ATEX RV3 230V, 1-ph, 50Hz Ex II 2G IIB T4
Overview
The RV3 pump has an external ATEX classification of II 2G IIC T4 and is suitable for use in potentially explosive atmospheres.
ATEX pumps with flameproof motors require the user to provide 2 off hazardous area cable glands and cables. In addition, connection of the thermistors to an appropriate safety circuit must be made to switch off the pump if overheating occurs.
ATEX pumps with flameproof motors require the user to provide 2 off hazardous area cable glands and cables. In addition, connection of the thermistors to an appropriate safety circuit must be made to switch off the pump if overheating occurs.
Technology
All our RV pumps are significantly quieter – noise levels of 48 dBA 50Hz are typically half the noise of a conventional pump and have been achieved by extensive work on the drive train and motor.
The pumps have the unique ability to deliver excellent ultimate vacuum in both high vacuum and high throughput modes with or without gas ballast. This gives the user an unrivalled opportunity to select the optimum pumping performance without compromising the application.
The simple to use mode selector and accessible, three-position gas ballast control allow the pump to be reconfigured at any time, even when the pump is running.
Applications
- Hazardous area pumping
Technical Data
Displacement | |
50 Hz operation | 3.7 m3h-1 / 2.2 ft3min-1 |
Speed (Pneurop 6602) | |
50 Hz operation | 3.3 m3h-1 / 2 ft3min-1 |
Ultimate Pressure (Total) | |
High vacuum mode | 2 x 10-3 mbar / 1.5 x 10-3 Torr |
High Throughput mode | 3 x 10-2 mbar / 2.3 x 10-2 Torr |
Ultimate Pressure – GB I (Total) | |
High vacuum mode | 3 x 10-2 mbar / 2.3 x 10-2 Torr |
High throughput mode | 6 x 10-2 mbar / 4.6 x 10-2 Torr |
Ultimate Pressure – GB II (Total) | |
High throughput mode | 1.2 x 10-1 mbar / 9.1 x 10-2 Torr |
Inlet connection | NW25 |
Outlet connection | NW25 |
Maximum allowed outlet pressure | 1 bar gauge / 14 psig |
Maximum allowed inlet and gas ballast pressure | 0.5 bar gauge / 7 psig |
Maximum water vapor inlet pressure | 80 mbar / 60 Torr |
Maximum water vapor pumping rate | |
Gas ballast low flow | 60 g h-1 |
Gas ballast high flow | 220 g h-1 |
Motor power | |
50Hz | 250 W |
Electrical supply | |
1-phase 50 Hz | 230 V, |
Operating temperature range | 12 - 40 ºC |
Weight, without oil | 21.5 kg / 43 lbs |
Noise | 48 dBA @ 50 Hz |
Oil capacity | |
Maximum | 0.7 liter |
Minimum | 0.42 liter |
Recommended oil (supplied) | Ultragrade 19 |
- Model: A65218991