Part Number: ACE-132-1546
Title: Avantor® ACE® C8 Analytical HPLC Column, 10 µm, 100 Å, 4.6 x 150 mm, 1pk - ACE-132-1546
These ultra-inert Avantor® ACE® C8 columns provide great reproducibility and column lifetime. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (2 µm to 10 µm) and complementary phases
- Can be used as general purpose starting point column
- Method validation kits contain three different batches of the same phase - available on request
These columns are designed for a wide range of chromatographic applications, to provide great performance with acidic, basic and neutral molecules.
Title: Avantor® ACE® C8 Analytical HPLC Column, 10 µm, 100 Å, 4.6 x 150 mm, 1pk - ACE-132-1546
These ultra-inert Avantor® ACE® C8 columns provide great reproducibility and column lifetime. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (2 µm to 10 µm) and complementary phases
- Can be used as general purpose starting point column
- Method validation kits contain three different batches of the same phase - available on request
These columns are designed for a wide range of chromatographic applications, to provide great performance with acidic, basic and neutral molecules.
Specifications:
| Column format | Analytical | 
| Phase | C8 | 
| Pore size | 100 Å | 
| Particle size | 10 µm | 
| Ø int. | 4.60 mm | 
| Length | 150 mm | 
| Pk | 1 | 
| P/N | ACE-132-1546 | 
| Carbon load | 9% | 
| Endcapped | Yes | 
| Max. pressure | 275 bar | 
| pH range | 2 - 8 | 
| Surface area | 300 m²/g | 
| USP code | L7 | 
Guard cartridges, ACE HPLC guard holder may be required
| Description | Column format | Phase | Pore size | Particle size | Pk | P/N | 
|---|---|---|---|---|---|---|
| For semi-preparative columns (I-Ø 7,75, 10.0 mm) | Guard cartridge | C8 | 100 Å | 10 µm | 3 | ACE-132-0110GD | 
Guard holders and accessories
| Description | Pk | P/N | 
|---|---|---|
| 1 cm stand-alone cartridge holder for 1.0 to 4.6 mm ID columns | 1 | H0001 | 
| Semi-preparative cartridge holder for 7,75 to 21.2 mm ID columns | 1 | H0002 | 
| Column coupler (for use with H0001/H0002) | 1 | C0001 | 
- Model: ACE-132-1546
- Manufactured by: Avantor

 
					
											 
	
     
    


















