Part Number: EXL-1110-1546U
Title: Avantor® ACE® Excel® C18-PFP Analytical HPLC Column, 3 µm, 100 Å, 4.6 x 150 mm, 1pk - EXL-1110-1546U
Avantor® ACE® Excel® C18-PFP phase utilizes a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 to 5 µm) and complementary phases
- Also useful for analytes with π-bonding or electron or proton donor groups
- Ultra-low bleed to ensure LC-MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
Due to its integral pentafluoro phenyl functionality, Avantor® ACE® C18-PFP is also recommended for separations that involve halogenated aromatic compounds, Regio isomers, and those analytes with differing shape constraints.
These columns are made from stainless steel.
Title: Avantor® ACE® Excel® C18-PFP Analytical HPLC Column, 3 µm, 100 Å, 4.6 x 150 mm, 1pk - EXL-1110-1546U
Avantor® ACE® Excel® C18-PFP phase utilizes a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 to 5 µm) and complementary phases
- Also useful for analytes with π-bonding or electron or proton donor groups
- Ultra-low bleed to ensure LC-MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
Due to its integral pentafluoro phenyl functionality, Avantor® ACE® C18-PFP is also recommended for separations that involve halogenated aromatic compounds, Regio isomers, and those analytes with differing shape constraints.
These columns are made from stainless steel.
Specifications:
Column format | Analytical |
Phase | C18-PFP |
Pore size | 100 Å |
Particle size | 3 µm |
Ø int. | 4.60 mm |
Length | 150 mm |
Connection | 1/16" connection |
Pk | 1 |
P/N | EXL-1110-1546U |
Carbon load | 14.3% |
Endcapped | Yes |
Max. pressure | 1000 bar |
pH range | 2 - 8 |
Surface area | 300 m²/g |
USP code | L1 |
Guard cartridges, ACE guard holder may be required
Description | Column format | Phase | Pore size | Particle size | Pk | P/N |
---|---|---|---|---|---|---|
For analytical columns (I-Ø 3.0, 4.0, 4.6 mm) | Guard cartridge | C18-PFP | 100 Å | 3 µm | 5 | ACE-1110-0103GD |
For microbore columns (I-Ø 2.1 mm) | Guard cartridge | C18-PFP | 100 Å | 3 µm | 5 | ACE-1110-0102GD |
Guard holders and accessories
Description | Pk | P/N |
---|---|---|
1 cm stand-alone cartridge holder for 1.0 to 4.6 mm ID columns | 1 | H0001 |
Column coupler (for use with H0001/H0002) | 1 | C0001 |
- Model: EXL-1110-1546U
- Manufactured by: Avantor