IC NI-424 and IC I-524A columns with quaternary ammonium
IC I-524A HPLC Standard Column for non-suppressor method - Ion Chromatography - 5μm - 4.6mm I.D. x 100mm Length
Shodex Product Number: F6995240
The Ion Chromatography IC columns for anion analysis
Related Products:
IC IA-G Guard Cartridge Column - F6700400
Specifications:
Description |
IC I-524A 100x4.6mm |
Quantity |
1 pc |
Chemistry Producers Term |
I |
Base Material |
Polyhydroxymethacrylate |
Functional Group |
Quaternary ammonium |
Plate Number (TP/column) |
≥ 2,000 |
Shipping Solvent |
2.5 mM Phthalic acid aq. |
Housing Material |
Steel |
Mode of Separation |
Ion Chromatography / Ion exchange / Anion Analysis |
Internal Diameter |
4.6 mm |
Length |
100 mm |
Brand |
IC |
Particle Size |
12 µm |
USP |
L23 |
IC NI-424 Features
- Ideal for anion non-suppressor methods
- NI-424 provides simultaneous analysis of fluoride and phosphate ions
- Suitable for: Organic acids - Ion exchange | Drugs Metabolites - Ion exchange | Anions - Ion exchange - Inorganic anions analysis (Non-suppressor method) -
IC I-524A Features
- Ideal for anion non-suppressor methods
- I-524A fulfills USP-NF L23 requirements - An anion-exchange resin made of porous polymethacrylate or polyacrylate gel with quartenary ammonium groups, 7-12 μm in size.
- Suitable for: Drugs Metabolites - Ion exchange | Anions - Ion exchange - Inorganic anions analysis (Non-suppressor method)
IC I-524A Possible Applications
- Analysis of Hydrophobic Anions (I-524A)
- Analysis of Pamidronate Disodium According to USP-NF Method (IC I-524A)
- Analysis of Sodium Ibandronate (IC I-524A)
- Analysis of Sodium Risedronate (IC I-524A)
- Analysis of Zoledronic Acid (IC I-524A)
- Anion Standards (1) (I-524A)
- Anion Standards (15) (Comparison of NI-424 and I-524A)
- Anion Standards (2) (I-524A)
- Anion Standards (3) (I-524A)
- Anion Standards (6) (I-524A)
- Anion Standards (7) (Anions and Organic Acids)
- Anion Standards (8) (Eluent : Octanesulfonic Acid and Boric Acid)
- Anions in Beer
- Carbonate and Other Anions (1) (I-524A)
- Chelating Reagents (1) (I-524A)
|
- Chinese Cabbage (I-524A)
- Dynamic Range of Column
- Effects of pH on Retention Time (1) (I-524A)
- Effects of Sample Load on Column Efficiency (1) (I-524A)
- High Sensitive Detection Method for Anions
- Iodic Ion in Urine
- Lithium Tetrafluoroborate (I-524A)
- Milk
- Polyphosphoric Acids (I-524A)
- Polythionic Acids (I-524A)
- River Water (1) (I-524A)
- Sea Water (1) (I-524A)
- Sodium Azide (1) (I-524A)
- Tap Water (3) (I-524A)
- Tap Water (4) (I-524A)
|
Range of Ion Chromatography Columns (Anion Analysis)
Product Code |
Product Name |
Plate Number
(TP/column) |
Functional Group |
Particle Size
(μm) |
Column Size (mm)
I.D. x Length |
Shipping Solvent |
For non-suppressor method | Standard columns | Base Material: Polyhydroxymethacrylate | Housing Material: SUS |
F6995243 |
IC NI-424 |
≥ 5,000 |
Quaternary ammonium |
5 |
4.6 x 100 |
8 mM 4-Hydroxybenzoic acid + 2.8 mM Bis-Tris
+ 2 mM Phenylboronic acid + 0.005 mM CyDTA aq. |
F6709616 |
IC NI-G |
(guard column) |
Quaternary ammonium |
5 |
4.6 x 10 |
8 mM 4-Hydroxybenzoic acid + 2.8 mM Bis-Tris
+ 2 mM Phenylboronic acid + 0.005 mM CyDTA aq. |
F6995240 |
IC I-524A |
≥ 2,000 |
Quaternary ammonium |
12 |
4.6 x 100 |
2.5 mM Phthalic acid aq. |
F6700400 |
IC IA-G |
(guard column) |
Quaternary ammonium |
12 |
4.6 x 10 |
2.5 mM Phthalic acid aq. |
For suppressor method (Sodium carbonate eluent) | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK |
F6995244 |
IC SI-90 4E |
≥ 5,000 |
Quaternary ammonium |
9 |
4.0 x 250 |
1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. |
F6709620 |
IC SI-90G |
(guard column) |
Quaternary ammonium |
9 |
4.6 x 10 |
1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. |
F6995245 |
IC SI-50 4E |
≥ 10,000 |
Quaternary ammonium |
5 |
4.0 x 250 |
1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. |
F6709625 |
IC SI-50G |
(guard column) |
Quaternary ammonium |
5 |
4.6 x 10 |
1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. |
For oxyhalides analysis | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK |
F6995260 |
IC SI-52 4E |
≥ 14,000 |
Quaternary ammonium |
5 |
4.0 x 250 |
3.6 mM Na2CO3 aq. |
F6709626 |
IC SI-92G |
(guard column) |
Quaternary ammonium |
9 |
4.6 x 10 |
3.6 mM Na2CO3 aq. |
For oxyhalides rapid analysis | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK |
F6995290 |
IC SI-35 4D |
≥ 13,000 |
Quaternary ammonium |
3.5 |
4.0 x 150 |
3.6 mM Na2CO3 aq. |
F6709627 |
IC SI-95G |
(guard column) |
Quaternary ammonium |
9 |
4.6 x 10 |
3.6 mM Na2CO3 aq. |
For rapid analysis | Semi-micro columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK |
F6995291 |
IC SI-35 2B |
≥ 4,000 |
Quaternary ammonium |
3.5 |
2.0 x 50 |
1.0 mM Na2CO3 + 2.0 mM NaHCO3 aq. |
For anion suppressor method (Potassium hydroxide eluent) | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK |
F6999361 |
IC SI-36 4D |
≥ 8,500 |
Quaternary ammonium |
3.5 |
4.0 x 150 |
10 mM Na2SO4 aq. |
F6709620 |
IC SI-90G |
(guard column) |
Quaternary ammonium |
9 |
4.6 x 10 |
1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. |
Guard filter for IC SI-35 2B | Removes sample-origin insoluble components. |
F6709720 |
IC SI-2GF |
One holder and one filter |
F6709730 |
IC SI-2GF filter |
3 filters |