Welcome, Sign In First time visitor? Create a New Account
Your cart is empty

CERI L-column2 ODS Analytical HPLC Column, 120 A, 3 um, 1.0 mm I.D. x 100 mm Length, 1/pk - 711610

Price: £464.00


Qty. 
+-
Download Data Sheet

L-column2 ODS

CERI L-column2 ODS Analytical HPLC Column, 120Å, 3µm, 1.0mm I.D. x 100mm Length, 1/pk

Product Number: 711610

Specifications:

Package specification C18 (RP18, ODS, Octadecyl)
Endcapping yes
mode Reversed Phase (RP)
Particle Size 3 µm
pH Range 2 - 9
Pore size 120 Å
USP number L1
Inner diameter 1 mm
Length 100 mm

 

L-column2 ODS exceeds even the high performance of L-column ODS by virtue of its advanced new end-capping method. It accommodates the analysis of acidic, basic and chelating compounds.

  • Sharper peaks for acidic, basic and chelating compounds due to extremely low silanol adsorption.
  • Superior peak shapes in both acetonitrile/water and methanol/water mobile phases makes L-column2 ODS convenient to use.
  • Economical due to high durability in a wide range of pH and temperature.
  • Uniform lot to lot reproducibility of analyses due to extensive quality control measures.

L-column series is the column for reversed-phase high-performance liquid chromatography (RP-HPLC) that enabled separation only by hydrophobic interaction because of inhibition of the secondary interaction with residual silanol groups and metal impurities.

L-column2, surpassing L-column in performance was developed by upgrading the end-capping method. There is now a demand for RP-HPLC columns capable of both handling various issues of trace analysis due to the popularity of LC/MS or MS and providing advanced analytical preision. Lcolumn2 is an ideal column for meeting this demand.

The main retention mechanisms of L-column2 C6-Phenyl are π-π interaction and hydrophobicity. L-column2 C6-Phenyl can use the same eluent as an C18, and can obtain some different separation patterns.

Advantages:

  • Sharper peaks for acidic, basic and coordination compounds due to extremely low silanol adsorption.
  • High durability in a wide range of pH and temperature.
  • Superior peak shapes in both acetonitrile/water and methanol/water eluents makes Lcolumn2 convenient to use.
  • Uniform lot to lot reproducibility of analyses due to extensive quality control measures.

USP

L1: Octadecyl silane chemically bonded to porous or non-porous silica or ceramic micro-particles, 1.5 to 10 μm in diameter, or a monolithic rod

Additional CERI Products:

 


  • Model: 711610
  • Manufactured by: CERI