Hellma Macro Absorption Cuvettes

Hellma Macro Absorption Cells with PTFE lid or stopper

Cuvettes for absorbance and fluorescence measurements
Hellma Analytics produces a wide range of cuvettes for use in spectroscopy and cytometry with optical path lengths spanning 0.01 mm to 100 mm and above. Thanks to their stability, maximum precision and reliability when used for absorbance and fluorescence measurements, Hellma cuvettes work exceptionally well in a wide range of areas in the lab. With a surface flatness of 1 μm, our quartz windows set a benchmark in cuvette production.

What’s more, the function-optimized design with beveled edges and corners protects against the risk of damage caused by splitting and assists users in their daily work. On request, we are able to produce custom models designed for specific areas of application.

Measuring of cuvette transmission
If required, cuvettes can be spectrally calibrated into sets with equal transmission values (measurement uncertainty
±1%). These cuvettes are given a three-digit calibration code containing coded data about the material and the transmission at a wavelength typical for the cuvette material.

Polarimetric checking of cuvettes
Cuvettes with an inside width greater than 5 mm can be polarimetrically checked on request. They are marked with a “P” and delivered with a test certificate confirming that the rotation of the polarization plane does not exceed
0.01 degrees.

ADVANTAGES

  • Extremely high parallelism of the windows with a maximum tolerance of ± 0.01 mm
  • Exceptional optical path length accuracy down to 0.003 mm (3 μm) for high dimensional accuracy and reproducible measurements results
  • Unique surface flatness of the optical windows of 0.001 mm (1 μm)
  • Very high temperature stability and chemical resistance due to thermal bonding of individual components (effectively monolithic)
  • Guaranteed transmission of at least 82% from 200 nm to 3500 nm depending on the material


Item Name Product Image Price

Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 350 ul, 1 mm Light Path, 1/Pk - 100-1-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with glass lid for Visible spectrophotometers, Special Optical Glass 320nm-2500nm, 350μl, 1mm Light Path, 45 x 12.5 x 3.5 mm, 1/Pk Product Number: 100-1-20 Hellma Analytics produces a wide...
Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 350 ul, 1 mm Light Path, 1/Pk - 100-1-20
Live chat below or contact us for latest price.
... more info

Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 350 ul, 1 mm Light Path, 2/Pk - 100-1-K-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with glass lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 350μl, 1mm Optical Path, 45 x 12.5 x 3.5 mm, 2/Pk (Pair) Product Number: 100-1-K-20 Hellma...
Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 350 ul, 1 mm Light Path, 2/Pk - 100-1-K-20
Live chat below or contact us for latest price.
... more info

Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 700 ul, 2 mm Light Path, 1/Pk - 100-2-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with glass lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 700µl, 2mm Optical Path, 45 x 12.5 x 4.5 mm, 1/Pk  Product Number: 100-2-20 Hellma Analytics...
Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 700 ul, 2 mm Light Path, 1/Pk - 100-2-20 £86.05Buy Now

Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 700 ul, 2 mm Light Path, 2/Pk - 100-2-K-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with glass lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 700 ul, 2 mm Optical Path, 45 x 12.5 x 4.5 mm, 2/Pk (Pair)  Product Number: 100-2-K-20 Hellma...
Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 700 ul, 2 mm Light Path, 2/Pk - 100-2-K-20
Live chat below or contact us for latest price.
... more info

Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 1750 ul, 5 mm Light Path, 1/Pk - 100-5-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with PTFE lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 1750μl, 5mm Optical Path, 45 x 12.5 x 7.5 mm, 1/Pk Product Number: 100-5-20 Hellma...
Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 1750 ul, 5 mm Light Path, 1/Pk - 100-5-20
Live chat below or contact us for latest price.
... more info

Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 1750 ul, 5 mm Light Path, 2/Pk - 100-5-K-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with PTFE lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 1750 ul, 5 mm Optical Path, 45 x 12.5 x 7.5 mm, 2/Pk (Pair) Product Number: 100-5-K-20 Hellma...
Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 1750 ul, 5 mm Light Path, 2/Pk - 100-5-K-20
Live chat below or contact us for latest price.
... more info

Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 3500 ul, 10 mm Light Path, 1/Pk - 100-10-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with PTFE lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 3500μl, 10mm Optical Path, 45 x 12.5 x 12.5 mm, 1/Pk Product Number: 100-10-20 Hellma...
Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 3500 ul, 10 mm Light Path, 1/Pk - 100-10-20 £60.44Buy Now

Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 3500 ul, 10 mm Light Path, 2/Pk - 100-10-K-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with PTFE lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 3500 ul, 10 mm Optical Path, 45 x 12.5 x 12.5 mm, 2/Pk (Pair) Product Number: 100-10-K-20...
Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 3500 ul, 10 mm Light Path, 2/Pk - 100-10-K-20 £144.53Buy Now

Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 7000 ul, 20 mm Light Path, 1/Pk - 100-20-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with PTFE lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 7000μl, 20mm Optical Path, 45 x 12.5 x 22.5 mm, 1/Pk Product Number: 100-20-20 Hellma...
Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 7000 ul, 20 mm Light Path, 1/Pk - 100-20-20 £78.38Buy Now

Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 7000 ul, 20 mm Light Path, 2/Pk - 100-20-K-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with PTFE lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 7000μl, 20mm Optical Path, 45 x 12.5 x 22.5 mm, 2/Pk (Pair) Product Number: 100-20-K-20...
Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 7000 ul, 20 mm Light Path, 2/Pk - 100-20-K-20
Live chat below or contact us for latest price.
... more info

Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 14000 ul, 40 mm Light Path, 1/Pk - 100-40-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with PTFE lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 14000μl, 40mm Optical Path, 45 x 12.5 x 42.5 mm, 1/Pk Product Number: 100-40-20 Hellma...
Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 14000 ul, 40 mm Light Path, 1/Pk - 100-40-20 £99.92Buy Now

Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 14000 ul, 40 mm Light Path, 2/Pk - 100-40-K-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with PTFE lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 14000μl, 40mm Optical Path, 45 x 12.5 x 42.5 mm, 2/Pk (Pair) Product Number: 100-40-K-20...
Hellma 100-OS Macro Absorption Cell with PTFE lid, Special Optical Glass, 320-2500 nm, 14000 ul, 40 mm Light Path, 2/Pk - 100-40-K-20
Live chat below or contact us for latest price.
... more info

Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 17500 ul, 50 mm Light Path, 1/Pk - 100-50-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with glass lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 17500μl, 50mm Optical Path, 45 x 12.5 x 52.5 mm, 1/Pk Product Number: 100-50-20 Hellma...
Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 17500 ul, 50 mm Light Path, 1/Pk - 100-50-20 £123.20Buy Now

Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 17500 ul, 50 mm Light Path, 2/Pk - 100-50-K-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with glass lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 17500μl, 50mm Optical Path, 45 x 12.5 x 52.5 mm, 2/Pk (Pair) Product Number: 100-50-K-20...
Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 17500 ul, 50 mm Light Path, 2/Pk - 100-50-K-20 £270.63Buy Now

Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 35000 ul, 100 mm Light Path, 1/Pk - 100-100-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with glass lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 35000 μl, 100 mm Optical Path, 45 x 12.5 x 102.5 mm, 1/Pk Product Number: 100-100-20...
Hellma 100-OS Macro Absorption Cell with glass lid, Special Optical Glass, 320-2500 nm, 35000 ul, 100 mm Light Path, 1/Pk - 100-100-20 £207.59Buy Now

Hellma 100-OS Macro Absorption Cell with Glass lid, Special Optical Glass, 320-2500 nm, 35000 ul, 100 mm Light Path, 2/Pk - 100-100-K-20

Absorption Cells Hellma 100-OS Macro Absorption Cell with Glass lid for Visible spectrophotometers, Special Optical Glass Window 320nm-2500nm, 35000µl, 100mm Optical Path, 45 x 12.5 x 102.5 mm, 2/Pk (Pair) Product Number: 100-100-K-20...
Hellma 100-OS Macro Absorption Cell with Glass lid, Special Optical Glass, 320-2500 nm, 35000 ul, 100 mm Light Path, 2/Pk - 100-100-K-20
Live chat below or contact us for latest price.
... more info

Hellma 100-QS Macro Absorption Cell with glass lid, Quartz SUPRASIL Glass, 200-2500 nm, 350 ul, 1 mm Light Path, 1/Pk - 100-1-40

Absorption Cells Hellma 100-QS Macro Absorption Cell with glass lid for UV/VIS spectrophotometers, Quartz SUPRASIL® High Performance Window 200nm-2500nm, 350μl, 1mm Optical Path, 45 x 12.5 x 3.5 mm, 1/Pk Product Number:...
Hellma 100-QS Macro Absorption Cell with glass lid, Quartz SUPRASIL Glass, 200-2500 nm, 350 ul, 1 mm Light Path, 1/Pk - 100-1-40 £121.25Buy Now

Hellma 100-QS Macro Absorption Cell with glass lid, Quartz SUPRASIL Glass, 200-2500 nm, 350 ul, 1 mm Light Path, 2/Pk - 100-1-K-40

Absorption Cells Hellma 100-QS Macro Absorption Cell with glass lid  for UV/VIS spectrophotometers, Quartz SUPRASIL® High Performance Window 200nm-2500nm, 350μl, 1mm Optical Path, 45 x 12.5 x 3.5 mm, 2/Pk (Pair) Product...
Hellma 100-QS Macro Absorption Cell with glass lid, Quartz SUPRASIL Glass, 200-2500 nm, 350 ul, 1 mm Light Path, 2/Pk - 100-1-K-40 £264.81Buy Now

Hellma 100-QS Macro Absorption Cell with glass lid, Quartz SUPRASIL Glass, 200-2500 nm, 700 ul, 2 mm Light Path, 1/Pk - 100-2-40

Absorption Cells Hellma 100-QS Macro Absorption Cell with glass lid for UV/VIS spectrophotometers, Quartz SUPRASIL® High Performance Window 200nm-2500nm, 700μl, 2mm Optical Path, 45 x 12.5 x 4.5 mm, 1/Pk Product Number: 100-2-40...
Hellma 100-QS Macro Absorption Cell with glass lid, Quartz SUPRASIL Glass, 200-2500 nm, 700 ul, 2 mm Light Path, 1/Pk - 100-2-40 £121.25Buy Now

Hellma 100-QS Macro Absorption Cell with glass lid, Quartz SUPRASIL Glass, 200-2500 nm, 700 ul, 2 mm Light Path, 2/Pk - 100-2-K-40

Absorption Cells Hellma 100-QS Macro Absorption Cell with glass lid for UV/VIS spectrophotometers, Quartz SUPRASIL® Glass High Performance Window 200nm-2500nm, 700μl, 2mm Optical Path, 45 x 12.5 x 4.5 mm, 2/Pk (Pair) Product...
Hellma 100-QS Macro Absorption Cell with glass lid, Quartz SUPRASIL Glass, 200-2500 nm, 700 ul, 2 mm Light Path, 2/Pk - 100-2-K-40