Part Number: EXL-125-1502U
Title: Avantor® ACE® Excel® Phenyl Analytical HPLC Column, 5 µm, 100 Å, 2.1 x 150 mm, 1pk - EXL-125-1502U
These Avantor® ACE® Excel® Phenyl columns provide great reproducibility and column lifetime. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Offers strong π-π interactions
- Ideal for analytes with π-bonding, electron withdrawing or delocalised groups
- Wide range of particle sizes available (2 µm, 3 µm and 5 µm) and complementary phases
- Method validation kits contain three different batches of the same phase - available on request
These columns are designed for a wide range of chromatographic applications, to provide great performance with acidic, basic and neutral molecules.
Title: Avantor® ACE® Excel® Phenyl Analytical HPLC Column, 5 µm, 100 Å, 2.1 x 150 mm, 1pk - EXL-125-1502U
These Avantor® ACE® Excel® Phenyl columns provide great reproducibility and column lifetime. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative.
- Ultra high purity, base deactivated silica with exceptional reproducibility
- Offers strong π-π interactions
- Ideal for analytes with π-bonding, electron withdrawing or delocalised groups
- Wide range of particle sizes available (2 µm, 3 µm and 5 µm) and complementary phases
- Method validation kits contain three different batches of the same phase - available on request
These columns are designed for a wide range of chromatographic applications, to provide great performance with acidic, basic and neutral molecules.
Specifications:
Column format | Analytical |
Phase | Phenyl |
Pore size | 100 Å |
Particle size | 5 µm |
Ø int. | 2.10 mm |
Length | 150 mm |
Pk | 1 |
P/N | EXL-125-1502U |
Carbon load | 9.5% |
Endcapped | Yes |
Max. pressure | 1000 bar |
pH range | 2 - 8 |
Surface area | 300 m²/g |
USP code | L11 |
Guard cartridges, ACE UHPLC guard holder may be required
Description | Column format | Phase | Pore size | Particle size | Pk | P/N |
---|---|---|---|---|---|---|
For analytical columns (I.Ø 3.0, 4.0, 4.6 mm) | Guard cartridge | Phenyl | 100 Å | 5 µm | 5 | ACE-125-0103GD |
For analytical columns (I.Ø 2.1 mm) | Guard cartridge | Phenyl | 100 Å | 5 µm | 5 | ACE-125-0102GD |
Guard holders and accessories
Description | Pk | P/N |
---|---|---|
Column coupler (for use with H0001/H0002) | 1 | C0001 |
1 cm stand-alone cartridge holder for 1.0 to 4.6 mm ID columns | 1 | H0001 |
- Model: EXL-125-1502U
- Manufactured by: Avantor