Intrada Amino Acid LC-MS Columns
Amino Acids Separation Column for LC-MS
Imtakt Product Number: WAA24
Column Specifications:
ID: | 2mm |
Length: | 100mm |
Particle Size (Microns): | 3µm |
Pressure: | Up to 250 bar / 3500 psi |
The world’s 1st specialty column for intact amino acid analysis via LC-MS
- LC-MS analysis of amino acids
- Amino Acid Analysis - No derivatization required
- Ability to separate isobaric amino acids such as Leu and Ile
- High-throughput (< 1 minute) analysis for selected amino acids
- 5-10 minutes for protein amino acids analysis
- Pure spherical silica / 3um particles / unique stationary phase designed for amino acid
Imtakt has developed a novel column for the analysis of amino acids with LC-MS systems. The Intrada Amino Acid column achieves high-throughput analysis without tedious pre- or post-labeling methods. Optimization of analytical run times and resolution is accomplished by varying column dimensions. Separation of leucine and isoleucine isomers, GABA isomers, and dipeptide analysis is now possible without derivatization.
LC-MS analysis for 55 amino acids in 10 minutes
- New stationary phase designed specifically for optimal amino acid and dipeptide separation
- No pre- or post-labeling methods required
- High throughput analysis via LC-MS
- Separation of isobaric amino acids on LC-MS systems is finally possible
Various column dimensions enhance scalability and flexibility
- Mobile phase composition and gradient method can be optimized for sensitivity requirements and run times.
- Use of a shorter column allows for one minute analysis of non-isomer amino acids.
Column Recommendations
- The Intrada Amino Acid column should be used only with LC-MS systems to achieve adequate peak identification.
- This product is not recommended for applications involving UV or ELSD instruments
- Detection sensitivity is highly dependent upon MS instrument performance. LC-MS instruments should be carefully chosen to yield adequately sensitive data.
- Analysis of longer chain peptides that require high ionic strength mobile phases should use the Scherzo SS-C18 multi-mode ODS column.
- Please refer to the instruction packet for sample preparation procedures.
Intrada Amino Acid high-throughput columns provide amazing speed, selectivity, and convenience. The next generation amino acid analysis method for clinical amino acid biomarkers, fermented materials, botanical amino acids is here!
Intrada Amino Acid is an excellent choice for the analysis of polar dipeptides, which are notoriously difficult to retain and separate in conventional HPLC.
Range of Intrada Amino Acid
3µm Column, Pressure limits of up to: 20MPa, 250 bar, 3,000 psi
Product Number | |||||||
Column Length (mm) | Analytical | Semi-prep | |||||
1.0 mm I.D. | 1.5 mm I.D. | 2.0 mm I.D. | 3.0 mm I.D. | 4.6 mm I.D. | 6.0 mm I.D. | 10.0 mm I.D. | |
10 | WAA20 | WAA30 | |||||
20 | WAA29 | WAA39 | |||||
30 | WAA11 | WAA21 | WAA31 | ||||
50 | WAA12 | WAA22 | WAA32 | ||||
75 | WAA13 | WAA23 | WAA33 | ||||
100 | WAA14 | WAA24 | WAA34 | ||||
150 | WAA15 | WAA25 | WAA35 | ||||
250 | WAA16 | WAA26 | WAA36 |
All stationary phases can also be made in the following additional internal diameters: Nano: 0.05mm, 0.075mm Capillary: 0.1mm, 0.3mm, 0.5mm, Please Contact our Sales Team with your specifications.
Additional Imtakt Columns Available
- Model: WAA24
- Manufactured by: Imtakt