Inertsil ODS-3
GL Sciences Inertsil ODS-3 Capillary EX-Nano Column, 100 Å, 3 µm, 0.7 x 50 mm
Product Number: 5020-11705
First analysis with ultra high inertness and high durability
Inertsil columns were developed by GL Sciences in 1986 for sample separations using high-performance liquid chromatography. Starting with Inertsil ODS, a new type of bonded silica was produced providing unmatched performance and reproducibility. Further refinements of evolved silica and the introduction of new phases have allowed Inertsil to achieve industry leading performance for analyte separation to become one of the most highly used columns for HPLC.
Inertsil ODS-3 is still GL Sciences’ most popular phase and continues to be used world widely and reliably for long established methods in pharmaceutical, and contract research labs. Inertsil ODS-3 has a relatively strong retentivity compared to commercially available ODS columns. In addition, the introduction of higher surface area silica provide high preparative loading capacity without sacrificing peak shape.
Capillary HPLC Columns
Capillary EX and Capillary EX-Nano HPLC columns analyze trace amounts of samples in proteomic and bioanalytical analyses with high sensitivity and high resolution. Capillary EX and Capillary EX-Nano columns are totally porous particle-type columns with flow rates generally below 100 μL/min.
- Another capillary column called MonoCap uses monolithic silica technology to provide high throughput, high sensitivity, and high resolution separation of peptides and protein digests.
- MonoCap Fast-Flow provides a high throughput analysis at half the operating pressures of totally porous particle-type columns. In MonoCap
- Nano-flow, the sizes of the mesopores and throughpores are optimized for extremely high LC/MS sensitivity.
- MonoCap Trap columns are also available for on-line preconcentration or desalting of protein and peptide samples prior to HPLC separation with mass spectrometry detection.
Particle Type Capillary HPLC Columns
Columns with I.D.s of 0.05, 0.075, 0.1 and 0.2 mm are Capillary EX-Nano columns. Those with I.D.s of 0.3, 0.5 and 0.7 mm are Capillary EX columns. Capillary EX-Nano columns intrcduce a fused silica capillary tube with a very smooth and clean inner surface providing a high number of theoretical plates. Capillary EX columns employ the column hardware used in analytical columns, which is very easy to use.
Specifications:
Description | Inertsil ODS-3 3µm CapillaryEx-Nano column 0.7 x 50mm |
---|---|
Quantity | 1 Stk |
Manufacturer | GL Sciences |
Brand | Inertsil |
Product Type | HPLC Column |
Base Material | 3 Series High Purity Silica Gel |
Length | 50 mm |
Internal Diameter | 0.7 mm |
Particle Size | 3 µm |
Chemistry | C18 (RP-18, ODS, Octadecyl) |
Chemistry Producers Term | ODS-3 |
Pore Size | 100 Å (10 nm) |
Pore volume | 1.05 mL/g |
Max Operating Pressure | 15 MPa(150 bar) |
USP Class | L1 |
Carbon Load | 15.0 % |
Bet Surface Area | 450 m2/g |
Endcapping | endcapped |
Column Type | Capillary Column |
Hardware Material | Stainless Steel |
Hardware Type | Ready-to-use Column |
pH Minimum | 2.0 |
pH Maximum | 7.5 |
Mode of Separation | Reversed Phase Chromatography (RP) |
Technology | HPLC |
Matrix | Silica |
Particle Morphology | spherical, fully porous |
- Model: 5020-11705
- Manufactured by: GL Sciences