Welcome, Sign In First time visitor? Create a New Account
Your cart is empty

CERI L-column2 C8 Micro Column, PEEK-sleeved, 120 A, 3 um, 0.2 mm I.D. x 50 mm Length, 1/pk - 711291

Price: £785.23


Qty. 
+-
Download Data Sheet

L-column2 C8

CERI L-column2 C8 Micro Column, PEEK-sleeved, 120Å, 3µm, 0.2mm I.D. x 50mm Length, 1/pk

Product Number: 711291

Specifications:

Package specification C8 (RP8, Octyl)
Endcapping yes
mode Reversed Phase (RP)
Particle Size 3 µm
pH Range 2 - 7.5
Pore size 120 Å
USP number L7
Inner diameter 0.2 mm
Length 50 mm

 

Micro column

Micro column is a nano/micro column with 0.075 mm- 0.3 mm I.D. It is a high-performance column that was manufactured by combining low-absorption packing materials, including L-column series, an originally developed packing technique and a column structure with a small dead volume.

This column is easy to handle because it is a fused silica capillary with an outer sleeve of PEEK resin. Connection to MS is easy because connectors are attached to the column.

  • Inner diameter: 0.075 mm-0.3 mm
  • Connection: 1/16 inch stainless-steel connector

L-column2 C8 is end-capped using the same advanced method used for L-column2 ODS. This column is easy to use because it provides sharp peaks in addition to it having high durability. L-column2 C8 is most suitable for reducing the analysis time of hydrophobic compounds and conserving solvent.

L-column series is the column for reversed-phase high-performance liquid chromatography (RP-HPLC) that enabled separation only by hydrophobic interaction because of inhibition of the secondary interaction with residual silanol groups and metal impurities.

L-column2, surpassing L-column in performance was developed by upgrading the end-capping method. There is now a demand for RP-HPLC columns capable of both handling various issues of trace analysis due to the popularity of LC/MS or MS and providing advanced analytical preision. Lcolumn2 is an ideal column for meeting this demand.

The main retention mechanisms of L-column2 C6-Phenyl are π-π interaction and hydrophobicity. L-column2 C6-Phenyl can use the same eluent as an C18, and can obtain some different separation patterns.

Advantages:

  • Sharper peaks for acidic, basic and coordination compounds due to extremely low silanol adsorption.
  • High durability in a wide range of pH and temperature.
  • Superior peak shapes in both acetonitrile/water and methanol/water eluents makes Lcolumn2 convenient to use.
  • Uniform lot to lot reproducibility of analyses due to extensive quality control measures.

USP

L7: Octyl silane chemically bonded to totally or superficially porous silica particles, 1.5 to 10 μm in diameter, or a monolithic silica rod.

Additional CERI Products:

 


  • Model: 711291
  • Manufactured by: CERI