THIS PRODUCT HAS BEEN DISCONTINUED - PLEASE CONTACT US FOR FURTHER INFORMATION.
Biotech High-Flow Degasser, 1000 mL/min
Product Number: 0001-6706
SYSTEC’s High Flow Degasser module includes a high efficiency, non-porous membrane and controlled vacuum pump for liquid vacuum degassing applications.
Features
- Removes dissolved gasses and bubbles from fluidic lines to improve dispense precision
- Longest lifetime pump and membrane materials are selected to reduce maintenance and provide best TCO
- Compatible with broad range of fluids including aqueous salts, organics, detergents and sterilizing agents (pH range: 2 to 13)
- Highest efficiency membrane reduces unit size to increase lab space
- Tested and calibrated assembly is ready for installation
TECHNICAL SPECIFICATIONS
- Operational flow rate (mL/min): 0 - 1,000
- Pressure Drop (@ 20 °C & Max Flow): < 15 kPa
- Internal Volume: < < 45 mL
- Degassing Efficiency (Removed O2% in DI Water @ Max Flow): > 50%
- Number of Channels: 1
- Wetted Materials: Polysulfone, silicone rubber, polypropylene, Tygon S-50-HL, medical grade adhesives
- External Fluidic Ports: 3/16 inch (4.8 mm) ID Barb Fittings
- Maximum Operating Pressure: < 2 Barg
- Maximum Temperature: 40 °C
PUMP CONTROL SPECIFICATIONS
- Power Requirements: 24 VDC @ 0.75 Amp max. (<5 Watt typical)
- Vacuum Sensor Calibration Accuracy: (NIST Traceable) ±5 mmHg absolute over an ambient operating temperature range of 10-35°C.
- Closed-Loop Control Setpoint: 120 mmHg (16kPa) absolute (pump runs at high RPM until near setpoint, then speed is varied to maintain a value of 120 mmHg (16kPa) absolute – load independent).
- LED Indicators
- Single Bi-Color
- Power on, vacuum above control range: Amber– Blinking
- Vacuum reaches upper control range: Green-Blinking
- Vacuum reaches control set point: Green—Solid
- Error Condition, Shutdown: Amber—Solid
Errors Detected
- Pumpdown: Unable to reach 120 mmHg (16kPa) in 10 minutes.
- High Vacuum: Vacuum > 200 mmHg (26.7kPa) for > 10 min.
- Sensor Signal: Sensor >800 mmHg (106.7kPa) or <10 mmHg (1.3kPa).
VACUUM PUMP TECHNICAL DATA
- Air Flow (no vacuum): 580 SCCM @ 250 RPM; 140 SCCM @ 60 RPM
- Vacuum Performance Specification: <150 mmHg (20kPa) @ 120 RPM & 1 SCCM air flow (Test Criteria)
- Pump Head Continuous Purge Air Flow Rate: 11 SCCM
- Materials in Fluid Path: Stainless Steel, Polypropylene, PTFE, EPDM Rubber, PPS
- Expected Lifetime: >6 years (continuous run @ 100 RPM 12 hours/day 365 days/year)
International Power Adapter Included
- AC adapter: 100-240V AC, 1A, 50-60Hz
- includes adapters for North America, Japan, UK, Continental Europe, Australia
- Model: 0001-6706
- Manufactured by: Biotech