Biotech SmartSaver™ USB Solvent Recycler
Biotech SmartSaver™ USB Solvent Recycler (SmartSaverPlus), with PTFE Valve Body Material, with accessories
Product Number: KIT-460010-PTFE
Specifications:
Input Range: | ± 1000 mVolts |
Threshold: | 1 - 1000 mVolts (detects both positive and negative peaks) |
Delay: | 0 – 255 second |
Autozero: | 50% of input range |
Valve: | 3 way electrically actuated, ¼ - 28” flat bottom fittings, 30 psi max |
Wetted Materials: | PEEK (valve body) / PTFE (valve membrane, tubing) |
Inputs: | analog TTL (contact closure) user configurable |
Indicators: | ready (yellow) LED, recycle (green) LED |
PC Communication: | USB |
Power Requirements | 5 V/100mA (USB powered) |
Available in the Following Configurations:
The Biotech SmartSaver™ USB Solvent Recycler is a computer-controlled device that is connected via USB cable to a personal computer running an installed software application. The USB cable also provides the power required for the Biotech SmartSaver™ USB Solvent Recycler.
SmartSaver™ USB Solvent Recycler is a device dedicated for use in isocratic HPLC. Efficient recycling of mobile phase may save up to 90% of solvent. Usually, most of the mobile phase is free of contaminants and must not be wasted. With continuous monitoring of the detector signal solvent recycler performs redirection of the uncontaminated mobile phase back to the solvent reservoir and save the solvent and waste disposal costs.
According to input signal level the 3-way valve is switched to waste or recycle position. The switching valve is connected to the detector mobile phase output. If the signal level is greater than signal threshold, the valve is switched to waste position. The back switching to recycle position is delayed with respect to time required to liquid transport from the detector cell to 3-way valve.
USB Solvent Recycler is a device dedicated for use in isocratic HPLC. Efficient recycling of mobile phase may save up to 90% of solvent. Usually, most of the mobile phase is free of contaminants and must not be wasted. With continuous monitoring of the detector signal solvent recycler performs redirection of the uncontaminated mobile phase back to the solvent reservoir and save the solvent and waste disposal costs.
According to input signal level the 3-way valve is switched to waste or recycle position. The switching valve is connected to the detector mobile phase output. If the signal level is greater than signal threshold, the valve is switched to waste position. The back switching to recycle position is delayed with respect to time required to liquid transport from the detector cell to 3-way valve
- Model: KIT-460010-PTFE
- Manufactured by: Biotech