Part Number: ACE-1010-10005
Title: Avantor® ACE® C18-PFP Microbore HPLC Column, 2 µm, 100 Å, 0.5 x 100 mm, 1pk - ACE-1010-10005
Avantor® ACE® C18-PFP phase utilises a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 µm to 10 µm) and complementary phases
- Also useful for analytes with π-bonding or electron or proton donor groups
- Ultra-low bleed to ensure LC/MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
Due to its integral pentafluorophenyl functionality, Avantor® ACE® C18-PFP is also recommended for separations that involve halogenated aromatic compounds, regioisomers, and those analytes with differing shape constraints.
Max. pressure: 400 bar
Title: Avantor® ACE® C18-PFP Microbore HPLC Column, 2 µm, 100 Å, 0.5 x 100 mm, 1pk - ACE-1010-10005
Avantor® ACE® C18-PFP phase utilises a specially developed ligand combining a C18 chain with integral PFP functionality. This results in a phase that maintains the hydrophobic, stability and low bleed characteristics of leading C18 phases, yet provides the multiple retention mechanisms of a PFP phase.
- Ultra-high purity, base deactivated silica with exceptional reproducibility
- Ideal for a wide range of analytes differing in hydrophobicity
- Wide range of particle sizes (1.7 µm to 10 µm) and complementary phases
- Also useful for analytes with π-bonding or electron or proton donor groups
- Ultra-low bleed to ensure LC/MS compatibility
- Method validation kits contain three different batches of the same phase - available on request
Due to its integral pentafluorophenyl functionality, Avantor® ACE® C18-PFP is also recommended for separations that involve halogenated aromatic compounds, regioisomers, and those analytes with differing shape constraints.
Max. pressure: 400 bar
Specifications:
Column format | Microbore |
Phase | C18-PFP |
Pore size | 100 Å |
Particle size | 2 µm |
Ø int. | 0.50 mm |
Length | 100 mm |
Connection | 1/16" connection |
Pk | 1 |
P/N | ACE-1010-10005 |
Carbon load | 14.3% |
Endcapped | Yes |
Max. pressure | 400 bar |
pH range | 2 - 8 |
Surface area | 300 m²/g |
USP code | L1 |
- Model: ACE-1010-10005
- Manufactured by: Avantor