Manufacturers
Specials - [more]

CLEARANCE CTS Sciencix 100 µL Syringe for Thermo/Dionex WPS-3000 Series, Comparable to OEM 6822.0002 - 11-3332
£328.53 £250.31
Save: 24% off
Save: 24% off

CLEARANCE GL Sciences Inertsil ODS-3 HPLC Column, 5 µm, 50 x 4.6 mm (analytical) - 5020-01763
£325.00 £236.56
Save: 27% off
Save: 27% off

CLEARANCE Waters KIT, ASSEMBLY VALVE MANIFOLD AND PLATE for ACQUITY Sample Manager - 700010171
£1,633.00 £1,306.40
Save: 20% off
Save: 20% off

CLEARANCE Thermo Scientific Choice PES (Polyethersulfone) Syringe Filters, 0.2 μm, 13 mm, 100/Pk - CH2213-PES
£62.60 £47.70
Save: 24% off
Save: 24% off

CLEARANCE Avantor® ACE® C8 Analytical HPLC Column, 5 µm, 100 Å, 4.6 x 250 mm, 1pk - ACE-122-2546
£691.00 £552.80
Save: 20% off
Save: 20% off
New Products - [more]

Dr. Maisch DAISOGEL SP-100 ODS-P (SP-100-10-ODS-P) Preparative HPLC Column, 10 µm, 100 Å, 50 x 300 mm, 1/Pk - DA10.9P.S3050
Live chat below or contact us for latest price.
Home >
Chromatography Supplies >
Purospher HPLC Columns >
Purospher® STAR RP-18 Endcapped 150-4.6 Hibar® RT HPLC Column, 120 Å, 3 µm, 4.6 × 150 mm - 150470
Purospher® STAR RP-18 Endcapped Hibar®
Inner Diameter (I.D.): 4.6 mm
Length: 150 mm
Package Contents: 1 Column
Purospher® STAR RP-18 endcapped HPLC columns are designed for universal use. Basic, neutral, and metal chelating
compounds can easily be separated with simple mobile phases – naturally without peak tailing! Thanks to its
outstanding performance and stability, Purospher® STAR RP-18 endcapped offers maximum flexibility in method
development. Robust methods can be developed over the entire pH range from 1.5 to 10.5. The high pH-stability up
to pH 10.5 allows the separation of strongly basic compounds with alkaline eluents. The combination of high purity
silica, best all-round retention characteristics, outstanding pH stability up to pH 10.5, and suitability for up to 100%
aqueous mobile phases, make Purospher® STAR RP-18 endcapped an all-round top performance column, almost
universal in its range of applications.
The traditional heart of HPLC is the “ready-to-use” column with threads at both ends onto which reducers for capillary
connection are screwed. As a rule, precolumns are coupled with the main column via capillaries. If the column is
exhausted, the user has two possibilities: Refilling, provided aggressive eluents do not prevent this by causing corrosion
or worn threads, or the whole column is discarded. Column refilling without tube revision is problematic in view