Sensitivity, reliability, and simplicity combined3465 Electrochemical Detector

The Waters 3465 Electrochemical Detector combines sensitivity, reliability, and simplicity for electrochemical detection. Its versatile detection modes are ideally suited for analyzing a wide range of compounds.

The 3465 Electrochemical Detector’s multiple flow cell configuration combines working and reference electrode designs to minimize cost and enhance flexibility. The flow cell accommodates several reference electrodes: ISAAC; traditional salt-bridge design, which limits air bubble formation; and Hy-Ref, which is ideal for carbohydrate analysis and is compatible with extreme mobile phases. The detector is designed for ultra-trace analysis and is compatible with both analytical and microbore scale applications.

Overview

  • Selectivity for a wide range of applications such as catecholamines, aminoglycosides, carbohydrates, neurotransmitters, phenols, and thiols with multiple flow cell, electrode, and detection mode options
  • Sensitivity for ultra-trace analysis to detect concentrations as low as 10 ρmol/L and as high as µmol/L
  • Simplicity of operation plus versatility with Empower control and use with the Waters liquid chromatography (LC) portfolio
  • Reliability backed by Waters service and application support and 21CFR Part 11 compliance readiness

Recommended Use: For ultra-trace analysis compatible with both analytical and microbore scale applications.

Advanced sensitivity

  • Achieve ultra-trace analysis
  • Eliminate matrix interferences with an Advanced Digital Filter
  • Improve thermal operating stability with Faraday-shielded oven

Overlay of chromatograms of 0.008 mg/mL kanamycin sulfate and 0.020 mg/mL amikacin obtained in a USP specified mobile phase (n=4).

Overlay of chromatograms of 0.008 mg/mL kanamycin sulfate and 0.020 mg/mL amikacin obtained in a USP specified mobile phase (n=4).

Flexible for your requirements

The 3465 is controlled by industry-leading Empower Chromatography Data System (CDS) and compatible with the Arc HPLC, Alliance, ACQUITY Arc, and ACQUITY UPLC H-Class Systems, 1515 isocratic and gradient Empower CDS-based systems, Breeze, and QS-based systems when configured with an eSat/IN analog/Digital convertor. There are two configurations of the 3465 ECD: one supports control of a single flow cell and the second supports the independent control of dual flow cells.

Specifications:

OPERATING SPECIFICATIONS
Operating modes Direct Current (DC), DC, PULSE, PULSE 2, SCAN (DC, PULSE, and PULSE 2 are available and supported under Empower CDS control)
Other modes CONFIG, DIAG, and SERVICE
Detector configurations Single Flow Cell (SCC) (p/n: 725000673) or Dual Flow Cell (DCC) (p/n: 725000686)
Autozero Triggered by keyboard, rear panel TTL, or remote PC control (LAN)
Max. current compensation (Autozero) 25 nA - 2.5 mA in DC and PULSE mode dependent on range setting
Offset +50% to -50% of max. output voltage, 5% steps
PC control Parametric control and data-acquisition via LAN port (USB service port)
Acquisition control .Net Driver for Empower 3, leveraging existing Empower 3 ICF Support layer
Analog signal output (DAC) -1 to +1 V full scale (via 16-bit D/A converter)
Analog output (I/E) -2.5 to +2.5 V full scale (unprocessed I/E converter signal)
Digital I/O connectors (rear panel) 2x relay, 5x TTL outputs (CMOS 3.3V logic), 13 TTL inputs (programmable), 1x GND
Programmable I/O functionality Cell on, Cell off, Autozero, Start, Overload, Relay, Auxiliary
Integrated flow cell and column heating compartment +7 °C above ambient to 60 °C, accuracy 0.5 °C, stability 0.1 °C; accommodates column and flow cell(s)
Flow cell Confined wall-jet design - VT03, Sencell, and thin-layer design Flexcell
VT03 Flow cell (originally available with 2465 ECD); available with 2- and 3-mm working electrode diameter
Sencell Tool-free adjustable spacer; multiple working and reference electrodes
Flexcell Replaceable working electrode, (GC, Pt, Au, Ag, BDD) stainless steel auxiliary electrode
DC MODE
Range 10 pA - 200 µA in 1, 2, or 5 increments
Filter (ADF) 10 - 0.001 Hz in 1, 2, or 5 increments; RAW and OFF: For unprocessed data
Potential (Ec) -2.5 V to +2.5 V with 10 mV increments
Data rate 1 - 100 Hz in 1, 2, or 5 increments, dependent on filter setting
Noise <2 pA with dummy cell (load of 300 MΩ/470 pF) in 1 nA range, filter off, Ec +800 mV, and temp. of 35 °C
PULSE MODE
Range 10 nA - 200 µA in 1, 2, or 5 increments
Filter (ADF) 0.5 - 0.001 Hz in 1, 2, or 5 increments; OFF: For unprocessed data
Potential (Ec) -2.5 V to +2.5 V with 10 mV increments
Data rate 1/(pulse duration) Hz
Waveform Max five potential steps
Pulse times (t1-t2) t1: 100 ms - 2000 ms; t2, t3, t4, and t5: 0 - 2000 ms in 10 ms increments
Sampling times (ts) 20 ms – [t1 – 60] ms
PULSE MODE 2
Range 10 nA - 200 µA in 1, 2, or 5 increments
Filter (ADF) 0.5 - 0.01 Hz in 1, 2, or 5 increments; OFF: for unprocessed data
Potential (Ec) -2.5 V to +2.5 V with 10 mV increments
Data rate 1/(pulse duration) Hz
Waveform Free programmable multi-step waveform with up to 30 time-potential (t, E) coordinates and max pulse duration of 4 s; time points in 10-ms increments
Sampling time Sampling interval is freely programmable, defined by Begin and End markers
SCAN MODE
Range 10 nA - 200 µA in 1, 2, or 5 increments
Potential (Ec) -2.5 V to +2.5 V with 10 mV increments
Data rate 1 Hz
Scan rate 1 - 100 mV/s in 1, 2, or 5 increments
Cycle Half, Full, or Continuous
ENVIRONMENTAL SPECIFICATIONS
Usage For indoor use only
Solvent storage <2000 m
Operating temp. range 10 – 35 °C
Operating humidity range 20% to 80% RH
ELECTRICAL SPECIFICATIONS
Voltage range 100-240 VAC autosensing
Voltage fluctuation Input voltage of 100-240 VAC +/- 10%†
Line frequency 50-60 Hz
Power requirements 260 VA
† Derating may be needed under low input voltages
PHYSICAL SPECIFICATIONS
Weight 14.4 Kg (32 lbs.) without flow cell or column (SSC version)
Width 22 cm (8.7 “)
Height 44 cm (17.3 “)
Depth 43 cm (16.9 “)
Safety and EMC compliance CE (CB Scheme), UL, and CSA (cMETus approval)
Audible noise 45 dBA (detector on and the door closed)
ORDERING INFORMATION
Description Part Number
3465 Electrochemical Detector 725000673
3465 Dual Flow Cell Electrochemical Detector 725000686
Flowcell 2-mm Glassy Carbon WE/Salt Bridge Ref (used for qualification) 700013052
Flowcell Kit, 2-mm Glassy Carbon WE/ISAAC REF, VT03 (used for qualification) 205004215

 


  • Model: 3465 Electrochemical Detector
  • Manufactured by: Waters