Manufacturers
Specials - [more]

CLEARANCE Waters Tubing Assembly, I-Class CM-A, High Pressure, 0.003 Stainless Steel, 14.5 inches - 700008869
£250.00 £102.50
Save: 59% off
Save: 59% off

CLEARANCE Waters SunFire C18 Column, 100A, 10 um, 4.6 mm X 150 mm, 1/pk - 186003390
£906.00 £364.51
Save: 60% off
Save: 60% off

CLEARANCE Waters Guard-Pak Holder - WAT088141
£612.00 £381.09
Save: 38% off
Save: 38% off

CLEARANCE Waters ACQUITY UPLC BEH Phenyl Method Validation Kit, 130A, 1.7 um, 2.1 mm X 50 mm, 3/pk - 186004050
£2,942.00 £1,166.98
Save: 60% off
Save: 60% off

CLEARANCE Waters XBridge BEH C18 Method Validation Kit, 130 A, 5 um, 4.6 mm ID x 150 mm Length, 3/pk - 186003775
£2,824.00 £1,161.42
Save: 59% off
Save: 59% off
New Products - [more]

CTC Syringe gastight 1ml, 1/pk
Live chat below or contact us for latest price.

CTC Syringe gastight 100 µl, 1/pk
Live chat below or contact us for latest price.

CTC Syringe for PAL DLW Option, 100 µl, 1/pk
Live chat below or contact us for latest price.
Home >
Chromatography Supplies >
Purospher HPLC Columns >
Purospher® STAR RP-18 Endcapped 150-3 Hibar® RT HPLC Column, 120 Å, 5 µm, 3 × 150 mm - 150617
Purospher® STAR RP-18 Endcapped Hibar®
Inner Diameter (I.D.): 3 mm
Length: 150 mm
Package Contents: 1 Column
Purospher® STAR RP-18 endcapped HPLC columns are designed for universal use. Basic, neutral, and metal chelating
compounds can easily be separated with simple mobile phases – naturally without peak tailing! Thanks to its
outstanding performance and stability, Purospher® STAR RP-18 endcapped offers maximum flexibility in method
development. Robust methods can be developed over the entire pH range from 1.5 to 10.5. The high pH-stability up
to pH 10.5 allows the separation of strongly basic compounds with alkaline eluents. The combination of high purity
silica, best all-round retention characteristics, outstanding pH stability up to pH 10.5, and suitability for up to 100%
aqueous mobile phases, make Purospher® STAR RP-18 endcapped an all-round top performance column, almost
universal in its range of applications.
The traditional heart of HPLC is the “ready-to-use” column with threads at both ends onto which reducers for capillary
connection are screwed. As a rule, precolumns are coupled with the main column via capillaries. If the column is
exhausted, the user has two possibilities: Refilling, provided aggressive eluents do not prevent this by causing corrosion
or worn threads, or the whole column is discarded. Column refilling without tube revision is problematic in view

