Welcome, Sign In First time visitor? Create a New Account
Your cart is empty

Imtakt Cadenza CX-C18

High steric selectivity and molecular recognition C18 column for general use, ideal for separation of isomers and other difficult to separate compounds.

Brand new polar end-capping technology provides a more complete coverage of surface silanols and unique selectivity.

Conventional ODS columns, including hybrid-silica type columns, require extensive end-capping in order to decrease residual silanols, which may negatively affect peak shape for basic compounds. Traditionally, this end-capping process has used methyl silane compounds which have a mild hydrophobic interaction. Viewing this interaction in terms of reversed-phase mode, the surface of the stationary phase presents two very different kinds of hydrophobic structures, octadecyl ligands(C18) and the methyl end-capping. These different hydrophobicities may provide an inconsistent response against a solutes interaction with the stationary phase, resulting in poor peak shape and reduced plate counts. Instead of relying on traditional end-capping with trimethyl silane (TMS) compounds, we have succeeded to develop a revolutionary surface modification technology using alcohol structures, which has been adapted to our brand new Cadenza CX-C18. This means that electrostatic interaction from the polar end-capped surface and hydrophobic interaction from the C18 ligand will localize the polarity of the surface and increase the recognition power of a complex compounds hydrophobic/hydrophilic structure. Therefore, Cadenza CX-C18 will have an alternative selectivity for certain compounds and possibly improved peak shape compared to conventional end-capped ODS columns.

  • Our first column featuring modified alcohol polar end-capping
  • Nearly 100% coverage of active surface silanol sites
  • Reduces tailing for basic compounds in acidic conditions
  • Alternative selectivity from traditional C18 columns
  • High steric selectivity and molecular recognition
  • Ideal for difficult isomer or impurity separations


Item Name Product Image Price

Imtakt Cadenza CX-C18 HT 3mm ID, 75mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX033T

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 HT Polar End-Capping 75mm x 3mm, 3μm, 120Å, Analytical HPLC Column, Pressure limits of up to: 50M Pa, 500 bar, 7,500 psi Imtakt Product Number...
Imtakt Cadenza CX-C18 HT 3mm ID, 75mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX033T £308.00Buy Now

Imtakt Cadenza CX-C18 HT 3mm ID, 100mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX034T

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 HT Polar End-Capping 100mm x 3mm, 3μm, 120Å, Analytical HPLC Column, Pressure limits of up to: 50M Pa, 500 bar, 7,500 psi Imtakt Product...
Imtakt Cadenza CX-C18 HT 3mm ID, 100mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX034T £340.00Buy Now

Imtakt Cadenza CX-C18 HT 3mm ID, 150mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX035T

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 HT Polar End-Capping 150mm x 3mm, 3μm, 120Å, Analytical HPLC Column, Pressure limits of up to: 50M Pa, 500 bar, 7,500 psi Imtakt Product...
Imtakt Cadenza CX-C18 HT 3mm ID, 150mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX035T £372.00Buy Now

Imtakt Cadenza CX-C18 HT 3mm ID, 250mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX036T

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 HT Polar End-Capping 250mm x 3mm, 3μm, 120Å, Analytical HPLC Column, Pressure limits of up to: 50M Pa, 500 bar, 7,500 psi Imtakt Product...
Imtakt Cadenza CX-C18 HT 3mm ID, 250mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX036T £480.00Buy Now

Imtakt Cadenza CX-C18 HT 4.6mm ID, 10mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX000T

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 Polar HT End-Capping 10mm x 4.6mm, 3μm, 120Å, Analytical HPLC Column, Pressure limits of up to: 50M Pa, 500 bar, 7,500 psi Imtakt Product...
Imtakt Cadenza CX-C18 HT 4.6mm ID, 10mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX000T £288.00Buy Now

Imtakt Cadenza CX-C18 HT 4.6mm ID, 20mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX009T

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 HT Polar End-Capping 20mm x 4.6mm, 3μm, 120Å, Analytical HPLC Column, Pressure limits of up to: 50M Pa, 500 bar, 7,500 psi Imtakt Product...
Imtakt Cadenza CX-C18 HT 4.6mm ID, 20mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX009T £288.00Buy Now

Imtakt Cadenza CX-C18 HT 4.6mm ID, 30mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX001T

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 HT Polar End-Capping 30mm x 4.6mm, 3μm, 120Å, Analytical HPLC Column, Pressure limits of up to: 50M Pa, 500 bar, 7,500 psi Imtakt Product...
Imtakt Cadenza CX-C18 HT 4.6mm ID, 30mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX001T £288.00Buy Now

Imtakt Cadenza CX-C18 HT 4.6mm ID, 50mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX002T

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 HT Polar End-Capping 50mm x 4.6mm, 3μm, 120Å, Analytical HPLC Column, Pressure limits of up to: 50M Pa, 500 bar, 7,500 psi Imtakt Product Number...
Imtakt Cadenza CX-C18 HT 4.6mm ID, 50mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX002T £288.00Buy Now

Imtakt Cadenza CX-C18 HT 4.6mm ID, 75mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX003T

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 HT Polar End-Capping 75mm x 4.6mm, 3μm, 120Å, Analytical HPLC Column, Pressure limits of up to: 50M Pa, 500 bar, 7,500 psi Imtakt Product...
Imtakt Cadenza CX-C18 HT 4.6mm ID, 75mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX003T £308.00Buy Now

Imtakt Cadenza CX-C18 HT 4.6mm ID, 100mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX004T

