OHpak SB-800 / OHpak LB-800 columns separation by size for a variety of molecular weights
OHpak SB-806 HQ HPLC Standard Column - 13μm - 8.0mm I.D. x 300mm Length
Shodex Product Number: F6429105
The polymer-based SEC (GFC) column for modified proteins, PEGs, polysaccharides, surfactants
Specifications
Description | OHpak SB-806 HQ 300x8mm |
---|---|
Chemistry Producers Term | SB |
Matrix | Polyhydroxymethacrylate |
Mode of Separation | Gel Filtration (GFC) / Size Exclusion (SEC) |
Pore size | 15,000 Å |
Housing material | steel |
Maximum pressure | 3.0 MPa (30 bar) |
Usual flow rate | 0.5 to 1.0 mL/min |
Maximum flow rate | 1.2 mL/min |
Temperature range | 4 to 70°C |
pH range | 3 to 10 |
Salt concentration | ≤ 0.5 M |
Shipping solvent | 0.02 % NaN3 aq. |
USP | L38, L39 |
Internal Diameter | 8 mm |
Length | 300 mm |
MW range | 100,000 - (20,000,000) |
Exclusion limit | (20,000,000) |
Brand | OHPAK |
Particle Size | 13 µm |
pH Minimum | 3.0 |
pH Maximum | 10.0 |
Pore Size | 1.5e04 |
USP Class | L38, L39 |
OHpak SB-806 HQ Features
- Polymer-based packed columns for aqueous SEC (GFC) analysis
- Supports a wide range of molecular weight sample analysis
- The eluent can be replaced with DMF (except SB-802 HQ and SB-807 HQ), enabling the analysis of polar polymers
- Method using SB-804 HQ or SB-805 HQ for gelatin's mean molecular weight determination is comparable with PAGI method (Ver. 10, Japan)
- Suitable for: Nucleic acids - DNA / RNA - SEC | Polysaccharides - SEC
- Fulfills USP L38 requirements - A methacrylate-based size-exclusion packing for water-soluble samples.
- Fulfills USP L39 requirements - A hydrophilic polyhydroxymethacrylate gel of totally porous spherical resin.
SB-800 series Possible Applications
- Aqueous SEC (GFC) - Application: Biological macromolecules (High MW range) - Eluent: Buffer etc.
- Aqueous SEC (GFC) - Application: Water-soluble polymers (Polyacrylamide, etc.) - Eluent: Water, buffer and aqueous salt solution, etc.
- Organic SEC (GPC) - Application: Polar polymers (Polyimides etc.) - Eluent: DMF
Possible Applications
- Nucleic acids - DNA / RNA - SEC
- Polysaccharides - SEC
- Poly(Vinyl Alcohol) (2) (Aqueous Eluent) (SB-806 HQ + SB-803 HQ)
- Corn Starch (2) (DMSO/DMF Eluent) (SB-806 HQ)
- Poly(Vinyl Alcohol) (2) (Aqueous Eluent) (SB-806 HQ + SB-803 HQ)Polyacrylamide (3)
- (Comparison with SB-807 HQ and SB-806 HQ)
- Polyadenylic Acid (SB-806 HQ)
- SEC Analysis of PEG-Asparaginase (SB-806 HQ)
- SEC/MALS Analysis of Exosome (SB-806 HQ)
- Polyacrylamide (3) (Comparison with SB-807 HQ and SB-806 HQ)
Range of Aqueous SEC (GFC) Columns: Polymer-based columns
Product Code | Product Name | Plate Number (TP/column) |
Particle Size (μm) |
Pore Size (Å) |
Column Size (mm) I.D. x Length |
Shipping Solvent |
Standard columns | Base Material: Polyhydroxymethacrylate | SB-806M HQ is a mixed-gel column capable of analyzing samples over a wide range of molecular weight distribution | ||||||
