Welcome, Sign In First time visitor? Create a New Account
Your cart is empty

Shodex HPLC Column GPC HK-401 ID 4,6mm L 150mm - F6025010

Price: £1,992.71


Qty. 
+-
Download Data Sheet

Ultra-rapid GPC HK-400 columns with monodispers particles

GPC HK-401 HPLC Standard Column - 3μm - 4.6mm I.D. x 150mm Length

Shodex Product Number: F6108010

Organic size exclusion column for fast analysis

Specifications:

Description GPC HK-401 4,6x150mm
Series HK-400
Gel material Styrene divinylbenzene copolymer
Quantity 1 pc
Chemistry Producers Term HK
Recommended flow rate 0.3 to 1.0 mL/min
Max. usable flow rate 2.0 mL/min
Max. usable pressure 25 MPa (250 bar)
Usable solvents (in addition to THF) Chloroform
Dimethylformamide (DMF)
Toluene
Hexafluoroisopropanol (HFIP)
Shipping solvent Tetrahydrofulan (THF)
Housing material steel
Matrix Polymer
Mode of Separation Organic Size Exclusion Chromatography (SEC) 
Gel permeation chromatography (GPC)
Internal Diameter 4.6 mm
Length 150 mm
Number Theoretical Plates >9000
Brand GPC
Particle Morphology spherical, porous
Target molecular weight range 100 - 1,500
Exclusion limit 2,000
MW range 100 - 1,500
Particle Size 3 µm
Pore Size 50 Å
Technology GPC
Max. usable temperature ≤ 60°C
USP L21

Monodisperse small particles can obtain low pressure at high flow rate. Therefore the analysis time can be reduced to about one sixth of standard column's analysis time without UHPLC devices. Furthermore, The amount solvent used can be reduced to about a sixth.

HK-400 Series Features

  • Newly developed styrene divinylbenzene copolymer monodisperse particles for 2022
  • Analysis time is reduced to about a sixth of conventional column's analysis time
  • Low column pressure even under high flow rate does not require a UHPLC system
  • The amount of solvent used is reduced to about a sixth
  • HK-402 (exclusion limit: 20,000) and HK-406 (exclusion limit: 10,000,000) newly added to the series
  • Fulfills USP-NF L21 requirements - A rigid, spherical styrenedivinylbenzene copolymer, 3 to 30 μm in diameter.

Possible HK-400 series Applications:

  • Organic SEC (GPC) - Application: General polymers - Eluent: THF
  • Organic SEC (GPC) - Application: General polymers - Eluent: Chloroform
  • Organic SEC (GPC) - Application: Polar polymers (Polyimides etc.) - Eluent: DMF
  • Organic SEC (GPC) - Application: Engineering plastics (Polyamides etc.) - Eluent: HFIP

Possible HK-401 Column Applications:

  • Epoxy Resin (4) (Comparison of HK-404L and HK-404L + HK-401)
  • Polystyrene Standards (24) (HK-401)

[HK-400 series] Shipping solvent: Tetrahydrofulan (THF) | Standard columns | Base Material: Styrene divinylbenzene copolymer

HK-400 series is recommended to be used with semi-micro type devices.

Product Code Product Name Plate Number
(TP/column)
Particle Size
(μm)
Pore Size
(Å)
Column Size (mm)
I.D. x Length
F6025010 GPC HK-401 ≥ 9,000 3 50 4.6 x 150
F6025020 GPC HK-402 ≥ 12,000 3 300 4.6 x 150
F6025030 GPC HK-403 ≥ 9,000 3.5 550 4.6 x 150
F6026040 GPC HK-404L ≥ 9,000 3.5 2,000 4.6 x 150
F6025050 GPC HK-405 ≥ 7,000 3 5,000 4.6 x 150
F6025060 GPC HK-406 ≥ 5,000 6.5 10,000 4.6 x 150

HK-404L is a mixed-gel column capable of analyzing samples over a wide range of molecular weight distribution.

Guard filter for HK series - Attach directly to the analytical column

Product Code Product Name Contents
F6700200 GPC HK-G One holder and one filter
F6700100 GPC HK-G filter 3 filters

Removes sample-origin insoluble components.

 


  • Model: F6025010
  • Manufactured by: Showa Denko