IC NI-424 and IC I-524A columns with quaternary ammonium
IC IA-G HPLC Standard Guard Column for non-suppressor method - Ion Chromatography - 12μm - 4.6mm I.D. x 10mm Length
Shodex Product Number: F6700400
The Ion Chromatography IC columns for anion analysis
Related Products:
IC I-524A HPLC Standard Column - F6995240
Specifications:
| Description | IC IA-G 10x4.6mm | 
|---|---|
| Quantity | 1 pc | 
| Chemistry Producers Term | IA | 
| Base Material | Polyhydroxymethacrylate | 
| Plate Number (TP/column) | ≥ 2,000 | 
| Functional Group | Quaternary ammonium | 
| Shipping Solvent | 2.5 mM Phthalic acid aq. | 
| Mode of Separation | Ion Exchange/Exclusion Chromatography | 
| Housing Material | Steel | 
| Internal Diameter | 4.6 mm | 
| Length | 10 mm | 
| Brand | IC | 
| Particle Size | 12 µm | 
IC NI-424 Features
- Ideal for anion non-suppressor methods
- NI-424 provides simultaneous analysis of fluoride and phosphate ions
- Suitable for: Organic acids - Ion exchange | Drugs Metabolites - Ion exchange | Anions - Ion exchange - Inorganic anions analysis (Non-suppressor method) -
IC I-524A Features
- Ideal for anion non-suppressor methods
- I-524A fulfills USP-NF L23 requirements - An anion-exchange resin made of porous polymethacrylate or polyacrylate gel with quartenary ammonium groups, 7-12 μm in size.
- Suitable for: Drugs Metabolites - Ion exchange | Anions - Ion exchange - Inorganic anions analysis (Non-suppressor method)
IC I-524A Possible Applications
| 
 | 
 | 
Range of Ion Chromatography Columns (Anion Analysis)
| Product Code | Product Name | Plate Number (TP/column) | Functional Group | Particle Size (μm) | Column Size (mm) I.D. x Length | Shipping Solvent | 
| For non-suppressor method | Standard columns | Base Material: Polyhydroxymethacrylate | Housing Material: SUS | ||||||
| F6995243 | IC NI-424 | ≥ 5,000 | Quaternary ammonium | 5 | 4.6 x 100 | 8 mM 4-Hydroxybenzoic acid + 2.8 mM Bis-Tris + 2 mM Phenylboronic acid + 0.005 mM CyDTA aq. | 
| F6709616 | IC NI-G | (guard column) | Quaternary ammonium | 5 | 4.6 x 10 | 8 mM 4-Hydroxybenzoic acid + 2.8 mM Bis-Tris + 2 mM Phenylboronic acid + 0.005 mM CyDTA aq. | 
| F6995240 | IC I-524A | ≥ 2,000 | Quaternary ammonium | 12 | 4.6 x 100 | 2.5 mM Phthalic acid aq. | 
| F6700400 | IC IA-G | (guard column) | Quaternary ammonium | 12 | 4.6 x 10 | 2.5 mM Phthalic acid aq. | 
| For suppressor method (Sodium carbonate eluent) | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK | ||||||
| F6995244 | IC SI-90 4E | ≥ 5,000 | Quaternary ammonium | 9 | 4.0 x 250 | 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. | 
| F6709620 | IC SI-90G | (guard column) | Quaternary ammonium | 9 | 4.6 x 10 | 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. | 
| F6995245 | IC SI-50 4E | ≥ 10,000 | Quaternary ammonium | 5 | 4.0 x 250 | 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. | 
| F6709625 | IC SI-50G | (guard column) | Quaternary ammonium | 5 | 4.6 x 10 | 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. | 
| For oxyhalides analysis | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK | ||||||
| F6995260 | IC SI-52 4E | ≥ 14,000 | Quaternary ammonium | 5 | 4.0 x 250 | 3.6 mM Na2CO3 aq. | 
| F6709626 | IC SI-92G | (guard column) | Quaternary ammonium | 9 | 4.6 x 10 | 3.6 mM Na2CO3 aq. | 
| For oxyhalides rapid analysis | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK | ||||||
| F6995290 | IC SI-35 4D | ≥ 13,000 | Quaternary ammonium | 3.5 | 4.0 x 150 | 3.6 mM Na2CO3 aq. | 
| F6709627 | IC SI-95G | (guard column) | Quaternary ammonium | 9 | 4.6 x 10 | 3.6 mM Na2CO3 aq. | 
| For rapid analysis | Semi-micro columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK | ||||||
| F6995291 | IC SI-35 2B | ≥ 4,000 | Quaternary ammonium | 3.5 | 2.0 x 50 | 1.0 mM Na2CO3 + 2.0 mM NaHCO3 aq. | 
| For anion suppressor method (Potassium hydroxide eluent) | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK | ||||||
| F6999361 | IC SI-36 4D | ≥ 8,500 | Quaternary ammonium | 3.5 | 4.0 x 150 | 10 mM Na2SO4 aq. | 
| F6709620 | IC SI-90G | (guard column) | Quaternary ammonium | 9 | 4.6 x 10 | 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. | 
| Guard filter for IC SI-35 2B | Removes sample-origin insoluble components. | ||||||
| F6709720 | IC SI-2GF | One holder and one filter | ||||
| F6709730 | IC SI-2GF filter | 3 filters | ||||
- Model: F6700400
- Manufactured by: Showa Denko

 
					
											 
	
     
    



















