Item Name |
Product Image |
Price |
SOLUTION-NEXION 2200 DL STD/DRC STANDARD |
![PerkinElmer SOLUTION-NEXION 2200 DL STD/DRC STANDARD - N8171046 PerkinElmer SOLUTION-NEXION 2200 DL STD/DRC STANDARD - N8171046](bmz_cache/3/31e504797d833aa658980b5057f71b78.image.110x55.jpg) |
... more info
|
Multi-Element Standard Vol 2% HNO3 /per 500 mL. Catalog error: This standard also includes Lithium. 2% HNO3/500 mL 1 µg/mL Barium, Magnesium, 10 µg/mL of Lanthanum, Lithium, Manganese, Nickel, Strontium, Zinc 50 µg/mL of Arsenic, Potassium. |
![PerkinElmer Multi-Element Standard Vol 2% HNO3 /per 500 mL - N0691579 PerkinElmer Multi-Element Standard Vol 2% HNO3 /per 500 mL - N0691579](bmz_cache/e/eac296cb4b2ead6d0a4a0ab6f49aa20c.image.110x110.jpg) |
... more info
|
Multi-element Mixed Standard Solution I, Matrix per Vol. 2% HNO3 per 100mL. Multi-element Mixed Standard Solution I, Matrix per Vol. 2% HNO3 per 100mL, Concentration of Element: 50µg/mL Beryllium, 150µg/mL Cadmium, 500µg/mL Lead, 100µg/mL... |
![PerkinElmer Multi-element Mixed Standard Solution I, Matrix per Vol. 2% HNO3 per 100mL - N9300200 PerkinElmer Multi-element Mixed Standard Solution I, Matrix per Vol. 2% HNO3 per 100mL - N9300200](bmz_cache/0/084232fd8b16049895c011e40b439936.image.110x110.jpg) |
... more info
|
Multi-element Mixed Standard Solution II, Matrix per Vol. 5% HNO3 per 100mL. Multi-element Mixed Standard Solution II, Matrix per Vol. 5% HNO3 per 100mL, Concentration of Element: 100µg/mL Barium, 100µg/mL Cobalt, 100µg/mL Copper, 10,000µg/mL... |
![PerkinElmer Multi-element Mixed Standard Solution II, Matrix per Vol. 5% HNO3 per 100mL - N9300201 PerkinElmer Multi-element Mixed Standard Solution II, Matrix per Vol. 5% HNO3 per 100mL - N9300201](bmz_cache/0/084232fd8b16049895c011e40b439936.image.110x110.jpg) |
... more info
|
Multi-element Mixed Standard Solution III, Matrix per Vol. 2% HNO3 per 100mL. Multi-element Mixed Standard Solution III, Matrix per Vol. 2% HNO3 per 100mL, Concentration of Element: 500µg/mL Arsenic, 100µg/mL Silicon, 100µg/mL Molybdenum. |
![PerkinElmer Multi-element Mixed Standard Solution III, Matrix per Vol. 2% HNO3 per 100mL - N9300202 PerkinElmer Multi-element Mixed Standard Solution III, Matrix per Vol. 2% HNO3 per 100mL - N9300202](bmz_cache/0/084232fd8b16049895c011e40b439936.image.110x110.jpg) |
... more info
|
Multi-element Mixed Standard Solution IV, Matrix per Vol. 5% HNO3 per 100mL. Multi-element Mixed Standard Solution IV, Matrix per Vol. 5% HNO3 per 100mL, Concentration of Element: 200µg/mL Aluminium, 1,000µg/mL Calcium, 20µg/mL Chromium, 20µg/mL... |
![PerkinElmer Multi-element Mixed Standard Solution IV, Matrix per Vol. 5% HNO3 per 100mL - N9300203 PerkinElmer Multi-element Mixed Standard Solution IV, Matrix per Vol. 5% HNO3 per 100mL - N9300203](bmz_cache/0/084232fd8b16049895c011e40b439936.image.110x110.jpg) |