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 HT Polar End-Capping 100mm x 4.6mm, 3μm, 120Å, Analytical HPLC Column, Pressure limits of up to: 50M Pa, 500 bar, 7,500 psi Imtakt Product...
Imtakt Cadenza CX-C18 HT 4.6mm ID, 100mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX004T £340.00Buy Now

Imtakt Cadenza CX-C18 HT 4.6mm ID, 150mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX005T

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 HT Polar End-Capping 150mm x 4.6mm, 3μm, 120Å, Analytical HPLC Column, Pressure limits of up to: 50M Pa, 500 bar, 7,500 psi Imtakt Product...
Imtakt Cadenza CX-C18 HT 4.6mm ID, 150mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX005T £372.00Buy Now

Imtakt Cadenza CX-C18 HT 4.6mm ID, 250mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX006T

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 HT Polar End-Capping 250mm x 4.6mm, 3μm, 120Å, Analytical HPLC Column, Pressure limits of up to: 50M Pa, 500 bar, 7,500 psi Imtakt Product...
Imtakt Cadenza CX-C18 HT 4.6mm ID, 250mm Length, 3um,ODS, Polar End-Capping, 50MPa - CX006T £480.00Buy Now

Imtakt Cadenza CX-C18 UP 2mm ID, 30mm Length, 3um,ODS, Polar End-Capping,100MPa - CX021U

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 UP Polar End-Capping 30mm x 2mm, 3μm, 120Å, Analytical UHPLC Column, Pressure limits of up to: 10M Pa, 1000 bar, 15,000 psi Imtakt Product Number...
Imtakt Cadenza CX-C18 UP 2mm ID, 30mm Length, 3um,ODS, Polar End-Capping,100MPa - CX021U £288.00Buy Now

Imtakt Cadenza CX-C18 UP 2mm ID, 50mm Length, 3um,ODS, Polar End-Capping,100MPa - CX022U

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 UP Polar End-Capping 50mm x 2mm, 3μm, 120Å, Analytical UHPLC Column, Pressure limits of up to: 10M Pa, 1000 bar, 15,000 psi Imtakt Product Number...
Imtakt Cadenza CX-C18 UP 2mm ID, 50mm Length, 3um,ODS, Polar End-Capping,100MPa - CX022U £320.00Buy Now

Imtakt Cadenza CX-C18 UP 2mm ID, 75mm Length, 3um,ODS, Polar End-Capping,100MPa - CX023U

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 UP Polar End-Capping 75mm x 2mm, 3μm, 120Å, Analytical UHPLC Column, Pressure limits of up to: 10M Pa, 1000 bar, 15,000 psi Imtakt Product Number...
Imtakt Cadenza CX-C18 UP 2mm ID, 75mm Length, 3um,ODS, Polar End-Capping,100MPa - CX023U £352.00Buy Now

Imtakt Cadenza CX-C18 UP 2mm ID, 100mm Length, 3um,ODS, Polar End-Capping,100MPa - CX024U

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 UP Polar End-Capping 100mm x 2mm, 3μm, 120Å, Analytical UHPLC Column, Pressure limits of up to: 10M Pa, 1000 bar, 15,000 psi Imtakt Product Number...
Imtakt Cadenza CX-C18 UP 2mm ID, 100mm Length, 3um,ODS, Polar End-Capping,100MPa - CX024U £384.00Buy Now

Imtakt Cadenza CX-C18 UP 2mm ID, 150mm Length, 3um,ODS, Polar End-Capping,100MPa - CX025U

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 UP Polar End-Capping 150mm x 2mm, 3μm, 120Å, Analytical UHPLC Column, Pressure limits of up to: 10M Pa, 1000 bar, 15,000 psi Imtakt Product Number...
Imtakt Cadenza CX-C18 UP 2mm ID, 150mm Length, 3um,ODS, Polar End-Capping,100MPa - CX025U £480.00Buy Now

Imtakt Cadenza CX-C18 UP 2mm ID, 250mm Length, 3um,ODS, Polar End-Capping,100MPa - CX026U

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 UP Polar End-Capping 250mm x 2mm, 3μm, 120Å, Analytical UHPLC Column, Pressure limits of up to: 10M Pa, 1000 bar, 15,000 psi Imtakt Product Number...
Imtakt Cadenza CX-C18 UP 2mm ID, 250mm Length, 3um,ODS, Polar End-Capping,100MPa - CX026U £608.00Buy Now

Imtakt Cadenza CX-C18 MF 2mm ID, 30mm Length, 3um,ODS, Polar End-Capping, Metal-Free Column - CX021F

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 MF Polar End-Capping 30mm x 2mm, 3μm, 120Å, Metal-Free HPLC Column, Pressure limits of up to: 50MPa, 500bar, 7,500psi Imtakt Product Number  ...
Imtakt Cadenza CX-C18 MF 2mm ID, 30mm Length, 3um,ODS, Polar End-Capping, Metal-Free Column - CX021F £384.00Buy Now

Imtakt Cadenza CX-C18 MF 2mm ID, 50mm Length, 3um,ODS, Polar End-Capping, Metal-Free Column - CX022F

Cadenza CX-C18  Polar End-Capping ODS Column Cadenza CX-C18 MF Polar End-Capping 50mm x 2mm, 3μm, 120Å, Metal-Free HPLC Column, Pressure limits of up to: 50MPa, 500bar, 7,500psi Imtakt Product...
Imtakt Cadenza CX-C18 MF 2mm ID, 50mm Length, 3um,ODS, Polar End-Capping, Metal-Free Column - CX022F £384.00Buy Now