IC NI-424 and IC I-524A columns with quaternary ammonium
IC NI-424 HPLC Standard Column for non-suppressor method - Ion Chromatography - 5μm - 4.6mm I.D. x 100mm Length
Shodex Product Number: F6995243
The Ion Chromatography IC columns for anion analysis
Related Products:
IC NI-G Guard Cartridge Column - F6709616
Specifications:
Description | IC NI-424 100x4.6mm |
---|---|
Quantity | 1 pc |
Chemistry Producers Term | NI |
Base Material | Polyhydroxymethacrylate |
Functional Group | Quaternary ammonium |
Mode of Separation | Ion Chromatography / Anion Analysis |
Plate Number (TP/column) | ≥ 5,000 |
Particle Size (μm) | 5 |
Shipping Solvent | 8 mM 4-Hydroxybenzoic acid + 2.8 mM Bis-Tris + 2 mM Phenylboronic acid + 0.005 mM CyDTA aq. |
Housing Material | Steel |
Internal Diameter | 4.6 mm |
Length | 100 mm |
Brand | IC |
Features
IC NI-424
- Ideal for anion non-suppressor methods
- NI-424 provides simultaneous analysis of fluoride and phosphate ions
- Suitable for: Organic acids - Ion exchange | Drugs Metabolites - Ion exchange | Anions - Ion exchange - Inorganic anions analysis (Non-suppressor method) -
IC I-524A
- Ideal for anion non-suppressor methods
IC NI-424 Possible Applications
- Analysis of Alkyl Sulfonic Acids (1) (NI-424)
- Analysis of Chloride According to Japanese Testing Methods for Fertilizers (NI-424)
- Analysis of Pyrophosphate and Tripolyphosphate
- Analysis of Sulfamic Acid and Ammonium Thiocyanate According to Japanese Testing Methods for Fertilizers (NI-424)
- Anion Analysis in Lithium Salts (1) (NI-424)
- Anion Standards (15) (Comparison of NI-424 and I-524A)
- Anion Standards (16) (NI-424: Phthalic Acid aq. Eluent)
- Anion Standards (17) (Hydrophobic Inorganic Ions)
- Anion Standards (18) (NI-424)
- Anions and Organic Acids (NI-424)
- Calibration Curves for Low Concentration F-
- Carbonate and Other Anions (2) (NI-424)
- Chelating Reagents (2) (NI-424)
- Effects of pH on Retention Time (NI-424)
- Effects of Sample Load on Column Efficiency (4) (NI-424)
- Elution Volume of Organic Acids (NI-424)
- Linearity of Calibration Curves (NI-424)
- Methanesulfonic Acid and Methanedisulfonic Acid (NI-424)
- Phosphonates
- Rain Water
- River Water (3) (NI-424)
- Tap Water (7) (NI-424)
Range of Ion Chromatography Columns (Anion Analysis)
Product Code | Product Name | Plate Number (TP/column) |
Functional Group | Particle Size (μm) |
Column Size (mm) I.D. x Length |
Shipping Solvent |
For non-suppressor method | Standard columns | Base Material: Polyhydroxymethacrylate | Housing Material: SUS | ||||||
F6995243 | IC NI-424 | ≥ 5,000 | Quaternary ammonium | 5 | 4.6 x 100 | 8 mM 4-Hydroxybenzoic acid + 2.8 mM Bis-Tris + 2 mM Phenylboronic acid + 0.005 mM CyDTA aq. |
F6709616 | IC NI-G | (guard column) | Quaternary ammonium | 5 | 4.6 x 10 | 8 mM 4-Hydroxybenzoic acid + 2.8 mM Bis-Tris + 2 mM Phenylboronic acid + 0.005 mM CyDTA aq. |
F6995240 | IC I-524A | ≥ 2,000 | Quaternary ammonium | 12 | 4.6 x 100 | 2.5 mM Phthalic acid aq. |
F6700400 | IC IA-G | (guard column) | Quaternary ammonium | 12 | 4.6 x 10 | 2.5 mM Phthalic acid aq. |
For suppressor method (Sodium carbonate eluent) | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK | ||||||
F6995244 | IC SI-90 4E | ≥ 5,000 | Quaternary ammonium | 9 | 4.0 x 250 | 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. |
F6709620 | IC SI-90G | (guard column) | Quaternary ammonium | 9 | 4.6 x 10 | 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. |
F6995245 | IC SI-50 4E | ≥ 10,000 | Quaternary ammonium | 5 | 4.0 x 250 | 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. |
F6709625 | IC SI-50G | (guard column) | Quaternary ammonium | 5 | 4.6 x 10 | 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. |
For oxyhalides analysis | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK | ||||||
F6995260 | IC SI-52 4E | ≥ 14,000 | Quaternary ammonium | 5 | 4.0 x 250 | 3.6 mM Na2CO3 aq. |
F6709626 | IC SI-92G | (guard column) | Quaternary ammonium | 9 | 4.6 x 10 | 3.6 mM Na2CO3 aq. |
For oxyhalides rapid analysis | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK | ||||||
F6995290 | IC SI-35 4D | ≥ 13,000 | Quaternary ammonium | 3.5 | 4.0 x 150 | 3.6 mM Na2CO3 aq. |
F6709627 | IC SI-95G | (guard column) | Quaternary ammonium | 9 | 4.6 x 10 | 3.6 mM Na2CO3 aq. |
For rapid analysis | Semi-micro columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK | ||||||
F6995291 | IC SI-35 2B | ≥ 4,000 | Quaternary ammonium | 3.5 | 2.0 x 50 | 1.0 mM Na2CO3 + 2.0 mM NaHCO3 aq. |
For anion suppressor method (Potassium hydroxide eluent) | Standard columns | Base Material: Polyvinyl alcohol | Housing Material: PEEK | ||||||
F6999361 | IC SI-36 4D | ≥ 8,500 | Quaternary ammonium | 3.5 | 4.0 x 150 | 10 mM Na2SO4 aq. |
F6709620 | IC SI-90G | (guard column) | Quaternary ammonium | 9 | 4.6 x 10 | 1.8 mM Na2CO3 + 1.7 mM NaHCO3 aq. |
Guard filter for IC SI-35 2B | Removes sample-origin insoluble components. | ||||||
F6709720 | IC SI-2GF | One holder and one filter | ||||
F6709730 | IC SI-2GF filter | 3 filters |
- Model: F6995243
- Manufactured by: Showa Denko