Part Number: ACE-213-10005
Title: Avantor® ACE® C4 Microbore HPLC Column, 3 µm, 300 Å, 0.5 x 100 mm, 1pk - ACE-213-10005
Avantor® ACE® C4-300 columns provide great reproducibility and column lifetime. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (3. 5 and 10 µm) and complementary phases
- Designed for peptide and protein separations
- Method validation kits contain three different batches of the same phase - available on request
These columns are designed for a wide range of chromatographic applications, to provide great performance with acidic, basic and neutral molecules.
Title: Avantor® ACE® C4 Microbore HPLC Column, 3 µm, 300 Å, 0.5 x 100 mm, 1pk - ACE-213-10005
Avantor® ACE® C4-300 columns provide great reproducibility and column lifetime. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (3. 5 and 10 µm) and complementary phases
- Designed for peptide and protein separations
- Method validation kits contain three different batches of the same phase - available on request
These columns are designed for a wide range of chromatographic applications, to provide great performance with acidic, basic and neutral molecules.
Specifications:
| Column format | Microbore | 
| Phase | C4 | 
| Pore size | 300 Å | 
| Particle size | 3 µm | 
| Ø int. | 0.50 mm | 
| Length | 100 mm | 
| Connection | 1/16" connection | 
| Pk | 1 | 
| P/N | ACE-213-10005 | 
| Carbon load | 2.6% | 
| Endcapped | Yes | 
| Max. pressure | 275 bar | 
| pH range | 2 - 8 | 
| Surface area | 100 m²/g | 
| USP code | L26 | 
Guard cartridges - Stand-alone guard cartridge holder and column coupler may be required
| Description | Column format | Phase | Pore size | Particle size | Pk | P/N | 
|---|---|---|---|---|---|---|
| For analytical columns (I-Ø 2.1 mm) | Guard cartridge | C4 | 300 Å | 3 µm | 5 | ACE-213-0102GD | 
| For analytical columns (I-Ø 3.0, 4.0, 4.6 mm) | Guard cartridge | C4 | 300 Å | 3 µm | 5 | ACE-213-0103GD | 
Guard holders and accessories
| Description | Pk | P/N | 
|---|---|---|
| Column coupler (for use with H0001/H0002) | 1 | C0001 | 
| 1 cm stand-alone cartridge holder for 1.0 to 4.6 mm ID columns | 1 | H0001 | 
Method validation kit
| Description | Column format | Phase | Pore size | Particle size | Pk | P/N | 
|---|---|---|---|---|---|---|
| For analytical columns (I-Ø 4.6 mm) | Method Validation Kit | C4 | 300 Å | 3 µm | 1 KIT | ACE2131046MVK | 
| For analytical columns (I-Ø 4.6 mm) | Method Validation Kit | C4 | 300 Å | 3 µm | 1 KIT | ACE2131546MVK | 
- Model: ACE-213-10005
 - Manufactured by: Avantor
 

					
											