Welcome, Sign In First time visitor? Create a New Account
Your cart is empty

Imtakt Cadenza HS-C18

World’s first reproducible direct injection column.

The Cadenza family of columns is a high quality series of ODS columns with a ligand density optimized for steric selectivity. These powerful columns are able to distinguish subtle differences in your analytes making it an excellent choice for isomer separation, or detection of impurities. These columns have low back pressure due to the high quality of materials used in their manufacturing. With a unique polymeric end-capping these columns will also provide very little unwanted secondary interactions and better peak shape.

  • World’s first reproducible direct injection column
  • High efficiency 3µ ODS column with low back-pressure
  • Proprietary phase designed to elute compounds larger than 30kDa while retaining small molecules
  • Ideal for use with biological samples like blood, urine, plasma, serum or cell culture extracts
  • No need for complicated sample preparation, just dilute and shoot


Item Name Product Image Price

Imtakt Guard Cartridge HS-C18 1mm ID, 5mm Length, 3um,Hybrid ODS,end-capped (5x1mm), 3pcs - GCHS0C

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3μm 5mm x 1.0mm (Hybrid ODS end-capped) Guard Cartridge, Pack of 3 Imtakt Product Number   GCHS0C Column Specifications: Base Material: Silica...
Imtakt Guard Cartridge HS-C18 1mm ID, 5mm Length, 3um,Hybrid ODS,end-capped (5x1mm), 3pcs - GCHS0C £181.22Buy Now

Imtakt Guard Cartridge HS-C18 2mm ID, 5mm Length, 3um,Hybrid ODS,end-capped (5x2mm), 3pcs - GCHS0S

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3μm 5mm x 2mm (Hybrid ODS end-capped) Guard Cartridge, Pack of 3 Imtakt Product Number   GCHS0S Column Specifications: Base Material: ...
Imtakt Guard Cartridge HS-C18 2mm ID, 5mm Length, 3um,Hybrid ODS,end-capped (5x2mm), 3pcs - GCHS0S £133.94Buy Now

Imtakt Guard Cartridge HS-C18 8mm ID, 10mm Length, 3um,Hybrid ODS,end-capped (10x8mm), 2pcs - GCHS0M

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3μm 10mm x 8mm (Hybrid ODS end-capped) Guard Cartridge, Pack of 2 Imtakt Product Number   GCHS0M Column Specifications: Base...
Imtakt Guard Cartridge HS-C18 8mm ID, 10mm Length, 3um,Hybrid ODS,end-capped (10x8mm), 2pcs - GCHS0M £181.22Buy Now

Imtakt Guard Holder for 1-6mmI.D. separation columns - GCH01S

Imtakt Guard Holder for 1-6mm I.D. separation columns Quantity: 1 pc Particle morphology: spherical, porous Additional Imtakt Columns Available Imtakt Scherzo Imtakt Intrada Imtakt Cadenza Imtakt Presto Imtakt Unison ...
Imtakt Guard Holder for 1-6mmI.D. separation columns - GCH01S £204.86Buy Now

Imtakt Guard Holder for 10-20mm column, enclosed an U-Shape column coupler - GCH12M

Guard Holder Guard Holder for 10-20mm column, enclosed an U-Shape column coupler xmm LxID Quantity: 1 pc Particle morphology: spherical, porous Additional Imtakt Columns Available Imtakt Scherzo Imtakt Intrada Imtakt Cadenza Imtakt...
Imtakt Guard Holder for 10-20mm column, enclosed an U-Shape column coupler - GCH12M £275.77Buy Now

Imtakt Guard Holder for 10-20mmI.D. separation columns - GCH02M

Guard Holder for 10-20 mm I.D. separation columns Quantity: 1 piece Particle morphology: spherical, porous Additional Imtakt Columns Available Imtakt Scherzo Imtakt Intrada Imtakt Cadenza Imtakt Presto Imtakt Unison Imtakt DACAPO ...
Imtakt Guard Holder for 10-20mmI.D. separation columns - GCH02M £275.77Buy Now

Imtakt Guard Holder for 4.6mm column, enclosed an U-Shape column coupler - GCH11S

Imtakt Guard Holder for 4.6mm column, enclosed an U-Shape column coupler xmm L x ID Quantity: 1 piece Particle morphology: spherical, porous Additional Imtakt Columns Available Imtakt Scherzo Imtakt Intrada Imtakt Cadenza Imtakt...
Imtakt Guard Holder for 4.6mm column, enclosed an U-Shape column coupler - GCH11S £204.86Buy Now

Imtakt Cadenza HS-C18 1mm ID, 30mm Length, 3um,Hybrid ODS,end-capped - HS011

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3µm 30mm x 1mm, 120Å (ODS Hybrid end-capped) HPLC Analytical Column, Pressure limits of up to : 20MPa, 250 bar, 3,000 psi ...
Imtakt Cadenza HS-C18 1mm ID, 30mm Length, 3um,Hybrid ODS,end-capped - HS011 £330.93Buy Now

Imtakt Cadenza HS-C18 1mm ID, 50mm Length, 3um,Hybrid ODS,end-capped - HS012

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3µm 50mm x 1mm, 120Å (ODS Hybrid end-capped) HPLC Analytical Column, Pressure limits of up to : 20MPa, 250 bar, 3,000 psi ...
Imtakt Cadenza HS-C18 1mm ID, 50mm Length, 3um,Hybrid ODS,end-capped - HS012 £354.56Buy Now

