Part Number: ACE-129-2504
Title: Avantor® ACE® C18-AR Analytical HPLC Column, 5 µm, 100 Å, 4 x 250 mm, 1pk - ACE-129-2504
The Avantor® ACE® C18-AR phase utilises a specially developed ligand combining a C18 chain with integral phenyl functionality, thus combining the benefits of both C18 and phenyl characteristics into a single phase. This can be used for ‘standard’ C18 column separations, but is additionally recommended for separations that involve compounds containing aromatic functionality.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (2 to 10 µm) and complementary phases
- Ultra low bleed to ensure LC/MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
These columns are made from stainless steel.
Title: Avantor® ACE® C18-AR Analytical HPLC Column, 5 µm, 100 Å, 4 x 250 mm, 1pk - ACE-129-2504
The Avantor® ACE® C18-AR phase utilises a specially developed ligand combining a C18 chain with integral phenyl functionality, thus combining the benefits of both C18 and phenyl characteristics into a single phase. This can be used for ‘standard’ C18 column separations, but is additionally recommended for separations that involve compounds containing aromatic functionality.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (2 to 10 µm) and complementary phases
- Ultra low bleed to ensure LC/MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
These columns are made from stainless steel.
Specifications:
Column format | Analytical |
Phase | C18-AR |
Pore size | 100 Å |
Particle size | 5 µm |
Ø int. | 4.00 mm |
Length | 250 mm |
Connection | 1/16" connection |
Pk | 1 |
P/N | ACE-129-2504 |
Carbon load | 15.5% |
Endcapped | Yes |
Max. pressure | 275 bar |
pH range | 2 - 8 |
Surface area | 300 m²/g |
USP code | L1 |
Guard cartridges, ACE HPLC guard holder may be required
Description | Column format | Phase | Pore size | Particle size | Pk | P/N |
---|---|---|---|---|---|---|
For semi-preparative columns (I-Ø 7,75, 10.0 mm) | Guard cartridge | C18-AR | 100 Å | 5 µm | 3 | ACE-129-0110GD |
For analytical columns (I-Ø 4.6, 3.0, 4.0 mm) | Guard cartridge | C18-AR | 100 Å | 5 µm | 5 | ACE-129-0103GD |
For preparative coulmns (I-Ø 30.0 mm) | Guard cartridge | C18-AR | 100 Å | 5 µm | 3 | ACE-129-0120GD |
For analytical columns (I-Ø 2.1 mm) | Guard cartridge | C18-AR | 100 Å | 5 µm | 5 | ACE-129-0102GD |
Guard holders and accessories
Description | Pk | P/N |
---|---|---|
Semi-preparative cartridge holder for 7,75 to 21.2 mm ID columns | 1 | H0002 |
1 cm stand-alone cartridge holder for 1.0 to 4.6 mm ID columns | 1 | H0001 |
Preparative guard cartridge holder for 30 mm ID columns | 1 | H0009 |
Column coupler (for use with H0001/H0002) | 1 | C0001 |
Column coupler (for use with H0009) | 1 | C0002 |
Method validation kits
Column format | Phase | Pore size | Particle size | Ø int. | Length | Connection | Pk | P/N |
---|---|---|---|---|---|---|---|---|
Method Validation Kit | C18-AR | 100 Å | 5 µm | 4.60 mm | 250 mm | 1/16" connection | 1 KIT | ACE1292546MVK |
- Model: ACE-129-2504
- Manufactured by: Avantor