Part Number: ACE-1212-1030
Title: Avantor® ACE® C18-Amide Preparative HPLC Column, 5 µm, 100 Å, 30 x 100 mm, 1pk - ACE-1212-1030
Avantor® ACE® C18-Amide is a uniquely designed stationary phase offering improved retention of polar compounds, enhanced phenolic resolution and alternative selectivity to C18 bonded columns. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (2.0 to 10 µm) and complementary phases
- Low bleed for UV and LC/MS compatibility
- C18 hydrophobic plus Amide interactions, compatible with 100% aqueous conditions
- Method validation kits contain three different batches of the same phase - available on request
The special design of the ACE® C18-Amide ligand incorporates an extended alkyl chain spacer between the silica surface and amide polar group, which gives extra phase stability.
Title: Avantor® ACE® C18-Amide Preparative HPLC Column, 5 µm, 100 Å, 30 x 100 mm, 1pk - ACE-1212-1030
Avantor® ACE® C18-Amide is a uniquely designed stationary phase offering improved retention of polar compounds, enhanced phenolic resolution and alternative selectivity to C18 bonded columns. These stainless steel columns are available in a wide range of particle sizes and dimensions from capillary to preparative.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (2.0 to 10 µm) and complementary phases
- Low bleed for UV and LC/MS compatibility
- C18 hydrophobic plus Amide interactions, compatible with 100% aqueous conditions
- Method validation kits contain three different batches of the same phase - available on request
The special design of the ACE® C18-Amide ligand incorporates an extended alkyl chain spacer between the silica surface and amide polar group, which gives extra phase stability.
Specifications:
Column format | Preparative |
Phase | C18-Amide |
Column hardware | Stainless steel |
Pore size | 100 Å |
Particle size | 5 µm |
Ø int. | 30.00 mm |
Length | 100 mm |
Connection | 1/16" connection |
Pk | 1 |
P/N | ACE-1212-1030 |
Carbon load | 16.4% |
Endcapped | Yes |
Max. pressure | 275 bar |
pH range | 2 - 8 |
Surface area | 300 m²/g |
USP code | L1 |
Guard cartridge holders and accessories
Description | Pk | P/N |
---|---|---|
Column coupler (for use with H0009) | 1 | C0002 |
Column coupler (for use with H0001/H0002) | 1 | C0001 |
Preparative guard cartridge holder for 30 mm ID columns | 1 | H0009 |
Semi-preparative cartridge holder for 7,75 to 21.2 mm ID columns | 1 | H0002 |
1 cm stand-alone cartridge holder for 1.0 to 4.6 mm ID columns | 1 | H0001 |
Guard cartridges, ACE HPLC guard holder may be required
Description | Column format | Phase | Pore size | Particle size | Pk | P/N |
---|---|---|---|---|---|---|
For semi-preparative columns (I-Ø 7,75, 10.0, 21.2 mm) | Guard cartridge | C18-Amide | 100 Å | 5 µm | 3 | ACE-12120110GD |
For analytical columns (I-Ø 3.0, 4.0, 4.6 mm) | Guard cartridge | C18-Amide | 100 Å | 5 µm | 5 | ACE-1212-0103GD |
For preparative columns (I-Ø 30.0 mm) | Guard cartridge | C18-Amide | 100 Å | 5 µm | 3 | ACE12120120GD |
- Model: ACE-1212-1030