Part Number: ACE-1110-1546
Title: Avantor® ACE® C18-PFP Analytical HPLC Column, 3 µm, 100 Å, 4.6 x 150 mm, 1pk - ACE-1110-1546
Avantor® ACE® C18-PFP phase utilises a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 µm to 10 µm) and complementary phases
- Also useful for analytes with π-bonding or electron or proton donor groups
- Ultra-low bleed to ensure LC-MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
Due to its integral pentafluorophenyl functionality, Avantor® ACE® C18-PFP is also recommended for separations that involve halogenated aromatic compounds, regioisomers, and those analytes with differing shape constraints.
These columns are made from stainless steel.
Title: Avantor® ACE® C18-PFP Analytical HPLC Column, 3 µm, 100 Å, 4.6 x 150 mm, 1pk - ACE-1110-1546
Avantor® ACE® C18-PFP phase utilises a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 µm to 10 µm) and complementary phases
- Also useful for analytes with π-bonding or electron or proton donor groups
- Ultra-low bleed to ensure LC-MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
Due to its integral pentafluorophenyl functionality, Avantor® ACE® C18-PFP is also recommended for separations that involve halogenated aromatic compounds, regioisomers, and those analytes with differing shape constraints.
These columns are made from stainless steel.
Specifications:
Column format | Analytical |
Phase | C18-PFP |
Pore size | 100 Å |
Particle size | 3 µm |
Ø int. | 4.60 mm |
Length | 150 mm |
Connection | 1/16" connection |
Pk | 1 |
P/N | ACE-1110-1546 |
Carbon load | 14.3% |
Endcapped | Yes |
Max. pressure | 275 bar |
pH range | 2 - 8 |
Surface area | 300 m²/g |
USP code | L1 |
Guard cartridges, ACE HPLC guard holder may be required
Description | Column format | Phase | Pore size | Particle size | Pk | P/N |
---|---|---|---|---|---|---|
For analytical columns (I-Ø 3.0, 4.0, 4.6 mm) | Guard cartridge | C18-PFP | 100 Å | 3 µm | 5 | ACE-1110-0103GD |
For microbore columns (I-Ø 2.1 mm) | Guard cartridge | C18-PFP | 100 Å | 3 µm | 5 | ACE-1110-0102GD |
For microbore columns (I-Ø 1.0 mm) | Guard cartridge | C18-PFP | 100 Å | 3 µm | 5 | ACE-1110-0101GD |
Guard holders and accessories
Description | Pk | P/N |
---|---|---|
Column coupler (for use with H0001/H0002) | 1 | C0001 |
1 cm stand-alone cartridge holder for 1.0 to 4.6 mm ID columns | 1 | H0001 |
Method validation kits
Column format | Phase | Pore size | Particle size | Ø int. | Length | Connection | Pk | P/N |
---|---|---|---|---|---|---|---|---|
Analytical | C18-PFP | 100 Å | 3 µm | 4.60 mm | 150 mm | 1/16" connection | 1 KIT | ACE11101546MVK |
Analytical | C18-PFP | 100 Å | 3 µm | 3.00 mm | 150 mm | 1/16" connection | 1 KIT | ACE11101503MVK |
- Model: ACE-1110-1546
- Manufactured by: Avantor