Part Number: ACE-139-2546
Title: Avantor® ACE® C18-AR Analytical HPLC Column, 10 µm, 100 Å, 4.6 x 250 mm, 1pk - ACE-139-2546
The Avantor® ACE® C18-AR phase utilises a specially developed ligand combining a C18 chain with integral phenyl functionality, thus combining the benefits of both C18 and phenyl characteristics into a single phase. This can be used for ‘standard’ C18 column separations, but is additionally recommended for separations that involve compounds containing aromatic functionality.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (2 to 10 µm) and complementary phases
- Ultra low bleed to ensure LC/MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
These columns are made from stainless steel.
Title: Avantor® ACE® C18-AR Analytical HPLC Column, 10 µm, 100 Å, 4.6 x 250 mm, 1pk - ACE-139-2546
The Avantor® ACE® C18-AR phase utilises a specially developed ligand combining a C18 chain with integral phenyl functionality, thus combining the benefits of both C18 and phenyl characteristics into a single phase. This can be used for ‘standard’ C18 column separations, but is additionally recommended for separations that involve compounds containing aromatic functionality.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (2 to 10 µm) and complementary phases
- Ultra low bleed to ensure LC/MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
These columns are made from stainless steel.
Specifications:
Column format | Analytical |
Phase | C18-AR |
Pore size | 100 Å |
Particle size | 10 µm |
Ø int. | 4.60 mm |
Length | 250 mm |
Pk | 1 |
P/N | ACE-139-2546 |
Carbon load | 15.5% |
Max. pressure | 275 bar |
USP code | L1 |
Guard cartridges, ACE HPLC guard holder may be required
Description | Column format | Phase | Pore size | Particle size | Pk | P/N |
---|---|---|---|---|---|---|
For semi-preparative columns (I-Ø 7,75, 10.0 mm) | Guard cartridge | C18-AR | 100 Å | 10 µm | 3 | ACE-139-0110GD |
Guard holders and accessories
Description | Pk | P/N |
---|---|---|
1 cm stand-alone cartridge holder for 1.0 to 4.6 mm ID columns | 1 | H0001 |
Semi-preparative cartridge holder for 7,75 to 21.2 mm ID columns | 1 | H0002 |
Preparative guard cartridge holder for 30 mm ID columns | 1 | H0009 |
Column coupler (for use with H0001/H0002) | 1 | C0001 |
Column coupler (for use with H0009) | 1 | C0002 |
- Model: ACE-139-2546
- Manufactured by: Avantor