... more info
|
Multi-element Mixed Standard Solution V, Matrix per Vol. 5% HNO3 per 100mL. Multi-element Mixed Standard Solution V, Matrix per Vol. 5% HNO3 per 100mL, Concentration of Element: 200µg/mL Antimony, 100µg/mL Boron, 1,000µg/mL Magnesium, 50µg/mL... |
![PerkinElmer Multi-element Mixed Standard Solution V, Matrix per Vol. 5% HNO3 per 100mL - N9300204 PerkinElmer Multi-element Mixed Standard Solution V, Matrix per Vol. 5% HNO3 per 100mL - N9300204](bmz_cache/0/084232fd8b16049895c011e40b439936.image.110x110.jpg) |
... more info
|
Interference Check Standard, 5 Elements, Matrix per Vol. 5% HNO3 per 100mL. Interference Check Standard, 5 Elements, Matrix per Vol. 5% HNO3 per 100mL, Concentration of Element: 1200µg/mL Aluminium, 3000µg/mL Magnesium, 6000µg/mL Calcium. |
![PerkinElmer Interference Check Standard, 5 Elements, Matrix per Vol. 5% HNO3 per 100mL - N9300208 PerkinElmer Interference Check Standard, 5 Elements, Matrix per Vol. 5% HNO3 per 100mL - N9300208](bmz_cache/3/31e504797d833aa658980b5057f71b78.image.110x55.jpg) |
... more info
|
Spike Sample (ICP), Matrix per Volume 5% HNO3 per 100mL. Used to check the effect of sample matrix and methodology on spike recovery. Add 1.0mL of Spike Sample to your aqueous samples and add 2.0mL of Spike Sample to your solid samples prior to... |
![PerkinElmer Spike Sample (ICP), Matrix per Volume 5% HNO3 per 100mL - N9300230 PerkinElmer Spike Sample (ICP), Matrix per Volume 5% HNO3 per 100mL - N9300230](bmz_cache/0/084232fd8b16049895c011e40b439936.image.110x110.jpg) |
... more info
|
Instrument Calibration Standard 2: 125mL. Matrix per Volume: 5% HNO3/tr Tartaric Acid/tr HF per 100mL Contents: 100µg/mL: Ag, Al, As, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, Pb, Sb, Se, Sn, Sr, Ti, Tl, V, Zn. |
![PerkinElmer Instrument Calibration Standard 2: 125mL - N9301721 PerkinElmer Instrument Calibration Standard 2: 125mL - N9301721](bmz_cache/3/31e504797d833aa658980b5057f71b78.image.110x55.jpg) |
... more info
|
Silver (Ag) Pure Standard, 1,000 µg/mL, 2% HNO3, 125 mL Product Number: N9303816 For Inductively Coupled Plasma (ICP) Each Single Element Calibration Standard for AA and ICP-OES is supplied with a comprehensive Certificate of Analysis that... |
![PerkinElmer Silver (Ag) Pure Standard, 1,000 µg/mL, 2% HNO3, 125 mL - N9303816 PerkinElmer Silver (Ag) Pure Standard, 1,000 µg/mL, 2% HNO3, 125 mL - N9303816](bmz_cache/5/5a88ec3b4d76c06db9ade856c59a0655.image.110x110.jpg) |
... more info
|
Instrument Calibration Standard 3. 1000 PPM FE, K, CA, NA, MG, in 5% HNO3, 100 ML. |
![PerkinElmer Instrument Calibration Standard 3 - N9303818 PerkinElmer Instrument Calibration Standard 3 - N9303818](bmz_cache/3/31e504797d833aa658980b5057f71b78.image.110x55.jpg) |
... more info
