OHpak SB-800 / OHpak LB-800 columns separation by size for a variety of molecular weights
OHpak SB-807G HPLC Standard Guard Column - Aqueous high molecular weight analysis column - 35μm - 8.0mm I.D. x 50mm Length
Shodex Product Number: F6709431
The polymer-based SEC (GFC) column for modified proteins, PEGs, polysaccharides, surfactants
Specifications
Description |
OHpak SB-807G 50x8mm |
Chemistry Producers Term |
SB |
Mode of Separation |
Gel Filtration (GFC) / SEC Size Exclusion |
Plates per column |
(guard) |
Housing material |
steel |
Pore Size |
30,000 Å |
Salt Concentration |
≤ 0.5 M |
Temperature range |
4 to 60°C |
pH range |
3 to 10 |
Shipping solvent |
H2O |
MW range |
500,000 - (500,000,000) |
Exclusion limit |
(500,000,000) |
Internal Diameter |
8 mm |
Length |
50 mm |
Brand |
OHPAK |
Particle Size |
35 µm |
USP Class |
L38, L39 |
OHpak SB-800 HQ series Features
- Polymer-based packed columns for aqueous SEC (GFC) analysis
- Supports a wide range of molecular weight sample analysis
- The eluent can be replaced with DMF (except SB-802 HQ and SB-807 HQ), enabling the analysis of polar polymers
- For modified proteins, PEGs, polysaccharides, surfactants
OHpak SB-807 HQ Features
- Column for the analysis of water-soluble ultra high molecular weight polymers
- Large particle-size gel prevents shear degradation of polymers
- Fulfills USP L38 requirements - A methacrylate-based size-exclusion packing for water-soluble samples.
- Fulfills USP L39 requirements - A hydrophilic polyhydroxymethacrylate gel of totally porous spherical resin.
- Suitable for: Polysaccharides - SEC |
Possible Applications
- Calibration Curve for SB-807 HQ (Aqueous Eluent: Pullulan)
- Polyacrylamide (3) (Comparison with SB-807 HQ and SB-806 HQ)
- Hyaluronic Acid (4) (SB-807 HQ)
- Polyacrylamide (3) (Comparison with SB-807 HQ and SB-806 HQ)
Range of Aqueous SEC (GFC) Columns: Polymer-based columns
Product Code |
Product Name |
Plate Number
(TP/column) |
Particle Size
(μm) |
Pore Size
(Å) |
Column Size (mm)
I.D. x Length |
Shipping Solvent |
Standard columns | Base Material: Polyhydroxymethacrylate | SB-806M HQ is a mixed-gel column capable of analyzing samples over a wide range of molecular weight distribution |
F6429100 |
OHpak SB-802 HQ |
≥ 12,000 |
8 |
100 |
8.0 x 300 |
0.02 % NaN3 aq. |
F6429101 |
OHpak SB-802.5 HQ |
≥ 16,000 |
6 |
200 |
8.0 x 300 |
0.02 % NaN3 aq. |
F6429102 |
OHpak SB-803 HQ |
≥ 16,000 |
6 |
800 |
8.0 x 300 |
0.02 % NaN3 aq. |
F6429103 |
OHpak SB-804 HQ |
≥ 16,000 |
10 |
2,000 |
8.0 x 300 |
0.02 % NaN3 aq. |
F6429104 |
OHpak SB-805 HQ |
≥ 12,000 |
13 |
7,000 |
8.0 x 300 |
0.02 % NaN3 aq. |
F6429105 |
OHpak SB-806 HQ |
≥ 12,000 |
13 |
15,000 |
8.0 x 300 |
0.02 % NaN3 aq. |
F6429106 |
OHpak SB-806M HQ |
≥ 12,000 |
13 |
15,000 |
8.0 x 300 |
0.02 % NaN3 aq. |
F6709430 |
OHpak SB-G 6B |
(guard column) |
10 |
- |
6.0 x 50 |
0.02 % NaN3 aq. |
Aqueous high molecular weight analysis column | Standard columns | Base Material: Polyhydroxymethacrylate |
F6429108 |
OHpak SB-807 HQ |
≥ 1,500 |
35 |
30,000 |
8.0 x 300 |
H2O |
F6709431 |
OHpak SB-807G |
(guard column) |
35 |
|
8.0 x 50 |
H2O |
Preparative columns [ Preparative columns are made to order. ] | Base Material: Polyhydroxymethacrylate |
Product Code |
Product Name |
Plate Number
(TP/column) |
Particle Size
(μm) |
Column Size (mm)
I.D. x Length |
Shipping Solvent |
Standard Column |
F6516011 |
OHpak SB-2002 |
≥ 9,000 |
15 |
20.0 x 300 |
0.02 % NaN3 aq. |
SB-802 HQ |
F6516012 |
OHpak SB-2002.5 |
≥ 12,000 |
10 |
20.0 x 300 |
0.02 % NaN3 aq. |
SB-802.5 HQ |
F6516013 |
OHpak SB-2003 |
≥ 12,000 |
10 |
20.0 x 300 |
0.02 % NaN3 aq. |
SB-803 HQ |
F6516014 |
OHpak SB-2004 |
≥ 12,000 |
18 |
20.0 x 300 |
0.02 % NaN3 aq. |
SB-804 HQ |
F6516015 |
OHpak SB-2005 |
≥ 12,000 |
20 |
20.0 x 300 |
0.02 % NaN3 aq. |
SB-805 HQ |
F6516016 |
OHpak SB-2006 |
≥ 12,000 |
20 |
20.0 x 300 |
0.02 % NaN3 aq. |
SB-806 HQ |
F6516017 |
OHpak SB-2006M |
≥ 12,000 |
20 |
20.0 x 300 |
0.02 % NaN3 aq. |
SB-806M HQ |
F6709555 |
OHpak SB-G 8B |
(guard column) |
18 |
8.0 x 50 |
0.02 % NaN3 aq. |
(guard column) |
GFC columns to be used with light scattering detector | Standard columns | Base Material: Polyhydroxymethacrylate |
Product Code |
Product Name |
Plate Number
(TP/column) |
Particle Size
(μm) |
Pore Size
(Å) |
Column Size (mm)
I.D. x Length |
Shipping Solvent |
F6429206 |
OHpak LB-802.5 |
≥ 16,000 |
6 |
200 |
8.0 x 300 |
H2O |
F6429201 |
OHpak LB-803 |
≥ 16,000 |
6 |
800 |
8.0 x 300 |
H2O |
F6429204 |
OHpak LB-804 |
≥ 16,000 |
10 |
2,000 |
8.0 x 300 |
H2O |
F6429203 |
OHpak LB-805 |
≥ 12,000 |
13 |
7,000 |
8.0 x 300 |
H2O |
F6429205 |
OHpak LB-806 |
≥ 12,000 |
13 |
15,000 |
8.0 x 300 |
H2O |
F6429202 |
OHpak LB-806M |
≥ 12,000 |
13 |
15,000 |
8.0 x 300 |
H2O |
F6709434 |
OHpak LB-G 6B |
(guard column) |
13 |
- |
6.0 x 50 |
H2O |