L-column2 ODS
CERI L-column2 ODS Analytical HPLC Column, 120Å, 3µm, 3.0mm I.D. x 150mm Length, 1/pk
Product Number: 721260
Specifications:
Package specification | C18 (RP18, ODS, Octadecyl) |
---|---|
Endcapping | yes |
mode | Reversed Phase (RP) |
Particle Size | 3 µm |
pH Range | 2 - 9 |
Pore size | 120 Å |
USP number | L1 |
Inner diameter | 3.0 mm |
Length | 150 mm |
L-column2 ODS exceeds even the high performance of L-column ODS by virtue of its advanced new end-capping method. It accommodates the analysis of acidic, basic and chelating compounds.
- Sharper peaks for acidic, basic and chelating compounds due to extremely low silanol adsorption.
- Superior peak shapes in both acetonitrile/water and methanol/water mobile phases makes L-column2 ODS convenient to use.
- Economical due to high durability in a wide range of pH and temperature.
- Uniform lot to lot reproducibility of analyses due to extensive quality control measures.
L-column series is the column for reversed-phase high-performance liquid chromatography (RP-HPLC) that enabled separation only by hydrophobic interaction because of inhibition of the secondary interaction with residual silanol groups and metal impurities.
L-column2, surpassing L-column in performance was developed by upgrading the end-capping method. There is now a demand for RP-HPLC columns capable of both handling various issues of trace analysis due to the popularity of LC/MS or MS and providing advanced analytical preision. Lcolumn2 is an ideal column for meeting this demand.
The main retention mechanisms of L-column2 C6-Phenyl are π-π interaction and hydrophobicity. L-column2 C6-Phenyl can use the same eluent as an C18, and can obtain some different separation patterns.
Advantages:
- Sharper peaks for acidic, basic and coordination compounds due to extremely low silanol adsorption.
- High durability in a wide range of pH and temperature.
- Superior peak shapes in both acetonitrile/water and methanol/water eluents makes Lcolumn2 convenient to use.
- Uniform lot to lot reproducibility of analyses due to extensive quality control measures.
USP
L1: Octadecyl silane chemically bonded to porous or non-porous silica or ceramic micro-particles, 1.5 to 10 μm in diameter, or a monolithic rod
Additional CERI Products:
- L-Column2 ODS HPLC Columns
- L-Column2 ODS Micro Columns
- LColumn2 ODS Metal-free Columns
- CERI L-Column HPLC Columns
- CERI L-column2 HPLC Columns
- CERI L-column3 HPLC Columns
- Model: 721260
- Manufactured by: CERI