L-column3 C18
CERI L-column3 C18 Octadecyl Guard Cartridge Column, 5 μm, 10 mm Length x 4.6 mm ID, pack of 3
Product Number: 852050
C18 Octadecylsilanised silica gel for liquid chromatography
Specifications:
L-column3 C18 HPLC Columns | L-column3 C8 HPLC Columns | |
Base materials: | PCS silica (Perfect chemical stable silica) | |
Pore size: | 12 nm (120 Å) | |
Specific surface area: | 340 m2/g | |
Particle size: | 2 μm, 3 μm, 5 μm | 3 μm, 5 μm |
Bonded phase: | Octadecyl silyl (C18, ODS) | Octyl silyl (C8, Octyl) |
End-capping: | Perfect stable end-capping | |
USP category: | L1 | L7 |
Usable pH range: | pH 1 - pH 12 |
L-column3 Guard Columns and Holders
Bulking agent’s kind | Particle size | I.D. | length | Specification | Cat. No. |
L-column3 C18 | 5 μm | 2.0 mm | 5 mm | Cartridge, 3pcs | 852330 |
4.6 mm | 10 mm | Cartridge, 3pcs | 852050 | ||
10.0 mm | 20 mm | Packed, 1pc | 852110 | ||
L-column3 C8 | 5 μm | 2.0 mm | 5 mm | Cartridge, 3pcs | 852331 |
4.6 mm | 10 mm | Cartridge, 3pcs | 852331 | ||
Holders |
I.D. | length | Specification | Cat. No. | |
2.0 mm | 5 mm | Direct type, 1pc | 651332 | ||
2.0 mm | 5 mm | Non-direct type, 1pc | 652332 | ||
4.6 mm | 10 mm | Direct type, 1pc | 651052 | ||
4.6 mm | 10 mm | Non-direct type, 1pc | 652052 |
Connection type: 1/16-inch Waters (W)
* A tube and a connector, used to connect a guard column (Non-direct type, Packed type) to an analytical column, are not attached.
Silica-based columns with the many advantages of high separation efficiency and mechanical strength are currently used most generally for the columns for reversed phase chromatography. On the other hand, the pH range of usable eluent is limited because exposure to the alkaline solution are easily dissolved silica.
L-column3 is an all-around column where the chemical stability (acid and alkaline resistance) of the packing materials is dramatically improved by using newly developed and highly alkaline resistant PCS silica (perfect chemical stable silica) and perfectly stable end-capping with performance much higher than that of L-column2.
L-column3 proposes the possibility of a new analysis.
- Improving chemical stability, so that usable within the range of pH 1 to pH 12.
- Low adsorptivity is at the top level for various analytes.
- Improvement of separation or peak shape, since the pH of an eluent is flexibly selectable
- A 100% aqueous eluent can be stably analyzed.
Additional CERI Products:
- L-column3 C18 Stainless Steel Columns
- L-column3 C18 Metal-Free Columns
- L-column C18 HPLC Guard Columns and Holders
- CERI L-Column HPLC Columns
- CERI L-column2 HPLC Columns
- CERI L-column3 HPLC Columns
- Model: 852050
- Manufactured by: CERI