Shodex HPLC Column HILICpak VT-50 2D ID 2mm L 150mm - F7630400

Price: £1,569.96


Qty. 
+-
Download Data Sheet

HILICpak VT-50 column with quaternary ammonium groups

HILICpak VT-50 2D Semi-micro HPLC Column - 5μm - 2.0mm I.D. x 150mm Length

Shodex Product Number: F7630400

The robust HILIC column for anionic substances (especially phosphate compounds)

Specifications:

Description HILICpak VT-50 2D 150x2.0mm
Quantity 1 pc
Chemistry Producers Term VT
Functional group Quaternary ammonium
Gel material Polyvinyl alcohol
Mode of Separation Polymer-based Hydrophilic Interaction Chromatography HILIC / Ion exchange
Plates per column ≥ 4,500
Maximum pressure 10 MPa (100 bar)
Housing material PEEK
Usual flow rate 0.2 to 0.3 mL/min
Maximum flow rate 0.5 mL/min
Temperature range 4 to 60°C
pH range 2 to 13
Shipping solvent 25 mM HCOONH4 aq./CH3CN = 15/85
Internal Diameter 2.0 mm
Length 150 mm
Brand HILICpak
Particle Size 5 µm
Pore Size 100 Å
  • Suitable for anionic substances (especially phosphate compounds) analysis using HILIC mode
  • Use of some eluents add ion exchange mode
  • Polymer-based packing material provides excellent chemical stability and minimum deterioration over an extended time period
  • Suitable for LC/MS analysis
  • Suitable for: Acidic sugars - Ion exchange | Drugs Metabolites - HILIC | Water-soluble vitamins - HILIC |  Hormones / Neurotransmitters - HILIC 

Possibe Application:

Glyphosate analysis with HILICpak VT-50 column

Organophosphate herbicides such as glyphosate and glufosinate are globally used non-selective weed killer, effective for most weeds. Most countries set regulations for organophosphate herbicides use due to concerns on their toxicity to humans. Therefore, monitoring their concentrations in environment and foods are required. Those compounds are highly hydrophilic, and thus HPLC is a preferred analysis method. However, they are hardly retained under reversed phase mode. To compromise the problem, methods using pre-column derivatization or addition of ion-pair reagent to the eluent are often applied.

In this application, HILICpak VT-50 2D, a polymer-based HILIC mode column, was used under alkaline condition. The results demonstrated the method’s feasibility for the simultaneous LC/MS/MS analysis of glyphosate, glyfosinate, and their metabolites, as well as ethephon, a plant growth regulator which has similar structure to glyphosate. The method proved to provide 1 ng/mL level quantification of the compounds. The method developed here provides a simple and highly sensitive analysis without the use of derivatization nor use of ion-pair reagent. The pH of the eluent used was about 9, thus the system needs to be alkaline tolerant. The use of alkaline eluent improves the peak shape (less tailing) of glyphosate than using an acidic condition. Note that these phosphorus containing pesticides have tendencies of forming metal coordination compounds, therefore select PEEK materials for the flow-line after the injector wherever it's possible.

VG-50 Series - Base Material: Polyvinyl alcohol

Product Code Product Name Plate Number (TP/column) Functional Group Particle Size
(μm)
Pore Size
(Å)
Column Size (mm)
I.D. x Length
Shipping Solvent
Standard columns (Housing Material: SUS)
F7630200 HILICpak VG-50 4D ≥ 5,500 Amino 5 100 4.6 x 150 H2O/CH3CN = 20/80
F7630100 HILICpak VG-50 4E ≥ 7,500 Amino 5 100 4.6 x 250 H2O/CH3CN = 20/80
F6711100 HILICpak VG-50G 4A (guard column) Amino 5 100 4.6 x 10 H2O/CH3CN = 20/80
Semi-micro columns (Housing Material: PEEK)
F7630300 HILICpak VG-50 2D ≥ 3,500 Amino 5 100 2.0 x 150 H2O/CH3CN = 15/85
F6711200 HILICpak VG-50G 2A (guard column) Amino 5 100 2.0 x 10 H2O/CH3CN = 15/85

VT-50 Semi-micro columns (Housing Material: PEEK) - Base Material: Polyvinyl alcohol

Product Code Product Name Plate Number
(TP/column)
Functional Group Particle Size
(μm)
Pore Size
(Å)
Column Size (mm)
I.D. x Length
Shipping Solvent
F7630400 HILICpak VT-50 2D ≥ 4,500 Quaternary
ammonium
5 100 2.0 x 150 25 mM HCOONH4 aq./
CH3CN = 15/85
F6711300 HILICpak VT-50G 2A (guard column) Quaternary
ammonium
5 100 2.0 x 10 25 mM HCOONH4 aq./
CH3CN = 15/85

VC-50 Semi-micro columns (Housing Material: PEEK) - Base Material: Polyvinyl alcohol

Product Code Product Name Plate Number
(TP/column)
Functional Group Particle Size
(μm)
Pore Size
(Å)
Column Size (mm)
I.D. x Length
Shipping Solvent
F7630700 HILICpak VC-50 2D ≥ 3,500 Carboxyl 5 100 2.0 x 150 H2O
F6711600 HILICpak VC-50G 2A (guard column) Carboxyl 5 100 2.0 x 10 H2O

VN-50 - Base Material: Polyvinyl alcohol

Product Code Product Name Plate Number
(TP/column)
Functional Group Particle Size
(μm)
Column Size (mm)
I.D. x Length
Shipping Solvent
Standard columns (Housing Material: PEEK)
F7630500 HILICpak VN-50 4D ≥ 10,000 Diol 5 4.6 x 150 H2O/CH3CN = 25/75
F6711400 HILICpak VN-50G 4A (guard column) Diol 5 4.6 x 10 H2O/CH3CN = 25/75
Semi-micro columns (Housing Material: PEEK)
F7630600 HILICpak VN-50 2D ≥ 3,500 Diol 5 2.0 x 150 H2O/CH3CN = 25/75
F6711500 HILICpak VN-50G 2A (guard column) Diol 5 2.0 x 10 H2O/CH3CN = 25/75
Preparative columns (Housing Material: SUS) [ Preparative columns are made to order. ]
F6830100 HILICpak VN-50 10E ≥ 11,000 Diol 5 10.0 x 250 H2O/CH3CN = 25/75
F6711400 HILICpak VN-50G 4A (guard column) Diol 5 4.6 x 10 H2O/CH3CN = 25/75

?


  • Model: F7630400
  • Manufactured by: Showa Denko