Part Number: EXL-119-1502U
Title: Avantor® ACE® Excel® C18-AR Analytical HPLC Column, 3 µm, 100 Å, 2.1 x 150 mm, 1pk - EXL-119-1502U
The Avantor® ACE® Excel® C18-AR phase utilises a specially developed ligand combining a C18 chain with integral phenyl functionality, thus combining the benefits of both C18 and phenyl characteristics into a single phase. This can be used for ‘standard’ C18 column separations, but is additionally recommended for separations that involve compounds containing aromatic functionality.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 to 5 µm) and complementary phases
- Ultra low bleed to ensure LC/MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
These columns are made from stainless steel.
Title: Avantor® ACE® Excel® C18-AR Analytical HPLC Column, 3 µm, 100 Å, 2.1 x 150 mm, 1pk - EXL-119-1502U
The Avantor® ACE® Excel® C18-AR phase utilises a specially developed ligand combining a C18 chain with integral phenyl functionality, thus combining the benefits of both C18 and phenyl characteristics into a single phase. This can be used for ‘standard’ C18 column separations, but is additionally recommended for separations that involve compounds containing aromatic functionality.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 to 5 µm) and complementary phases
- Ultra low bleed to ensure LC/MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
These columns are made from stainless steel.
Specifications:
| Column format | Analytical |
| Phase | C18-AR |
| Pore size | 100 Å |
| Particle size | 3 µm |
| Ø int. | 2.10 mm |
| Length | 150 mm |
| Pk | 1 |
| P/N | EXL-119-1502U |
| Carbon load | 15.5% |
| Endcapped | Yes |
| Max. pressure | 1000 bar |
| pH range | 2 - 8 |
| Surface area | 300 m²/g |
| USP code | L1 |
Guard cartridges, ACE UHPLC guard holder may be required
| Description | Column format | Phase | Particle size | Pk | P/N |
|---|---|---|---|---|---|
| For analytical columns (4.0 - 4.6 mm ID) | Guard cartridge | C18-AR | 2 µm | 3 | ACE-1P9-GD4U |
| For analytical UHPLC columns (2.1 - 3.0 mm ID) | Guard cartridge | C18-AR | 1.7 µm | 3 | ACE-1P9-GD2U |
Guard holders and accessories
| Description | Pk | P/N |
|---|---|---|
| Replacement ferrules | 10 | F0001 |
| UHPLC guard cartridge holder for 2.1 to 4.6 mm ID columns | 1 | H0011 |
Method validation kit
| Column format | Phase | Pore size | Particle size | Ø int. | Length | Pk | P/N |
|---|---|---|---|---|---|---|---|
| Analytical | C18-AR | 100 Å | 3 µm | 4.60 mm | 250 mm | 1 KIT | EXL1192546UMVK |
- Model: EXL-119-1502U
- Manufactured by: Avantor