Shinwa DS-TG reagent kit
Product Number: SHINWADSTG
A kit that efficiently performs methyl esterification of triglycerides required for gas chromatograph analysis.
Features of Shinwa DS-TG
- This kit can be processed in a shorter time than the conventional method.
- It can be safely performed because it is processed below the boiling point of methanol (64.7 ° C).
- No heating equipment required.
- After the methylester reaction, the lower layer (water layer) is colored blue, making it easy to sample.
- One set can perform about 100 times of methyl esterification treatment.
Recommended reagent amount
- Solution A 1 mL
- Solution B [reaction solution] 50 μL
- Solution C [stop solution] 1 mL
- Under the above conditions, the sample can be processed up to 50 mg.
Target substance of Shinwa DS-TG
Triglycerides, diglycerides, monoglycerides, glycerophospholipids, glyceroglycolipids
* Cannot be used for free fatty acids, sterol esters, and sphingolipids.
Shinwa DS-TG kit contents
Product name / capacity | quantity | Laws and regulations |
Solution A 100 ml | 1 | Dangerous Goods Class 4 First Petroleum Danger Class II Water-insoluble liquid |
Solution B [reaction solution] 5 ml | 1 | Dangerous Goods Class 4 First Petroleum Danger Class II Water-Soluble Liquid |
Solution C [Stop solution] (blue) 100 ml | 1 | Not applicable |
Notes
- Solution B is alkaline.
- Shake Solution B well before use.
- When using, wear protective glasses, protective masks, protective gloves, etc., and be careful not to scatter reagents.
- The expiration date is 2 years from the date of manufacture.
Equipment to prepare
- Reaction vessel (eg glass test tube 12.5 mmID x 165 mmL)
- Pipettes
- Stirrer such as vortex mixer
- Vials (for storage of methyl esterified samples)
- Model: SHINWADSTG
- Manufactured by: Shinwa Chemical Industries Ltd