Welcome, Sign In First time visitor? Create a New Account
Your cart is empty

Shodex HPLC Column PROTEIN LW-G 6B ID 6mm L 50mm - F6700133

Price: £437.15


Qty. 
+-
Download Data Sheet

Aqueous SEC (GFC) Columns: Silica-based

PROTEIN LW columns separation by size also for high molecular weight
The silica-based SEC (GFC) column for proteins and enzymes

PROTEIN LW-G 6B | 6.0 x 50 mm HPLC Standard Guard Column for antibody drugs analysis

Shodex Product Number: F6700133

Specifications:

Description PROTEIN LW-G 6B 50x6.0mm
Chemistry Producers Term LW
Mode of Separation Aqueous SEC Gel Filtration (GFC)
Functional group Hydroxyl
Gel material Silica
Plates per column (guard)
Housing material steel
Temperature range 4 to 45°C
pH range 3.0 to 7.5
Salt concentration ≤ 0.3 M
Shipping solvent H2O
USP L20, L33, L59
Internal Diameter 8 mm
Length 300 mm
Brand PROTEIN
Particle Size 3 µm

PROTEIN LW-803 and LW-403 4D

More and more monoclonal antibodies (mAb) are used for therapeutic drugs. The pore size of the Shodex PROTEIN LW-803 and LW-403 4D is suitable for this analysis.

  • Silica-based packed columns for aqueous SEC (GFC) analysis
  • Pore size specifically controlled for analyzing proteins with a molecular weight of several hundred of thousand
  • High performance analysis of antibody drugs and various proteins
  • High lot-to-lot reproducibility
  • USP L20 - Dihydroxypropane groups chemically bonded to porous silica or hybrid particles, 1.5-10 μm in diameter, or a monolithic silica rod.
  • USP L33 - Packing having the capacity to separate dextrans by molecular size over a range of 4,000 to 500,000 Da. It is spherical, silica-based, and processed to provide pH stability.
  • USP L59 - Packing for the size-exclusion separations of proteins (separation by molecular weight) over the range of 5 to 7000 kDa. The packing is a spherical 1.5- to 10-μm, silica or hybrid packing with a hydrophilic coating.

Aqueous SEC (GFC) Columns For antibody drugs analysis 

Standard columns | Base Material: Silica | Usable pH Range: pH 3.0 - 7.5

Product Code Product Name * Plate Number
(TP/column)
Particle Size
(μm)
Pore Size
(Å)
Column Size (mm)
I.D. x Length
Shipping Solvent
F6989303 PROTEIN LW-803 ≥ 12,000 3 1,000 8.0 x 300 H2O
F6700133 PROTEIN LW-G 6B (guard column) 3 6.0 x 50 H2O

* Measured with bovine serum albumin

Semi-micro columns | Base Material: Silica | Usable pH Range: pH 3.0 - 7.5

Product Code Product Name * Plate Number
(TP/column)
Particle Size
(μm)
Pore Size
(Å)
Column Size (mm)
I.D. x Length
Shipping Solvent
F6989403 PROTEIN LW-403 4D ≥ 11,000 1.9 1,000 4.6 x 150 H2O
F6700134 PROTEIN LS-G 4J (guard column) 1.9 - 4.6 x 20 H2O

LW-403 4D is recommended to be used with semi-micro type devices
* Measured with bovine serum albumin


  • Model: F6700133
  • Manufactured by: Showa Denko