Welcome, Sign In First time visitor? Create a New Account
Your cart is empty

LNI SWISSGAS SONIMIX 2106 Gas Mixer

Price:
Live chat below or contact us for latest price.


Download Data Sheet

SONIMIX 2106 Best in class Gas Mixer with the unique sonic nozzle technology

Available in the Following Configurations:

Sonimix 2106-10 Flow 2.5 Nl/min. 19" Rack casing - 10 points programmable gas divider, 1 range of 10 points.
Flow 5 Nl/min. 19" Rack casing - 10 points programmable gas divider, 1 range of 10 points.
Sonimix 2106-16 Flow 2.5 Nl/min. 19" Rack casing - 16 points programmable gas divider, 1 range of 16 points.
Flow 5 Nl/min. 19" Rack casing - 16 points programmable gas divider, 1 range of 16 points.
Sonimix 2106-64 Flow 2.5 Nl/min. 19" Rack casing - 64 points programmable gas divider, 1 range of 64 points.
Flow 5 Nl/min. 19" Rack casing - 64 points programmable gas divider, 1 range of 64 points.
Sonimix 2106-128 Flow 2.5 Nl/min. 19" Rack casing - 128 points programmable gas divider, 1 mrange of 128points.
Flow 5 Nl/min. 19" Rack casing - 128 points programmable gas divider, 1 range of 128points.
Sonimix 2106-256 Flow 2.5 Nl/min. 19" Rack casing - 256 points programmable gas divider, 1 range of 256 points.
Flow 5 Nl/min. 19" Rack casing - 256 points programmable gas divider, 1 range of 256 points.
Sonimix 2106-512 Flow 2.5 Nl/min. 19" Rack casing - 512 points programmable gas divider, 1 range of 256 points.
Flow 5 Nl/min. 19" Rack casing - 512 points programmable gas divider, 1 mrange of 256 points.
Sonimix 2106-1024 Flow 2.5 Nl/min. 19" Rack casing - 1024 points programmable gas divider, 1 range of 1024 points.
Flow 5 Nl/min. 19" Rack casing - 1024 points programmable gas divider, 1 range of 1024 points.
Sonimix 2106-Predil Flow 2.5 Nl/min. 19" Rack casing - 3 points programmable gas divider,1/10 1/100 and 1/1000.
Flow 5 Nl/min. 19" Rack casing - 3 points programmable gas divider,1/10 1/100 and 1/1000.
Corrosive gases - Flow 2.5 Nl/min. 19" Rack casing - 3 points programmable gas divider,1/10 1/100 and 1/1000.
Corrosive gases - Flow 5 Nl/min. 19" Rack casing - 3 points programmable gas divider,1/10 1/100 and 1/1000.

The Sonimix 2106 is a gas mixer mainly used to calibrate and linearize gas monitors and to generate specific gas mixtures.

The Sonimix 2106 is based on the principle of gas flow through sonic nozzles and is built according the ISO 6145/6 standard. The sonic nozzle principle makes it the most accurate and stable device on the market. It generates binary mixtures from 0 to 100% in fixed steps in a pure mechanical process without electronic regulation and without any influence from ambient pressure or temperature.

The touch-screen LCD interface provides simple and user-friendly management of all functions on the unit.
Optional Auto Diagnostic functions for quick check of the instrument performances (patented) is available.
Optional Nox converter tester.

Proven metrological performances – Optional ISO 17025 calibration reports will be delivered from our accredited laboratory. In this way the device can be easily linked with National Standards (NIST, METAS, UKA, etc).

Product features:

  • Accuracy – (0.5% rel.)/ stability – (0.2% rel.)
  • Range – Up to 1024 programmable calibration points. Rare calibrations need.
  • Return on investment – Reduce gas cylinders costs, less components
  • Compatibility for corrosive gases (% range) with gold nozzles
  • Safe – Smart purge routine
  • Ergonomic with LCD display

Main applications:

  • Fulfilment of ISO 14481 norm CEM (QUAL 1 to QUAL 3)
  • Quality control of gas monitors in the laboratory
  • Gas analysers production
  • To generate accurate gas standards and mixtures for R&D purpose
  • Automotive industry for engine test benches

Options:

  • 6800 00 1xx.10 - Corrosive gases Optional configuration for corrosive gases / Gold Coating
  • 6800 00 3xx.10 - Silconert 2000 coating Silconert 2000 coating
  • 6700 05 103.1 - Additional inlets* Module for 4 additionnal diluted gas inlets (Total 5 Inlets) . Maximum 3 modules by instrument
  • 6800 02 000 - NO2 converter tester* NO2 converter tester 15 to 50 ppm, remote command by RS232. Vacuum to 1 bar rel.
  • 6800 02 001 - NO2 converter tester* NO2 converter tester 30 to 100ppm, remote command by RS232. Vacuum to 1 bar rel.
  • 6800 02 002 - NO2 converter tester* NO2 converter tester 300 to 1000ppm, remote command by RS232. Vacuum to 1 bar rel.
  • 6800 00 5xx.10 - Option portative 50x19x40 cm in stead of the 19 Inch rack casing.
  • 6800 10 000 - Portable casing for casing 19''
  • 6980 00 010 -  ISO 17025 New device Additional cost for ISO17025 calibration for new devices (UKAS, COFRAC, SIT, SAS compatible) (10 dilution pts)

Technical specifications:

Models: Sonimix 2106 2106-10 2106-16 2106-64 2106-128 2106-256 2106-1024
General data
Dilution points 10 16 64 128 256 1024
Dilution principle Sonic nozzles (according ISO 6145-6) and high precision pressure regulators
Dilution gas line flow accuracy < 0.25 % of set point
Source gas line flow accuracy < 0.25 %
Repeatability on flow < 0.1 %
Accuracy on concentration (rel) < 0.5 % on the highest dilution ratio
Repeatability on concentration Better than 0.14% relative
Response time < 15 sec
Auto Diagnostic Diagnostic of pressure regulator, valve opening, nozzle functioning, drift
Factory calibration By laminar flow with uncertainty < 0.2% of reading
Warm up time none
Operating temperature 15°C - 40°C
Dimensions 19" 3HE/84 TE , 500mm deep portable casing in option
Net weight 3 x Swagelok 1/4" (Air, Nitrogen, Span gas), optional up to 3x 4Swagelok 1/4" per instrument
Gas inlet requirments
Dilution gas Requires dry Air, Nitrogen or other gas, 2 ports
Dew point -40°C
Source gas compatible with corrosive gases up to 10% (if option installed), up to 12 ports
Pressure 3 ± 0.3 bar rel
Fittings 3 x Swagelok 1/4" (Air, Nitrogen, Span gas), optional up to 3x 4Swagelok 1/4"
per instrument
Gas outlet requirments
Flow 2.5 ± 0.25 L/min (other flow rate upon request)
adjustable by by-pass valve in front of the instrument
Pressure up to 1 bar rel (other pressure upon request)
Fittings 4 x Swagelok 1/4" (Mixture, Waste, Purge)
Communication
RS 232 Standard
Ethernet TCP/IP Standard
USB Standard
WiFi Optional
Electrical data
Power supply voltage 230V/50-60Hz
115V/60Hz
100V/50-60Hz
Installed power (Max) 150W
NOx converter tester (option)
NO2 range 15 to 50 ppm / 30 to 100 ppm / 300 to 1000 ppm, all at 2.2 NL/min
Stabilization time Less than 1 min (once the device has warmed up)
Inlet fittings 2 x Swagelok (NO, air) 1/4"
Outlet fittings 2 x Swagelok (outlet, purge) 1/4"

  • Model: SX 2106