to withstand UPLC operating pressures (e.g., 15000 psi/1000 bar). Why is pressure tolerance important? In order to realize the efficiency gains of sub-2 μm particles, the ability to routinely operate at higher linear velocities (e.g., higher flow rates) is required. These higher linear velocities combined with small, sub-2 μm particles result in higher operating backpressures. Waters has created two highly efficient, pressure-tolerant UPLC particles: the 1.7 μm Ethylene Bridged Hybrid (BEH) particle and the 1.8 μm High Strength Silica (HSS) particle.

The first ACQUITY UPLC particle created was the 1.7 μm Ethylene Bridged Hybrid (BEH) particle. This second generation hybrid particle is one of the key enablers behind UPLC technology and is available in five column chemistries: C18, C8, Shield RP18, Phenyl and HILIC. Because this is a hybrid particle, a wider usable pH range (up to pH 1-12) makes method development faster and easier. BEH particles are also available in HPLC particle sizes (2.5, 3.5, 5 and 10 μm) in the XBridge family of HPLC columns, thus allowing seamless transfer between HPLC and UPLC separations.

 


  • Model: 186005590
  • Manufactured by: Waters