Welcome, Sign In First time visitor? Create a New Account
Your cart is empty

Rheodyne 8125 Stainless Steel Injector Micro-Scale Dual Mode

Price: £1,862.50


Qty. 
+-



How to Choose a Sample Injector 
Table I below compares the characteristics of Rheodyne® manual sample injectors and will help you choose the most suitable model.

Types and Capabilities
Models ending in 25 (i.e. 7725) are dual mode injectors. Dual mode injectors can use both the partial-filling and the complete-filling method for loading the sample loop. They are variable volume injectors because they allow the loading of various sample volumes. These dual mode injectors, also called front-loading injectors, have a needle port for loading sample built into the handle. The unique injection port design allows the tip of the needle to connect directly to the sample loop for no sample loss during loading.

Models ending in 10 (i.e. 7010) are single mode injectors. Single mode injectors use only the complete-filling method to load the sample loop. They are called fixed loop injectors as the sample loop size determines the sample volume. These injectors require a Loop Filler Port accessory, as a needle port is not built into the valve handle. There is not a direct connection between the syringe and the sample loop. Therefore, an excess of sample must be used to overfill the Loop Filler Port and completely fill the sample loop.

Models with an "i" suffix (i.e. 7725i) are identical to the models with the same numbers but the “i” designates a built-in position sensing switch. The switch provides the chromatograph with a reproducible start signal to mark the injection time in the data system.

The reproducibility of manual sample injectors depends on operator skill, syringe calibration, and the loading method. Partial-filling method is typically reproducible to 1.0% relative standard deviation (RSD). Complete-filling method is reproducible to 0.1% RSD for loops 5 µL.

 

Scale, Sample Volume, and Loop Size
Analytical scale models are for conventional columns with samples from 1.0 µL to 5.0 mL. Microscale models are for 1.0 mm and 2.0 mm inner diameter columns. Model 8125 has a sample range of 0.1 µL to 500 µL, and can be used for both analytical and micro columns. Preparative scale models are for columns with diameters from 1 to 10 cm, and operate at high flow rates with samples from 100 µL to 20 mL.

Liquid Contact Materials
All models have a polymeric rotor seal of Vespel® (pH 0 to 10 tolerance), ETFE or PEEK™ (both pH 0 to 14). Stators are 316 stainless steel or PEEK. Most models have an inert ceramic stator face assembly.

Make-Before-Break (MBB®)
Models incorporating Rheodyne’s MBB architecture design provide uninterrupted flow when switching between LOAD and INJECT positions. MBB greatly reduces transient pressure shocks and is beneficial for flow-sensitive detectors, fragile columns, and pumps. Models 7725, 9725, 3725, and “i” versions contain the MBB design.

Replacement Parts
Genuine Rheodyne parts are available for easy maintenance of your Rheodyne valve. RheBuild® Kits offer a complete solution to keep your valve running, providing all necessary parts to rebuild your valve and easy to use step by step instructions to assist you in the process. Rheodyne also offers a complete line of sample loops, fittings, and accessories designed specifically for the Rheodyne valve.

Characteristics of Rheodyne Manual Sample Injectors

Type & Capabilities

Scale

Partial Filling
Volumes (Range)

Sample Loop Sizes (Range)

Wetted Materials

Max.
psi (bar)1

Max.
T (°C)

MBB2

Model3

Dual Mode
Can load the loop by two methods:
1) Partial filling – syringe determines volume without wasting sample

2) Complete filling – loop determines volume by over filling loop

Analytical

1 µL – 2.5 mL
1 µL – 5.0 mL

2 µL – 5.0 mL
2 µL – 10 mL

316 SST, Vespel
PEEK, ETFE, ceramic

7,000 (483)
5,000 (340)

80°
50°

Yes
Yes

7725, 7725i
9725, 9725i

Micro

0.1 µL – 500 µL

5 µL – 1.0 mL

316 SST, PEEK, Vespel, ceramic

7,000 (483)

80°

No

8125

Preparative

100 µL – 10 mL

2.0 mL – 20 mL

316 SST, PEEK
PEEK

5,000 (340)
4,000 (276)

50°
50°

Yes
Yes

3725(i)-038
3725, 3725i

Single Mode
Can load the loop by one method:
Complete filling – loop determines volume by over filling loop

Analytical

Not Applicable

5 µL – 5.0 mL
5 µL – 10 mL

316 SST, Vespel
PEEK, ETFE, Ceramic

7,000 (483)
5,000 (340)

80°
50°

No
No

7000
9010

Micro

Not Applicable

0.5 µL – 5 µL
0.2 µL – 1 µL

316 SST, Vespel
316 SST, Vespel

7,000 (483)
7,000 (483)

80°
80°

No
No

7410
7520

SST = Stainless Steel
1 This is the maximum pressure to which the valve can be adjusted. Some models are shipped from the factory set for lower pressures.

2 MBB (Make-Before-Break) is a design that provides uninterrupted flow when switching between LOAD and INJECT. MBB also greatly reduces transient pressure shocks.

3 Models with an "i" suffix have a built-in position sensing switch. Models 8125 and 9010 also have a built-in switch.



  • Model: 8125
  • Manufactured by: Rheodyne