Part Number: EXL-1710-1003U
Title: Avantor® ACE® Excel® C18-PFP Analytical HPLC Column, 1.7 µm, 100 Å, 3 x 100 mm, 1pk - EXL-1710-1003U
Avantor® ACE® Excel® C18-PFP phase utilizes a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 to 5 µm) and complementary phases
- Also useful for analytes with π-bonding or electron or proton donor groups
- Ultra-low bleed to ensure LC/MS compatibility
- Suitable for use with 100% aqueous mobile phases
- Method validation kits contain three different batches of the same phase - available on request
Due to its integral pentafluoro phenyl functionality, Avantor® ACE® C18-PFP is also recommended for separations that involve halogenated aromatic compounds, Regio isomers, and those analytes with differing shape constraints.
These columns are made from stainless steel.
Title: Avantor® ACE® Excel® C18-PFP Analytical HPLC Column, 1.7 µm, 100 Å, 3 x 100 mm, 1pk - EXL-1710-1003U
Avantor® ACE® Excel® C18-PFP phase utilizes a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 to 5 µm) and complementary phases
- Also useful for analytes with π-bonding or electron or proton donor groups
- Ultra-low bleed to ensure LC/MS compatibility
- Suitable for use with 100% aqueous mobile phases
- Method validation kits contain three different batches of the same phase - available on request
Due to its integral pentafluoro phenyl functionality, Avantor® ACE® C18-PFP is also recommended for separations that involve halogenated aromatic compounds, Regio isomers, and those analytes with differing shape constraints.
These columns are made from stainless steel.
Specifications:
Column format | Analytical |
Phase | C18-PFP |
Pore size | 100 Å |
Particle size | 1.7 µm |
Ø int. | 3.00 mm |
Length | 100 mm |
Pk | 1 |
P/N | EXL-1710-1003U |
Carbon load | 14.3% |
Endcapped | Yes |
Max. pressure | 1000 bar |
pH range | 2 - 8 |
Surface area | 300 m²/g |
USP code | L1 |
Guard cartridges, ACE guard holder may be required
Description | Column format | Phase | Particle size | Pk | P/N |
---|---|---|---|---|---|
For analytical UHPLC columns (2.1 - 3.0 mm ID) | Guard cartridge | C18-PFP | 1.7 µm | 3 | ACE-1P10-GD2U |
Guard holders and accessories
Description | Pk | P/N |
---|---|---|
UHPLC guard cartridge holder for 2.1 to 4.6 mm ID columns | 1 | H0011 |
Replacement ferrules | 10 | F0001 |
- Model: EXL-1710-1003U
- Manufactured by: Avantor