Precolumn Solvent Filter Assembly for 1/16” OD Tubing, 0.5 μm, 10-32 Coned Threads, 0.84 μL Swept Volume, Stainless Steel
Includes: replaceable Frit A-102
Product Number: A-318
Categories: Filters, Filters & Frits, Fluidic Connections, Precolumn Filters
This Upchurch Scientific, IDEX Health & Science, Biotech Fluidics Stainless Steel Precolumn Filter is ideal for higher pressure applications and to help prevent particulate contamination. It has a porosity .5µm and a swept volume of 84uL and comes with the replaceable Frit A-102.
Related Products:
- U-400 - 316 Stainless Steel Male Nut 10-32 Coned, for 1/16" OD Single
- U-401 - Stainless Steel Ferrule 10-32 Coned, for 1/16" OD Single
Specifications:
Porosity µm | 0.5 |
---|---|
Swept Volume µL | 0.84 |
Thru hole (in) | 0.010 |
Thread Port Configuration Flat-Bottom | 10-32 |
Material | Stainless Steel |
Precolumn Filters
These economical Precolumn Filters offer secure protection for analytical columns in HPLC and UHPLC. We offer traditional versions that can successfully connect tubing on both sides and our direct-connect versions attach to the inlet port of most standard columns. All versions feature a 10-32 coned ports for 1/16” OD tubing.
Standard Precolumn Filters
- Economical protection for larger columns and injections
- Traditional versions connect tubing on both sides
- Direct-connect versions attach to the inlet port of most standard columns
- All versions feature 10-32 coned ports for 1/16” OD tubing
These are designed to protect columns by filtering out particulate matter originating from the sample or from rotor seal wear.
- Assemblies that begin with the letter “A” are traditional versions for standard HPLC
- Assemblies that begin with “VHP” are direct-connect versions for UHPLC applications
- Versions that begin with “9085” are direct-connect for standard HPLC and must be used with polymer fittings
Part No. | Description | Porosity | For Tubing Size | Threads | Includes | Swept Volume* | Pressure Rating |
STANDARD PRECOLUMN FILTERS | |||||||
A-315 | Solvent Filter Assembly | 2 μm | 1/16” OD | 10-32 Coned | (1) A-101 | 1.4 μL | 6,000 psi (414 bar) |
A-318 | Solvent Filter Assembly | 0.5 μm | 1/16” OD | 10-32 Coned | (1) A-102 | 0.84 μL | 6,000 psi (414 bar) |
A-101 | Replacement Frits, SS | 2 μm | N/A | — | — | 0.74 μL | N/A |
A-102 | Replacement Frits, SS | 0.5 μm | N/A | — | — | 0.61 μL | N/A |
VHP-550 | Precolumn VHP Filter | 0.5 μm | 1/16” OD | 10-32 Coned | (5) VHP-551 | 1.9 μL | 20,000 psi (1,380 bar) |
VHP-555 | Precolumn VHP Filter | 0.2 μm | 1/16” OD | 10-32 Coned | (5) VHP-556 | 1.8 μL | 20,000 psi (1,380 bar) |
VHP-551 | Replacement Precolumn VHP Frit Assembly | 0.5 μm | N/A | N/A | N/A | 1.9 μL | N/A |
VHP-556 | Replacement Precolumn VHP Frit Assembly | 0.2 μm | N/A | N/A | N/A | 1.8 μL | N/A |
9085-05-10 | ColumnSaver Precolumn Filter, with SST frit | 0.5 μm | 1/16” OD | 10-32 Coned | N/A | 3.1 μL | 6,000 psi (414 bar) |
9085-20-10 | ColumnSaver Precolumn Filter, with SST frit | 2 μm | 1/16” OD | 10-32 Coned | N/A | 3.1 μL | 6,000 psi (414 bar) |
BIOCOMPATIBLE PRECOLUMN FILTERS | |||||||
A-355 | Solvent Filter Assembly, Biocompatible | 2 μm | — | 10-32 Coned | (1) A-700 | 1.4 μL | 5,000 psi (345 bar) |
A-356 | Solvent Filter Assembly, Biocompatible | 0.5 μm | — | 10-32 Coned | (1) A-701 | 1.3 μL | 5,000 psi (345 bar) |
A-700 | Replacement Frit, PEEK Polymer | 2 μm | — | — | — | 0.74 μL | N/A |
A-701 | Replacement Frit, PEEK Polymer | 0.5 μm | — | — | — | 0.61 μL | N/A |
SST = Stainless Steel
*Swept volumes include/reflect theoretical frit volume values.
- Model: A-318
- Manufactured by: Upchurch Scientific