Part Number: EXL-1010-7503U
Title: Avantor® ACE® Excel® C18-PFP Analytical HPLC Column, 2 µm, 100 Å, 3 x 75 mm, 1pk - EXL-1010-7503U
Avantor® ACE® Excel® C18-PFP phase utilizes a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 to 5 µm) and complementary phases
- Also useful for analytes with π-bonding or electron or proton donor groups
- Ultra-low bleed to ensure LC-MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
Due to its integral pentafluoro phenyl functionality, Avantor® ACE® C18-PFP is also recommended for separations that involve halogenated aromatic compounds, Regio isomers, and those analytes with differing shape constraints.
These columns are made from stainless steel.
Title: Avantor® ACE® Excel® C18-PFP Analytical HPLC Column, 2 µm, 100 Å, 3 x 75 mm, 1pk - EXL-1010-7503U
Avantor® ACE® Excel® C18-PFP phase utilizes a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 to 5 µm) and complementary phases
- Also useful for analytes with π-bonding or electron or proton donor groups
- Ultra-low bleed to ensure LC-MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
Due to its integral pentafluoro phenyl functionality, Avantor® ACE® C18-PFP is also recommended for separations that involve halogenated aromatic compounds, Regio isomers, and those analytes with differing shape constraints.
These columns are made from stainless steel.
Specifications:
| Column format | Analytical |
| Phase | C18-PFP |
| Pore size | 100 Å |
| Particle size | 2 µm |
| Ø int. | 3.00 mm |
| Length | 75 mm |
| Connection | 1/16" connection |
| Pk | 1 |
| P/N | EXL-1010-7503U |
| Carbon load | 14.3% |
| Endcapped | Yes |
| Max. pressure | 1000 bar |
| pH range | 2 - 8 |
| Surface area | 300 m²/g |
| USP code | L1 |
Guard cartridges, ACE guard holder may be required
| Description | Column format | Phase | Particle size | Pk | P/N |
|---|---|---|---|---|---|
| For analytical UHPLC columns (2.1 - 3.0 mm ID) | Guard cartridge | C18-PFP | 1.7 µm | 3 | ACE-1P10-GD2U |
| For analytical columns (4.0 - 4.6 mm ID) | Guard cartridge | C18-PFP | 2 µm | 3 | ACE-1P10-GD4U |
Guard holders and accessories
| Description | Pk | P/N |
|---|---|---|
| UHPLC guard cartridge holder for 2.1 to 4.6 mm ID columns | 1 | H0011 |
| Column coupler (for use with H0001/H0002) | 1 | C0001 |
- Model: EXL-1010-7503U
- Manufactured by: Avantor