F6429100 | OHpak SB-802 HQ | ≥ 12,000 | 8 | 100 | 8.0 x 300 | 0.02 % NaN3 aq. |
F6429101 | OHpak SB-802.5 HQ | ≥ 16,000 | 6 | 200 | 8.0 x 300 | 0.02 % NaN3 aq. |
F6429102 | OHpak SB-803 HQ | ≥ 16,000 | 6 | 800 | 8.0 x 300 | 0.02 % NaN3 aq. |
F6429103 | OHpak SB-804 HQ | ≥ 16,000 | 10 | 2,000 | 8.0 x 300 | 0.02 % NaN3 aq. |
F6429104 | OHpak SB-805 HQ | ≥ 12,000 | 13 | 7,000 | 8.0 x 300 | 0.02 % NaN3 aq. |
F6429105 | OHpak SB-806 HQ | ≥ 12,000 | 13 | 15,000 | 8.0 x 300 | 0.02 % NaN3 aq. |
F6429106 | OHpak SB-806M HQ | ≥ 12,000 | 13 | 15,000 | 8.0 x 300 | 0.02 % NaN3 aq. |
F6709430 | OHpak SB-G 6B | (guard column) | 10 | - | 6.0 x 50 | 0.02 % NaN3 aq. |
Aqueous high molecular weight analysis column | Standard columns | Base Material: Polyhydroxymethacrylate | ||||||
F6429108 | OHpak SB-807 HQ | ≥ 1,500 | 35 | 30,000 | 8.0 x 300 | H2O |
F6709431 | OHpak SB-807G | (guard column) | 35 | 8.0 x 50 | H2O | |
Preparative columns [ Preparative columns are made to order. ] | Base Material: Polyhydroxymethacrylate | ||||||
Product Code | Product Name | Plate Number (TP/column) |
Particle Size (μm) |
Column Size (mm) I.D. x Length |
Shipping Solvent | Standard Column |
F6516011 | OHpak SB-2002 | ≥ 9,000 | 15 | 20.0 x 300 | 0.02 % NaN3 aq. | SB-802 HQ |
F6516012 | OHpak SB-2002.5 | ≥ 12,000 | 10 | 20.0 x 300 | 0.02 % NaN3 aq. | SB-802.5 HQ |
F6516013 | OHpak SB-2003 | ≥ 12,000 | 10 | 20.0 x 300 | 0.02 % NaN3 aq. | SB-803 HQ |
F6516014 | OHpak SB-2004 | ≥ 12,000 | 18 | 20.0 x 300 | 0.02 % NaN3 aq. | SB-804 HQ |
F6516015 | OHpak SB-2005 | ≥ 12,000 | 20 | 20.0 x 300 | 0.02 % NaN3 aq. | SB-805 HQ |
F6516016 | OHpak SB-2006 | ≥ 12,000 | 20 | 20.0 x 300 | 0.02 % NaN3 aq. | SB-806 HQ |
F6516017 | OHpak SB-2006M | ≥ 12,000 | 20 | 20.0 x 300 | 0.02 % NaN3 aq. | SB-806M HQ |
F6709555 | OHpak SB-G 8B | (guard column) | 18 | 8.0 x 50 | 0.02 % NaN3 aq. | (guard column) |
GFC columns to be used with light scattering detector | Standard columns | Base Material: Polyhydroxymethacrylate | ||||||
Product Code | Product Name | Plate Number (TP/column) |
Particle Size (μm) |
Pore Size (Å) |
Column Size (mm) I.D. x Length |
Shipping Solvent |
F6429206 | OHpak LB-802.5 | ≥ 16,000 | 6 | 200 | 8.0 x 300 | H2O |
F6429201 | OHpak LB-803 | ≥ 16,000 | 6 | 800 | 8.0 x 300 | H2O |
F6429204 | OHpak LB-804 | ≥ 16,000 | 10 | 2,000 | 8.0 x 300 | H2O |
F6429203 | OHpak LB-805 | ≥ 12,000 | 13 | 7,000 | 8.0 x 300 | H2O |
F6429205 | OHpak LB-806 | ≥ 12,000 | 13 | 15,000 | 8.0 x 300 | H2O |
F6429202 | OHpak LB-806M | ≥ 12,000 | 13 | 15,000 | 8.0 x 300 | H2O |
F6709434 | OHpak LB-G 6B | (guard column) | 13 | - | 6.0 x 50 | H2O |
LB-806M is a mixed-gel column capable of analyzing samples Base Material: Polyhydroxymethacrylate over a wide range of molecular weight distribution.
- Model: F6429105
- Manufactured by: Showa Denko