Part Number: ACE-1210-0502
Title: Avantor® ACE® C18-PFP Analytical HPLC Column, 5 µm, 100 Å, 2.1 x 50 mm, 1pk - ACE-1210-0502
Avantor® ACE® C18-PFP phase utilises a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 µm to 10 µm) and complementary phases
- Also useful for analytes with π-bonding or electron or proton donor groups
- Ultra-low bleed to ensure LC/MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
Due to its integral pentafluorophenyl functionality, Avantor® ACE® C18-PFP is also recommended for separations that involve halogenated aromatic compounds, regioisomers, and those analytes with differing shape constraints.
These columns are made from stainless steel.
Title: Avantor® ACE® C18-PFP Analytical HPLC Column, 5 µm, 100 Å, 2.1 x 50 mm, 1pk - ACE-1210-0502
Avantor® ACE® C18-PFP phase utilises a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 µm to 10 µm) and complementary phases
- Also useful for analytes with π-bonding or electron or proton donor groups
- Ultra-low bleed to ensure LC/MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
Due to its integral pentafluorophenyl functionality, Avantor® ACE® C18-PFP is also recommended for separations that involve halogenated aromatic compounds, regioisomers, and those analytes with differing shape constraints.
These columns are made from stainless steel.
Specifications:
| Column format | Analytical | 
| Phase | C18-PFP | 
| Pore size | 100 Å | 
| Particle size | 5 µm | 
| Ø int. | 2.10 mm | 
| Length | 50 mm | 
| Pk | 1 | 
| P/N | ACE-1210-0502 | 
| Carbon load | 14.3% | 
| Endcapped | Yes | 
| Max. pressure | 275 bar | 
| pH range | 2 - 8 | 
| Surface area | 300 m²/g | 
| USP code | L1 | 
Guard cartridges, ACE HPLC guard holder may be required
| Description | Column format | Phase | Pore size | Particle size | Pk | P/N | 
|---|---|---|---|---|---|---|
| For semi-preparative columns (I-Ø 7,75, 10.0, 21.2 mm) | Guard cartridge | C18-PFP | 100 Å | 5 µm | 3 | ACE-1210-0110GD | 
| For analytical columns (I-Ø 3.0, 4.0, 4.6 mm) | Guard cartridge | C18-PFP | 100 Å | 5 µm | 5 | ACE-1210-0103GD | 
| For analytical columns (I-Ø 2.1 mm) | Guard cartridge | C18-PFP | 100 Å | 5 µm | 5 | ACE-1210-0102GD | 
| For preparative columns (I-Ø 30 mm) | Guard cartridge | C18-PFP | 100 Å | 5 µm | 3 | ACE12100120GD | 
Guard holders and accessories
| Description | Pk | P/N | 
|---|---|---|
| Column coupler (for use with H0009) | 1 | C0002 | 
| Column coupler (for use with H0001/H0002) | 1 | C0001 | 
| Preparative guard cartridge holder for 30 mm ID columns | 1 | H0009 | 
| Semi-preparative cartridge holder for 7,75 to 21.2 mm ID columns | 1 | H0002 | 
Method validation kits
| Column format | Phase | Pore size | Particle size | Ø int. | Length | Pk | P/N | 
|---|---|---|---|---|---|---|---|
| Analytical | C18-PFP | 100 Å | 5 µm | 4.60 mm | 250 mm | 1 KIT | ACE12102546MVK | 
- Model: ACE-1210-0502
 - Manufactured by: Avantor
 

					
											