Imtakt Cadenza HS-C18 1mm ID, 75mm Length, 3um,Hybrid ODS,end-capped - HS013

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3µm 75mm x 1mm, 120Å (ODS Hybrid end-capped) HPLC Analytical Column, Pressure limits of up to : 20MPa, 250 bar, 3,000 psi ...
Imtakt Cadenza HS-C18 1mm ID, 75mm Length, 3um,Hybrid ODS,end-capped - HS013 £378.20Buy Now

Imtakt Cadenza HS-C18 1mm ID, 100mm Length, 3um,Hybrid ODS,end-capped - HS014

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3µm 100mm x 1mm, 120Å (ODS Hybrid end-capped) HPLC Analytical Column, Pressure limits of up to : 20MPa, 250 bar, 3,000 psi ...
Imtakt Cadenza HS-C18 1mm ID, 100mm Length, 3um,Hybrid ODS,end-capped - HS014 £417.60Buy Now

Imtakt Cadenza HS-C18 1mm ID, 150mm Length, 3um,Hybrid ODS,end-capped - HS015

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3µm 30mm x 150mm, 120Å (ODS Hybrid end-capped) HPLC Analytical Column, Pressure limits of up to : 20MPa, 250 bar, 3,000 psi ...
Imtakt Cadenza HS-C18 1mm ID, 150mm Length, 3um,Hybrid ODS,end-capped - HS015 £457.00Buy Now

Imtakt Cadenza HS-C18 1mm ID, 250mm Length, 3um,Hybrid ODS,end-capped - HS016

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3µm 250mm x 1mm, 120Å (ODS Hybrid end-capped) HPLC Analytical Column, Pressure limits of up to : 20MPa, 250 bar, 3,000 psi ...
Imtakt Cadenza HS-C18 1mm ID, 250mm Length, 3um,Hybrid ODS,end-capped - HS016 £590.94Buy Now

Imtakt Cadenza HS-C18 1.5mm ID, 30mm Length, 3um,Hybrid ODS,end-capped - HS071

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3µm 30mm x 1.5mm, 120Å (ODS Hybrid end-capped) HPLC Analytical Column, Pressure limits of up to : 20MPa, 250 bar, 3,000 psi ...
Imtakt Cadenza HS-C18 1.5mm ID, 30mm Length, 3um,Hybrid ODS,end-capped - HS071 £299.41Buy Now

Imtakt Cadenza HS-C18 1.5mm ID, 50mm Length, 3um,Hybrid ODS,end-capped - HS072

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3µm 50mm x 1.5mm, 120Å (ODS Hybrid end-capped) HPLC Analytical Column, Pressure limits of up to : 20MPa, 250 bar, 3,000 psi ...
Imtakt Cadenza HS-C18 1.5mm ID, 50mm Length, 3um,Hybrid ODS,end-capped - HS072 £330.93Buy Now

Imtakt Cadenza HS-C18 1.5mm ID, 75mm Length, 3um,Hybrid ODS,end-capped - HS073

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3µm 75mm x 1.5mm, 120Å (ODS Hybrid end-capped) HPLC Analytical Column, Pressure limits of up to : 20MPa, 250 bar, 3,000 psi ...
Imtakt Cadenza HS-C18 1.5mm ID, 75mm Length, 3um,Hybrid ODS,end-capped - HS073 £354.56Buy Now

Imtakt Cadenza HS-C18 1.5mm ID, 100mm Length, 3um,Hybrid ODS,end-capped - HS074

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3µm 100mm x 1.5mm, 120Å (ODS Hybrid end-capped) HPLC Analytical Column, Pressure limits of up to : 20MPa, 250 bar, 3,000 psi ...
Imtakt Cadenza HS-C18 1.5mm ID, 100mm Length, 3um,Hybrid ODS,end-capped - HS074 £378.20Buy Now

Imtakt Cadenza HS-C18 1.5mm ID, 150mm Length, 3um,Hybrid ODS,end-capped - HS075

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3µm 150mm x 1.5mm, 120Å (ODS Hybrid end-capped) HPLC Analytical Column, Pressure limits of up to : 20MPa, 250 bar, 3,000 psi ...
Imtakt Cadenza HS-C18 1.5mm ID, 150mm Length, 3um,Hybrid ODS,end-capped - HS075 £417.60Buy Now

Imtakt Cadenza HS-C18 1.5mm ID, 250mm Length, 3um,Hybrid ODS,end-capped - HS076

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3µm 250mm x 1.5mm, 120Å (ODS Hybrid end-capped) HPLC Analytical Column, Pressure limits of up to : 20MPa, 250 bar, 3,000 psi ...
Imtakt Cadenza HS-C18 1.5mm ID, 250mm Length, 3um,Hybrid ODS,end-capped - HS076 £535.78Buy Now

Imtakt Cadenza HS-C18 2mm ID, 10mm Length, 3um,Hybrid ODS,end-capped - HS020

Cadenza HS-C18  hybrid reproducible direct injection column Cadenza HS-C18 3µm 10mm x 2mm, 120Å (ODS Hybrid end-capped) HPLC Analytical Column, Pressure limits of up to : 20MPa, 250 bar, 3,000 psi ...