HT4150L: Cell Washer (RUO) Sample Preparation Workstation
HTA HT4150L Cell Washer (RUO) Sample Preparation Workstation
Automate Your Flow Cytometer Sample Preparation
LYSE • WASH • ISOLATE CELLS • CHANGE BUFFER
This product is only available in selected countries
The HT4150L cell washer is an automated device for preparing cells for subsequent cytofluorimetric analysis. The HT4150L is designed to provide thorough and reproducible cell lysis, separation, and fractioning through a built-in cytocentrifuge specifically designed for this purpose.
Key Features
Automate your lysis-wash workflow
HT4150L can hold up to 32 standard sample tubes, which are processed in two batches of 16 samples each. When performed manually, this kind of cell preparation is laborious, tedious, and prone to variability. On the other hand, the automation of this workflow allows for protocol standardisation, consistent operations, and minimal labour.
Haematology studies
Typical use involves the manipulation of peripheral blood to isolate leucocytes marked with fluorochrome-conjugated antibodies. After the markers are added to the whole blood specimen, HT4150L automates the adding of the lysing solution to allow arthrolysis to occur. A centrifugation step allows for the precipitation of white blood cells: red cell debris, platelets, unbound antibodies, and residual proteins remain in the supernatant and are automatically removed. WBC can, indeed, be washed and then resuspended to be further analyzed by a flow cytometer.
User friendly
With the integrated touch screen, you can start sample processing in a few taps: you will experience simple and user-friendly control. Large reagent reservoirs and a waste tank are included for extended operations. Sensors that detect a lack of reagents and fullness of waste tank are included for a better user experience.
Flexible and straight forward operations
The automated syringe draws a pre-set quantity of lysing solution, afterwards, the tube is automatically picked up and put in the cytocentrifuge, which realizes the separation. Then the device removes the supernatant and the buffer solution is added to the pellet to resuspend cells. The cycle is completed by the tube repositioning into its original position in the rack: you will be ready for analysis.
More than a standard lab centrifuge
The built-in centrifuge features rotor position control so that no tubes mismatches happen and automated centrifuge cover to make the centrifuge robot friendly. Furthermore the algorithm that regulates centrifuge acceleration and deceleration during spinning has been fine-tuned to allow for efficient separation/fractioning while preserving the integrity of the precipitated cells.
TECHNICAL SPECIFICATIONS
Sample capacity | |
Tube compatibility: | 12 x 75 mm open tubes |
Total sample capacity: | 32 |
Samples per batch/centrifuge: | 16 |
Fluid capacity | |
Lysing solution: | 250 ml |
Washing solution: | 500 ml |
Performance 1 | |
Accuracy: | deviation of the Subset Percentages compared to manual preparation: ≤5% (typically observed: less than 3%) |
Precision: |
|
WBC Recovery: | After one wash: 91-101% (mean: 97%) After two washes: 80-96% (mean: 88%) |
Typical throughput: |
|
Method properties | |
Modes: | lysis only |
washing only | |
lysis & washing | |
double lysis | |
Lysis parameters | |
Lysis source: | buffer, lysing solution |
Lysis volume: | 1-2.5 ml with 0.1 ml steps |
Lysis time: | 0-99 minutes with 1 minute steps |
Washing parameters | |
Centrifuge cycles: | 1-9 washing cycles |
Centrifuge speed: | 50-300g in 50g steps |
Centrifuge time: | 1-10 min with 1 min steps |
Final volume: | 0.0-1.9 ml with 0.1 ml steps |
Physical features | |
Dimensions (W x H x D): | 530 x 700 x 780 mm |
Weight | 27 kg |
Power supply: | 100-240±10%Vac; 50-60Hz; 120W |
1 Obtained with reference method 1 (mode: lysis & washing; lysis source: lysing solution; lysis volume: 2ml; lysis time: 15min; centrifuge repetition: 1; centrifuge speed: 250g;
centrifuge time: 3min; final volume: 1ml)
2 Obtained with reference method 2 (the parameters are the same as the method 1, but centrifuge repetition: 2)
- Model: HT4150L
- Manufactured by: HTA