Welch Materials Ultisil LP-C8 Columns

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments.

Ultisil Series HPLC Columns are based on ultra-pure (purity > 99.999%) spherical and totally porous silica, unique bonding chemistry and proprietary surface modification techniques, producing excellent peak shape, column efficiency and exceptional lot-to-lot reproducibility. Ultisil column is the best choice for method development. owing to complete bonding chemistries and stable performance.

Features

  • Ultra-pure spherical porous silica, purity > 99.999%
  • Wide pH range: 2.0-8.0
  • High efficiency: theoretical plate > 80000/m
  • Excellent peak symmetry: tailing factor=0.95~1.05
  • Exceptional lot-to-lot reproducibility


Item Name Product Image Price

Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 4.6 x 300 mm - H00209-31044

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments. Quantity: 1 pcs/pk
Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 4.6 x 300 mm - H00209-31044 £528.00
New
Buy Now

Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 4.6 x 33 mm - H00209-31071

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments. Quantity: 1 pcs/pk
Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 4.6 x 33 mm - H00209-31071 £458.00
New
Buy Now

Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 4.6 x 50 mm - H00209-31037

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments. Quantity: 1 pcs/pk
Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 4.6 x 50 mm - H00209-31037 £424.00
New
Buy Now

Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 4.6 x 75 mm - H00209-31038

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments. Quantity: 1 pcs/pk
Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 4.6 x 75 mm - H00209-31038 £440.00
New
Buy Now

Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 6.0 x 150 mm - H00209-31053

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments. Quantity: 1 pcs/pk
Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 6.0 x 150 mm - H00209-31053 £672.00
New
Buy Now

Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 6.0 x 250 mm - H00209-31054

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments. Quantity: 1 pcs/pk
Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 6.0 x 250 mm - H00209-31054 £712.00
New
Buy Now

Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 6.5 x 150 mm - H00209-31045

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments. Quantity: 1 pcs/pk
Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 6.5 x 150 mm - H00209-31045 £672.00
New
Buy Now

Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 6.5 x 250 mm - H00209-31046

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments. Quantity: 1 pcs/pk
Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 6.5 x 250 mm - H00209-31046 £712.00
New
Buy Now

Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 7.8 x 100 mm - H00209-31049

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments. Quantity: 1 pcs/pk
Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 7.8 x 100 mm - H00209-31049 £752.00
New
Buy Now

Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 7.8 x 150 mm - H00209-31050

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments. Quantity: 1 pcs/pk
Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 7.8 x 150 mm - H00209-31050 £840.00
New
Buy Now

Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 7.8 x 250 mm - H00209-31051

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments. Quantity: 1 pcs/pk
Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 120 Å, 7.8 x 250 mm - H00209-31051 £968.00
New
Buy Now

Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 300 Å, 4.6 x 150 mm - H00209-33041

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments. Quantity: 1 pcs/pk
Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 300 Å, 4.6 x 150 mm - H00209-33041 £528.00
New
Buy Now

Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 300 Å, 4.6 x 250 mm - H00209-33043

Ultisil LP-C8 column ultilizes the same bonding technology as LP-C18, providing a classic reversed-phase retention mechanism. It is the preferred C8 column for strongly acidic and high-aqueous mobile phase environments. Quantity: 1 pcs/pk
Welch Materials Ultisil LP-C8 HPLC Column, 5 µm, 300 Å, 4.6 x 250 mm - H00209-33043 £552.00
New
Buy Now