|
Internal Standard Mix 100mL. 10 PPM LI6, SC, GE, Y, IN, TB, BI, in 5-10% HNO3, 100 ML. |
![PerkinElmer Internal Standard Mix 100mL - N9303832 PerkinElmer Internal Standard Mix 100mL - N9303832](bmz_cache/3/31e504797d833aa658980b5057f71b78.image.110x55.jpg) |
... more info
|
Internal Standard Mix - 500mL. STD, INTERNAL STANDARD MIX, 10 PPM LI6, SC, GE, Y, IN, TB, BI, in 5-10% HNO3, 500 ML. |
![PerkinElmer Internal Standard Mix - 500mL - N9303833 PerkinElmer Internal Standard Mix - 500mL - N9303833](bmz_cache/3/31e504797d833aa658980b5057f71b78.image.110x55.jpg) |
... more info
|
Quality Control Standard 21. 100 PPM AS, BE, CA, CD, CO, CR, CU, FE, LI, MG, MN, MO, NI, PB, SB, SE, SR, TI, TL, V, ZN, in 5% HNO3/trace Tartaric Acid/trace HF, 100 ML. |
![PerkinElmer Quality Control Standard 21 - N9303837 PerkinElmer Quality Control Standard 21 - N9303837](bmz_cache/3/31e504797d833aa658980b5057f71b78.image.110x55.jpg) |
... more info
|
Spike Sample Standard 1 (water). 500 PPM FE; 250 PPM BA, ZN; 100 PPM CO, CR, CU, MN, NI, SB, V; 50 PPM AS, PB; 25 PPM AG, BE, CD, SE, TL, in 5% HNO3/trace Tartaric Acid/trace HF, 100 ML. |
![PerkinElmer Spike Sample Standard 1 (water) - N9303839 PerkinElmer Spike Sample Standard 1 (water) - N9303839](bmz_cache/0/084232fd8b16049895c011e40b439936.image.110x110.jpg) |
... more info
|
Spike Sample Standard 2 (soil). 250 PPM BA, CR, CU, ZN; 150 PPM V; 125 PPM NI; 100 PPM CO, PB, SB; 50 PPM AS, CD; 25 PPM AG, BE, SE, TL, in 5% HNO3/trace Tartaric Acid/trace HF, 100 ML. |
![PerkinElmer Spike Sample Standard 2 (soil) - N9303840 PerkinElmer Spike Sample Standard 2 (soil) - N9303840](bmz_cache/0/084232fd8b16049895c011e40b439936.image.110x110.jpg) |
... more info
|
Spike Sample Standard 3. 200 PPM AL, BA; 50 PPM CO, MN, NI, V, ZN, 25 PPM CU; 20 PPM CR; 10 PPM SB; 5 PPM BE, CD, AG, TL; 4 PPM AS; 2 PPM PB; 1 PPM SE, in 5% HNO3/trace Tartaric Acid/trace HF, 100 ML. |
![PerkinElmer Spike Sample Standard 3 - N9303841 PerkinElmer Spike Sample Standard 3 - N9303841](bmz_cache/0/084232fd8b16049895c011e40b439936.image.110x110.jpg) |
... more info
|
Universal Data Acquisition Standards Kit |
![PerkinElmer Universal Data Acquisition Standards Kit - N9306225 PerkinElmer Universal Data Acquisition Standards Kit - N9306225](bmz_cache/9/91955b90543edd1dc263e2e2ddf1ebd9.image.110x110.jpg) |
... more info
|
Calibration Standard Set for Method 6010. Each bottle contains: -5000 ug/mL Ca, K, Mg, Na in 5% HNO3/100 mL, -400 ug/mL Ni; 200 ug/mL Zn; 150 ug/mL Mn; 100 ug/mL Ag, Cr in 5% HNO3/100 mL, -2000 ug/mL Al, Ba; 1000 ug/mL Fe; 500 ug/mL Co, V; 250 ug/mL... |
![PerkinElmer Calibration Standard Set for Method 6010 - N9307104 PerkinElmer Calibration Standard Set for Method 6010 - N9307104](bmz_cache/f/fbc5d08e475e7c54bc359a153b7d0b2e.image.110x110.jpg) |
... more info
|